SciELO - Scientific Electronic Library Online

 
vol.17 número3Monitorización del acceso vascular: parámetros convencionales frente a flujo intraaccesoEvolución del peso en pacientes durante el primer año del trasplante renal índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Enfermería Nefrológica

versão On-line ISSN 2255-3517versão impressa ISSN 2254-2884

Resumo

ARAGO SORROSAL, Sergi et al. Adapted automated peritoneal dialysis: an effective, efficient and safe prescription method. Enferm Nefrol [online]. 2014, vol.17, n.3, pp.202-208. ISSN 2255-3517.  https://dx.doi.org/10.4321/S2254-28842014000300007.

The aim of this study is to analyze results obtained following the introduction of the adapted automated peritoneal dialysis, in a group of patients in conventional automated peritoneal dialysis program using bicarbonate-buffered dialysate. Design trial in experimental phase, which was conducted in the months from February and December 2013, in the unit of peritoneal dialysis in the Hospital Clinic of Barcelona. Study subjects were 12 patients, 7 women and 5 men, in conventional automated peritoneal dialysis modality. Mean age 58±12 years (range: 34-71). The study assessed two automated peritoneal dialysis prescriptions. This study was started with conventional dialysis for three months. Then, dialysis prescription was modified, and adapted was applied during same interval of time. And finally, conventional dialysis for three months. The same total volume of dialysate, the same duration, and the same 1,5% glucose bicarbonate buffered dialysate, were prescribed in both modalities. Only dwell time and fill volume were modified, when dialysis modality was changed. All patients, on dry day. Variables at the beginning of the study, and at each change of prescription were seldom monitored. Outcomes for conventional dialysis: Kt/v=2,3±0,2, creatinine clearance=63±8l/week, and ultrafiltration=842±110ml. For dialysis adapted, Kt/v=2,8±0,2, creatinine clearance=74±9l/week, and ultrafiltration=982±123ml. Adapted dialysis allows appropriate treatment efficiency, improves adequacy of dialysis and ultrafiltration parameters; being safe and comfortable for the patient.

Palavras-chave : Dialysis prescription; peritoneal dialysis efficiency; adapted; volumes; dwell.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons