SciELO - Scientific Electronic Library Online

 
vol.65 número1Evaluación preclínica de la actividad antiinflamatoria de un gel con aceite de árbol de téIdentificación de factores determinantes de falta de adherencia a los antidiabéticos orales en pacientes con diabetes mellitus tipo 2: revisión sistemática índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Ars Pharmaceutica (Internet)

versión On-line ISSN 2340-9894

Resumen

NAYEF, Ali Naser; HUSSAIN, Alaa Frak  y  TAHA, Dakhil Nassir. Neocuproine-based sensitive flow injection method for mefenamic acid determination in aqueous solutions and pharmaceutical formulations. Ars Pharm [online]. 2024, vol.65, n.1, pp.45-55.  Epub 23-Ago-2024. ISSN 2340-9894.  https://dx.doi.org/10.30827/ars.v65i1.28908.

Introduction:

A novel and precise approach is presented for the mefenamic acid (MEF) estimation in pharmaceutical formulations and aqueous solutions, utilizing flow injection spectrophotometry. Similarly, this method demonstrates a high level of sensitivity and accuracy.

Method:

The suggested method is based on the reducing of Cu(II)-2,9DMP complex to coloured Cu(I)- 2,9DMP complex ,by two step of reaction. However, in the first step the reaction is occur between neocuproine and Cu(ΙΙ) to form colorless complex of Cu(II)-2,9DMP, then in second step mefenamic acid reduced the formed colorless complex to Cu(I)- 2,9DMP with yellow orange colour, Flow Injection Method were developed and validated.

Results:

The measurement of the optical density of the yellow-orange substances was conducted at a wavelength of 454 nm. The calibration graphs exhibit linearity within the specified concentration ranges of 1.00-80.00 µg/mL. The detection limit (LOD) is determined to be 0.360 µg/ mL, while the limit of quantification (LOQ) is found to be 1.093 µg/ mL.

Conclusions:

the proposed methodology exhibited notable attributes such as rapidity, sensitivity, and reliability, rendering it suitable for the accurate quantification of (MEF) in pharmaceutical formulations and aqueous solutions in various commercially available formulations.

Palabras clave : Continues Flow İnjection Analysis; Mefenamic Acid; Neocuproine.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )