SciELO - Scientific Electronic Library Online

 
vol.85 issue3Public Health Service Prescriptions of Vaccines not Included in Systematic Vaccination Programs in Valencian Community, Spain, during the Period 2004-2009Comorbidity and Cardiovascular Risk in Subjects with Initial Diagnosis of Hypercholesterolemia author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Española de Salud Pública

On-line version ISSN 2173-9110Print version ISSN 1135-5727

Abstract

CUTANDA HENRIQUEZ, Francisco  and  VARGAS CASTRILLON, Silvia. Impact of a PET/CT Facility in its Community Environment. Rev. Esp. Salud Publica [online]. 2011, vol.85, n.3, pp.297-303. ISSN 2173-9110.

Background: The PET/CT (Positron Emission Tomography/Computed Tomography) technique is currently expanding, with new facilities and indications appearing every year. Being mostly an outpatient technique, patients leave the facility when the study has been performed, although they still retain a certain amount of radiopharmaceutical. Therefore, setting up a PET/CT facility might involve a risk increase for the population. This study aims at estimating this risk. Methods: Comprehensive measurements to estimate dose levels have been carried out in the PET/CT facility at Hospital General Universitario Gregorio Marañón. The population has been distributed into five categories according to their involvement in the studies and their radiation exposure. A quantitative dose estimation has been carried out. Results: The risk associated with a PET/CT facility has been assessed and no risk increase has been detected. Staff dose is shown to be less than 2 μSv per patient, ˜20 μSv for an accompanying person and ˜40 μSv for a relative. Citizens walking along with patients or sharing public transportation with them receive a dose that is below Madrid´s background radiation. Conclusions: Values obtained are well below annual dose limits. Moreover, these results support the outpatient care of this kind of studies, because accompanying persons´ and relatives´ risk is negligible. The impact of a PET/CT facility does not involve an increase in risk for the general population.

Keywords : Radiopharmaceuticals; Positron-Emission Tomography; Tomography X-Ray Computed; Radiation dosage; Fluorodeoxyglucose F18.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License