SciELO - Scientific Electronic Library Online

 
vol.15 número3Validación española de la Escala de Evaluación de la Competencia Docente en Educación Física de secundariaVersión portuguesa de la Escala de Estado de Ansiedad en Educación Física: propiedades psicométricas y su asociación con el sexo, edad y actividad física extracurricular índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Cuadernos de Psicología del Deporte

versión On-line ISSN 1989-5879versión impresa ISSN 1578-8423

Resumen

GOMEZ-JIMENEZ, Fernando et al. Effect of the tester level of experience on the criterion-related validity and inter-session reliability of five different ankle dorsal flexion range of motion measures. CPD [online]. 2015, vol.15, n.3, pp.123-134. ISSN 1989-5879.  https://dx.doi.org/10.4321/S1578-84232015000300012.

The purpose of this study was to analyse the effect of the different degree of tester´s experience on the criterion-related validity and the inter-session reliability of the ankle dorsiflexion range of motion measures (ROMADF) obtained from the following tests: passive non weight-bearing test (ADFPAS), weight-bearing lunge test using an inclinometer (ADFLUN-INC) and a tape measure (ADFLUN-TAP), modified-weight bearing test with a moveable datum (ADFLUN-DAT) and modified weight bearing test with a box (ADFLUN-BOX). A total of 17 recreational athletes completed this study. Each participant was assessed by 2 testers with different level of experience in the clinical setting (expert and novel) of the ROMADF using 5 assessment tests in two different sessions, with a rest-interval of 72-96 hours. The results showed low validity scores for the novel tester in all the assessment tests except for the ADFLUN-INC test (standardized typical error of the estimate = 0.5 [small] and Pearson coefficient = 0.85 [moderate]; Kappa = 0.74 [good]). The expert tester showed high reliability scores for the ADFLUN-INC, ADFLUN-TAP and ADFLUN-BOX tests and acceptable scores for the ADFPAS and ADFLUN-DAT. The novel tester presented acceptable reliability scores for all the assessment tests except for the ADFPAS, which were considered as non-acceptable. Therefore, we recommend that both the expert and novel testers use the ADFLUN-INC test to: (a) identify subjects with restrained or normal ROMADF and (b) monitor the efficacy of the intervention treatments applied in case of being necessary.

Palabras clave : Reproducibility; ankle springs; injury prevention; accuracy of the measure.

        · resumen en Español | Portugués     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons