<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0003-3170</journal-id>
<journal-title><![CDATA[Angiología]]></journal-title>
<abbrev-journal-title><![CDATA[Angiología]]></abbrev-journal-title>
<issn>0003-3170</issn>
<publisher>
<publisher-name><![CDATA[Arán Ediciones S.L.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0003-31702020000700007</article-id>
<article-id pub-id-type="doi">10.20960/angiologia.00194</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Aneurisma del arco aórtico. Tratamiento con stent multicapa diversor de flujo más embolización con coils]]></article-title>
<article-title xml:lang="en"><![CDATA[Aortic arch aneurysm. Treatment with multilayer flow modulator plus coil embolization]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González Duarte]]></surname>
<given-names><![CDATA[Santiago]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López Ney]]></surname>
<given-names><![CDATA[Carlos]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Griego]]></surname>
<given-names><![CDATA[Viviana]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[Fernando de]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Percovich]]></surname>
<given-names><![CDATA[Alejandro Esperón]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Hospital de Clínicas Centro Cardiovascular Universitario Cátedra de Cirugía Vascular Periférica]]></institution>
<addr-line><![CDATA[Montevideo ]]></addr-line>
<country>Uruguay</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2020</year>
</pub-date>
<volume>72</volume>
<numero>6</numero>
<fpage>319</fpage>
<lpage>322</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S0003-31702020000700007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S0003-31702020000700007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S0003-31702020000700007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen Para el tratamiento de la patología del arco aórtico, la cirugía abierta continúa siendo el gold standard. Debido a sus altas morbilidad y mortalidad se han desarrollado diferentes técnicas alternativas. Entre estas, destacan los tratamientos híbridos y exclusivamente endovasculares. En el marco de la investigación, se ha utilizado un stent multicapa diversor de flujo. Presentamos nuestra experiencia en un caso en el que implantamos un stent multicapa diversor de flujo en un paciente con aneurisma del arco aórtico. En la evolución requirió técnica de coiling del aneurisma trans-stent con éxito técnico. No logramos evaluar el éxito clínico en un plazo suficiente debido a muerte precoz por una causa no relacionada.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Currently open surgery continues to be the gold standard for the treatment of aortic arch pathology. Due to its high morbidity and mortality, different alternative techniques such as hybrid or endovascular treatment have been developed. In the framework of these investigations, the multilayer flow modulator stent has been used with technical success. We present our early experience in a male patient with an aortic arch aneurysm, using an MFM and also a trans stent coiling technique. Despite technical success, long-term outcomes could not be assessed due to premature death from unrelated causes.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Aneurisma del arco aórtico]]></kwd>
<kwd lng="es"><![CDATA[Stent multicapa modulador de flujo]]></kwd>
<kwd lng="es"><![CDATA[Embolización con coils]]></kwd>
<kwd lng="en"><![CDATA[Aortic arch aneurysm]]></kwd>
<kwd lng="en"><![CDATA[Multilayer flow modulator stent]]></kwd>
<kwd lng="en"><![CDATA[Coils embolization]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Czerny]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Schmidi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Adler]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Editor's Choice-Current Options and Recommendations for the Treatment of Thoracic Aortic Pathologies Involving the Aortic Arch:An Expert Consensus Document of the European Association for Cardio-Thoracic Surgery (EACTS) &amp;the European Society for Vascular Surgery (ESVS)]]></article-title>
<source><![CDATA[EJEVS]]></source>
<year>2019</year>
<volume>57</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>165-98</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Russo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Icasuriaga]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Tratamiento híbrido de aneurisma del arco aórtico]]></article-title>
<source><![CDATA[Angio]]></source>
<year>2017</year>
<volume>69</volume>
<page-range>370-2</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pinto]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Garas]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Harling]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Is endovascular treatment with multilayer flow modulator stent insertion a safe alternative to open surgery for high-risk patients with thoracoabdominal aortic aneurysm?]]></article-title>
<source><![CDATA[Ann Med Surg]]></source>
<year>2017</year>
<volume>15</volume>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sultan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hynes]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Kavanagh]]></surname>
<given-names><![CDATA[EP]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[How does the multilayer flow modulator work? The science behind the technical innovation]]></article-title>
<source><![CDATA[J Endovasc Ther]]></source>
<year>2014</year>
<volume>21</volume>
<page-range>814-21</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sultan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sultan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hynes]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Early mid-term results of the first 103 cases of multilayer flow modulator stent done under indication for use in the management of thoracoabdominal aortic pathology from the independent global MFM registry]]></article-title>
<source><![CDATA[J Cardiovasc Surg.]]></source>
<year>2014</year>
<volume>55</volume>
<page-range>21-32</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oderich]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evidence of use of multilayer flow modulator stents in treatment of thoracoabdominal aortic aneurysms and dissections]]></article-title>
<source><![CDATA[J Vasc Surg]]></source>
<year>2017</year>
<volume>65</volume>
<page-range>935-7</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nathan]]></surname>
<given-names><![CDATA[DP]]></given-names>
</name>
<name>
<surname><![CDATA[Boonn]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Lai]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Presentation, complications, and natural history of penetrating atherosclerotic ulcer disease]]></article-title>
<source><![CDATA[J Vasc Surg]]></source>
<year>2012</year>
<volume>55</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>10-5</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henkin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Negrotto]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Pollak]]></surname>
<given-names><![CDATA[PM]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Platypnea-Orthodeoxia Syndrome:Diagnostic Challenge and the Importance of Heightened Clinical Suspicion]]></article-title>
<source><![CDATA[Tex Heart Inst J]]></source>
<year>2015</year>
<volume>42</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>498-501</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De La Rosa]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pazos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Síndrome platina ortodoxia, por foramen oval permeable luego de implante de stent en aorta torácica]]></article-title>
<source><![CDATA[Rev Urug Cardiol]]></source>
<year>2017</year>
<volume>32</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>64</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kolvenbach]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Contemporary strategies for repair of complex thoracoabdominal aortic aneurysms:real-world experiences and multilayer stents as an alternative]]></article-title>
<source><![CDATA[J Vasc Bras]]></source>
<year>2017</year>
<volume>16</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>293-303</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
