SciELO - Scientific Electronic Library Online

 
vol.5 issue4Atrial flow regulator and atrial septostomy in pediatric pulmonary hypertension: when procedure and device matchCo-registration assisted 3-vessel orbital atherectomy in de novo calcified multivessel coronary artery disease author indexsubject indexarticles search
Home Pagealphabetic serial listing  

My SciELO

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


REC: Interventional Cardiology

On-line version ISSN 2604-7276Print version ISSN 2604-7306

REC Interv Cardiol ES vol.5 n.4 Madrid Oct./Dec. 2023  Epub Mar 04, 2024

https://dx.doi.org/10.24875/recic.m23000392 

Scientific letters

Coronary malperfusion in acute type A aortic dissection

Cristina Morante-Pereaa  *  , bibliographic search, manuscript drafting; Tomás Cantón-Rubioa  , bibliographic search, manuscript drafting; Luis Manuel Hernando-Romeroa  , rewiew process and final approval of the manuscript; José Alfonso Buendía-Miñanob  , bibliographic search, manuscript drafting; José Moreu-Burgosa  , rewiew process and final approval of the manuscript; Luis Rodríguez-Padiala  , rewiew process and final approval of the manuscript

aServicio de Cardiología, Hospital Universitario de Toledo, Toledo, Spain

bServicio de Cirugía Cardiaca, Hospital Universitario de Toledo, Toledo, Spain

To the Editor,

Coronary malperfusion in patients with aortic dissection further worsens prognosis due to compromised myocardial blood flow. The incidence rate of coronary disease goes from 9% to 10% according to various registries.1,2 Also, it can occur simultaneously at the beginning of dissection, during the patient transfer or in the middle of surgery. The management of these patients is still a matter of discussion. The optimal time of myocardial reperfusion is 90 min, a timeframe that cannot be guaranteed with surgical revascularization associated with aortic valve repair surgery.

This is the case of a 65-year-old man. The patient was a smoker with chronic kidney disease who was admitted to our center as a «myocardial infarction code» case due to suspected anterior ST-segment elevation acute coronary syndrome. The coronary angiography revealed the presence of a type A aortic dissection with coronary malperfusion due to left main coronary artery (LMCA) occlusion.

The patient had reported to his tertiary referral center with a 30-min history of oppressive retrosternal chest pain. Upon arrival at the emergency room, he remained symptomatic and hemodynamically unstable (pale, sweaty, low arterial blood pressure levels, 60/40 mmHg). The electrocardiogram showed anterior ST-segment elevation and aVR changes, which is why the «myocardial infarction code» was activated and the patient transferred to our center. The cardiac ultrasound revealed the presence of a severely depressed left ventricular ejection fraction (visual estimate of 10% to 15%) with changes in segmental contractility located in the anterior, septal, and lateral walls without pericardial effusion. A total of 300 mg of acetylsalicylic acid, 180 mg of ticagrelor, and vasoactive drugs were administered to the patient.

The patient was sent to the cath lab right away. Given the situation of established cardiogenic shock (stage D) and the potential need for percutaneous circulatory support systems (intra-aortic balloon pump, Impella, Abiomed, United States), the femoral access route was selected (bilateral common femoral artery puncture with 6-Fr introducers).

Initial complications were found in the selective catheterization of the left coronary artery via right femoral access and direct guide catheter insertion (due to highly suspected LMCA disease). Due to suspected type A aortic dissection, an aortogram was performed using a pigtail catheter that confirmed this suspicion and LMCA disease due to hematoma/intimal flap with subtotal occlusion (videos 1 and 2 of the supplementary data).

The criterion for remaining in the true lumen was the presence of an aortic pressure curve of normal morphological characteristics (non-damped) using a 0.35 in 260 cm Teflon-coated guidewire for catheter exchange.

Simultaneously, the cardiac surgery unit was contacted and it was decided to proceed with an emergency percutaneous revascularization as a bridging therapy until definitive surgical treatment. A 6-Fr JL4 guide catheter (Mach 1, Boston Scientific, United States) was used to facilitate the subselective catheterization of the LMCA and perform maneuvers to increase active support (deep intubations) if necessary (sacrificing greater passive support but with better maneuverability compared to other catheters). Once the stay inside the true lumen was confirmed, a 0.014 in angioplasty guidewire was advanced towards the distal third of the left anterior descending coronary artery. A hydrophilic, intermediate weight guidewire was used (SION black, Asahi, Japan).

Afterwards, a 3.5 mm x 16 mm drug-eluting stent was implanted with 50% protrusion of the device into the ascending aorta to simulate the «chimney stent» technique used in cases of damaged coronary ostia during transcatheter aortic valve implantations. The stent was deployed at low (nominal) pressure to minimize the risk of dissection of the LMCA uncovered by the stent and, at least initially, free from significant atherosclerotic disease.

This stabilized the patient's hemodynamic status significantly. The echocardiography confirmed the improvement of left ventricular systolic function.

An emergency computed tomography scan of the aorta revealed the presence of a Standford type A aortic dissection without damage to supra-aortic trunks or the rest of the aorta. Surgery was planned based on the patient's hemodynamic instability, high risk of bleeding, and baseline anatomy (dilated aortic root and ascending aorta). The goal was to use a surgical technique that would require the shortest possible time on extracorporeal circulation. Based on the previous considerations, the Bentall-Bono technique was used. Both the aortic root and the ascending aorta were replaced for a no. 25 Carboseal valved conduit (Palex Medical, Spain) followed by coronary ostia re-implantation. Intraoperatively, the roof of the left main coronary artery was ruptured and the stent malapposed to the arterial walls, which led to the removal and further reinforcement of both the roof of the LMCA and left coronary ostium with 6/0 sutures, and a pericardial patch, respectively. The total time on extracorporeal circulation was 12 min.

The patient did fine after the surgery, was successfully extubated, and eventually discharged from the hospital. Prior to being discharge, an echocardiogram confirmed the presence of preserved systolic function (left ventricular ejection fraction of 55%) with mild hypokinesis of the anterior septum and proper positioning and functioning of the valved conduit.

In conclusion, this patient was initially treated of an anterior ST-segment elevation acute coronary syndrome (KK-IV). During coronary angiography, however, he was diagnosed with a type A aortic dissection that led to coronary malperfusion due to the protrusion of the dissection flap into the left main coronary artery. An urgent decision was made for drug-eluting stent implantation into the LMCA, which improved perfusion to the left coronary tree and provided enough hemodynamic stabilization to proceed with cardiac surgery.

In a series by Uchida et al.1 of 25 patients with type A aortic dissection and signs and symptoms of coronary malperfusion, 11 underwent preoperative coronary angiography while 9 went to surgery right away. In those treated with coronary angiography, if coronary flow was compromised following dissection, a drug-eluting stent was implanted. If ventricular function improved, emergency surgery was performed. Otherwise, veno-arterial extracorporeal membrane oxygenation cannulation was used after surgery. Patients who underwent coronary angiography had a better prognosis.

REFERENCES

1. Uchida K, Karube N, Minami T, et al. Treatment of coronary malperfusion in type A acute aortic dissection. Gen Thorac Cardiovas Surg. 2018;66:621-625. [ Links ]

2. Czerny M, Schoenhoff F, Etz C, et al. The impact of pre-operative malperfusion on outcome in acute type A aortic dissection. Results from the GERAADA registry. J Am Coll Cardiol. 2015;65:2628-2635. [ Links ]

SUPPLEMENTARY DATA

https://doi.org/10.24875/RECIC.M23000392

Supplementary data associated with this article can be found in the online version available at https://doi.org/10.24875/RECIC.M23000392.

FUNDINGNone whatsoever.

*Corresponding author. E-mail address: Cristinamorante94@gmail.com (C. Morante Perea). ✗ @MorantePerea

CONFLICTS OF INTEREST

None reported.

AUTHORS’ CONTRIBUTIONS

C. Morante Perea, T. Cantón Rubio, and J.A. Buendía Miñano were all involved in the patient healthcare process, bibliographic search, and manuscript drafting. L.M. Hernando Romero, J. Moreu Burgos, and L. Rodríguez Padial participated in the rewiew process and final approval of the manuscript.

Creative Commons License Sociedad Española de Cardiología. Publicado por Permanyer Publications. Este es un artículo open access bajo la licencia CC BY-NC-ND 4.0