<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0365-6691</journal-id>
<journal-title><![CDATA[Archivos de la Sociedad Española de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Arch Soc Esp Oftalmol]]></abbrev-journal-title>
<issn>0365-6691</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Española de Oftalmología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0365-66912005000400008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Lentes intraoculares con filtros para luz azul]]></article-title>
<article-title xml:lang="en"><![CDATA[Intraocular lenses with blue light filter]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cristóbal]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sierra]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martín]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ascaso]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital Clínico Universitario Lozano Blesa  ]]></institution>
<addr-line><![CDATA[Zaragoza ]]></addr-line>
<country>España</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2005</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2005</year>
</pub-date>
<volume>80</volume>
<numero>4</numero>
<fpage>245</fpage>
<lpage>249</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S0365-66912005000400008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S0365-66912005000400008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S0365-66912005000400008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Objetivo: Comparar si la lente intraocular SN60AT «Natural»® (Alcon), con filtro IMPRUV® (Alcon), aporta mejorías en la visión de los pacientes intervenidos de catarata con respecto a la Acrysof SA60® (Alcon). Métodos: Estudio prospectivo analítico, sobre treinta y dos pacientes (64 ojos) que presentaban catarata. Se realizó facoemulsificación con implante, tras un método de asignación aleatorio, de una lente Acrysof SN60AT (Natural) en un ojo y en el ojo contralateral de una Acrysof SA60. Determinamos diferencias entre ambas lentes para las variables de sensibilidad al contraste (CSV 1000E®. Vistech), percepción de los colores (Farnsworth 25) y una valoración subjetiva por el paciente a través de una encuesta. Se realizó un estudio estadístico para comparación de ambas muestras. Resultados: Los resultados de sensibilidad al contraste se obtuvieron para las frecuencias de 3, 6, 12 y 18 ciclos por grado (cpd) en condiciones escotópicas obteniendo una diferencia a favor de SN60AT de 0,75 (unidades de test del CSV 1000E) para 3 cpd, 0,86 para 6 cpd, 0,54 para 12 cpd y 0,35 para 18 cpd, siendo estadísticamente significativa esta diferencia en el caso de las dos primeras. Un 62,5% de pacientes con lente tintada y un 50% de los pacientes con SA60 realizaron el test de Farnsworth 25 con buen resultado, un 12,5% y un 21% regular, y un 25% y un 28,1% mal. Conclusiones: Hemos obtenido una mejora para todas las frecuencias a favor de la lente tintada, siendo estadísticamente significativas para las frecuencias bajas (3 y 6 cpd.) No hemos apreciado diferencias significativas en la realización del test de Farnsworth, ni el paciente las refiere a través del test subjetivo. La tinción que supone la adición del filtro IMPRUV® (Alcon), conlleva un aumento en la sensibilidad al contraste sin consecuencias para la percepción de los colores.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Purpose: To evaluate if a SN60AT «Natural»® IOL (Alcon) with IMPRUV filter ®(Alcon) offers any advantage in patients having cataract surgery, as compared with Acrysof SA60® IOL (Alcon). Methods: This was a prospective analytical study. We studied sixty-four eyes from 32 patients with cataracts. After a random assignment, phacoemulsification with the implant was performed using the Acrysof SN60AT tinted lens in one eye and Acrysof SA60 in the other. A variety of variables was subsequently assessed: contrast sensitivity with a CSV 1000E test, colour perception through a Farnsworth 25 test and subjective measures by a patient survey. Differences between the groups were assessed statistically. Results: The contrast sensitivity results were obtained for 3, 6, 12 and 18 cycles per degree (cpd) frequencies under scotopic conditions, with better results obtained following the use of SN60AT: 0.75 (CSV 1000E test units) for 3 cpd, 0.86 for 6 cpd, 0.54 for 12 cpd and 0.35 for 18 cpd. The differences were statistically significant between the two groups for 3 cpd and 6 cpd. A total of 62.5% of patients using a tinted lens and 50% with SA60 achieved good results in the Farnsworth test; 12.5% and 21% had fair results and 25% and 28.1% respectively had poor results. Conclusions: We obtained an improvement in favour of the tinted lens for all frequencies, with this being statistically significant at lower frequencies (3 and 6 cpd). No significant differences in the Farnsworth test performance or in the patient survey were found. The tinting provided by the IMPRUV filter brings an increase in contrast sensitivity without affecting colour perception.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Lentes intraoculares]]></kwd>
<kwd lng="es"><![CDATA[filtros]]></kwd>
<kwd lng="es"><![CDATA[luz azul]]></kwd>
<kwd lng="es"><![CDATA[sensibilidad al contraste]]></kwd>
<kwd lng="es"><![CDATA[cataratas]]></kwd>
<kwd lng="en"><![CDATA[Intraocular lens]]></kwd>
<kwd lng="en"><![CDATA[filters]]></kwd>
<kwd lng="en"><![CDATA[blue light]]></kwd>
<kwd lng="en"><![CDATA[contrast sensitivity]]></kwd>
<kwd lng="en"><![CDATA[cataracts]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><b>ARTÍCULO        ORIGINAL</b></p>       <hr align="left">           <p align="center"><b><font size="4">&nbsp;LENTES INTRAOCULARES CON FILTROS PARA LUZ AZUL&nbsp;</font></b>       </p>           <p align="center"><B>       INTRAOCULAR LENSES WITH BLUE LIGHT FILTER</B>       </p>     <P align=center>CRISTÓBAL JA<sup>1</sup>, SIERRA J<sup>2</sup>, MARTÍN J<sup>2</sup>, RODRÍGUEZ NA<sup>2</sup>, ASCASO J<sup>1</sup></P>     <P align=center>&nbsp;</P>       <table width="100%">         <tr>           <td width="48%" valign="top">     <P align=center><B>   RESUMEN</P></B>     <p><B>Objetivo:</B> Comparar si la lente intraocular  SN60AT «Natural»<SUP>®</SUP> (Alcon), con filtro IMPRUV<SUP>®</SUP> (Alcon),  aporta mejorías en la visión de los pacientes intervenidos de catarata con  respecto a la Acrysof SA60<SUP>® </SUP>(Alcon).<B>    <br> Métodos:</B> Estudio prospectivo  analítico, sobre treinta y dos pacientes (64 ojos) que presentaban catarata. Se  realizó facoemulsificación con implante, tras un método de asignación aleatorio,  de una lente Acrysof SN60AT (Natural) en un ojo y en el ojo contralateral de una  Acrysof SA60. Determinamos diferencias entre ambas lentes para las variables de  sensibilidad al contraste (CSV 1000E<SUP>®</SUP>. Vistech), percepción de los  colores (Farnsworth 25) y una valoración subjetiva por el paciente a través de  una encuesta.    <br> Se realizó un estudio estadístico para comparación de  ambas muestras.<B>    <br> Resultados:</B> Los resultados de  sensibilidad al contraste se obtuvieron para las frecuencias de 3, 6, 12 y 18  ciclos por grado (cpd) en condiciones escotópicas obteniendo una diferencia a  favor de SN60AT de 0,75 (unidades de test del CSV 1000E) para 3 cpd, 0,86 para 6  cpd, 0,54 para 12 cpd y 0,35 para 18 cpd, siendo estadísticamente significativa  esta diferencia en el caso de las dos primeras.    ]]></body>
<body><![CDATA[<br> Un 62,5% de pacientes con lente tintada y un 50% de  los pacientes con SA60 realizaron el test de Farnsworth 25 con buen resultado,  un 12,5% y un 21% regular, y un 25% y un 28,1% mal.<B>    <br> Conclusiones:</B> Hemos obtenido  una mejora para todas las frecuencias a favor de la lente tintada, siendo  estadísticamente significativas para las frecuencias bajas (3 y 6 cpd.)    <br> No hemos apreciado diferencias significativas en la  realización del test de Farnsworth, ni el paciente las refiere a través del test  subjetivo.    <br> La tinción que supone la adición del filtro  IMPRUV<SUP>®</SUP> (Alcon), conlleva un aumento en la sensibilidad al contraste  sin consecuencias para la percepción de los colores.</P><B>     <p>Palabras clave:</B> Lentes  intraoculares, filtros, luz azul, sensibilidad al contraste,  cataratas.</P>           </td>           <td width="4%" valign="top">&nbsp;</td>           <td width="48%" valign="top">     <p align="center"><B> SUMMARY</P></B>     <p><B>Purpose:</B> To evaluate if a SN60AT  «Natural»<SUP>® </SUP>IOL (Alcon) with IMPRUV filter <SUP>®</SUP>(Alcon) offers  any advantage in patients having cataract surgery, as compared with Acrysof  SA60<SUP>®</SUP> IOL (Alcon).<B>    <br> Methods:</B> This was a  prospective analytical study. We studied sixty-four eyes from 32 patients with  cataracts. After a random assignment, phacoemulsification with the implant was  performed using the Acrysof SN60AT tinted lens in one eye and Acrysof SA60 in  the other. A variety of variables was subsequently assessed: contrast  sensitivity with a CSV 1000E test, colour perception through a Farnsworth 25  test and subjective measures by a patient survey. Differences between the groups  were assessed statistically.<B>    <br> Results:</B> The contrast  sensitivity results were obtained for 3, 6, 12 and 18 cycles per degree (cpd)  frequencies under scotopic conditions, with better results obtained following  the use of SN60AT: 0.75 (CSV 1000E test units) for 3 cpd, 0.86 for 6 cpd, 0.54  for 12 cpd and 0.35 for 18 cpd. The differences were statistically significant  between the two groups for 3 cpd and 6 cpd.    <br> A total of 62.5% of patients using a tinted lens and  50% with SA60 achieved good results in the Farnsworth test; 12.5% and 21% had  fair results and 25% and 28.1% respectively had poor results.<B>    ]]></body>
<body><![CDATA[<br> Conclusions:</B> We obtained an  improvement in favour of the tinted lens for all frequencies, with this being  statistically significant at lower frequencies (3 and 6 cpd).    <br> No significant differences in the Farnsworth test  performance or in the patient survey were found. The tinting provided by the  IMPRUV filter brings an increase in contrast sensitivity without affecting  colour perception <I>(Arch Soc Esp Oftalmol 2005; 80:  245-250).</P></I><B>     <p>Key words:</B> Intraocular lens,  filters, blue light, contrast sensitivity, cataracts.</P></td>         </tr>       </table>     <p>&nbsp;</P><hr align="left" width="30%">     <p><font size="2">Recibido: 21/7/04. Aceptado: 12/4/05.    <br> Hospital Clínico Universitario Lozano Blesa. Zaragoza. España.    <br> <sup>1</sup> Doctor en Medicina.    <br> <sup>2</sup> Licenciado en Medicina.    <br> Los autores manifiestan no tener ningún interés comercial ni haber recibido apoyo económico.    <br>     ]]></body>
<body><![CDATA[<br> Correspondencia:    <br> J. Sierra    <br> HCUZ Lozano Blesa    <br> San Juan Bosco, 15    <br> 50009 Zaragoza    <br> España</font></P><B>       <P align=center>INTRODUCCIÓN</P></B>     <p>La lente intraocular SN60AT <I>«Natural»</I> (Alcon)  incorpora, además de un filtro ultravioleta como otras lentes del mercado, una  tinción amarilla basada en la unión covalente de un cromóforo al material  acrílico. Este cromóforo filtra la luz azul (filtra el espectro lumínico desde  400 a 550 nm aproximadamente), responsable de la creación de radicales libres al  actuar sobre la lipofuscina acumulada por el envejecimiento del epitelio  pigmentario retiniano (EPR) (1-5). Los radicales libres están involucrados en el  proceso de envejecimiento y existen evidencias de su relación con el daño  inicial que desencadena la degeneración macular asociada a la edad (DMAE)  (6-12).</P>     <p>Este filtro es de una coloración amarillenta de  similares características al que adquiere con el envejecimiento normal el  cristalino humano (13).</P>     <p>La tinción amarilla de la lente intraocular, puede  inducir un aumento de sensibilidad al contraste por analogía con el uso de  cristales tintados en gafas de sol en situaciones de poco contraste  (14,15).</P>     ]]></body>
<body><![CDATA[<p>El estudio pretende demostrar si existen diferencias  en la sensibilidad al contraste (16-18), alteraciones en la percepción de los  colores y cuál es la sensación de confort que el paciente obtiene al utilizar la  lente <I>Natural.</I>&nbsp;&nbsp;</P><B>     <P align=center>MATERIAL Y MÉTODOS</P></B>     <p>Estudio prospectivo analítico, de una población de  pacientes susceptibles de ser intervenidos de catarata con implante de lente  intraocular intrasacular.</P>     <p>Se estudia una muestra de 64 ojos (32 pacientes con  catarata bilateral).</P>     <p>Se han implantado 64 lentes intraoculares sin  complicaciones intra- o postoperatorias.</P>     <p>La edad media de los pacientes incluidos en la  muestra fue de 75,5 años (DE: 6,02) (lógicamente la misma para ambos grupos). El  43,75% hombres y el 56,25% mujeres.</P>     <p>Se han estudiado las siguientes variables:</P>     <blockquote>     <p>1) Puntuaciones obtenidas en el test de sensibilidad  al contraste con el test CSV 1000E (<SUP>®</SUP>Vistech) para 3, 6, 12 y 18  ciclos por grado a la distancia establecida de 2,6 m en condiciones escotópicas  sin deslumbramiento.</P>     <p>2) Errores cometidos en la realización del test de  Farnsworth (25 colores). El investigador anotó la «destreza» con la que el  paciente realizaba la prueba.</P>     ]]></body>
<body><![CDATA[<p>3) Respuestas mejor/peor en la siguiente encuesta de  valoración subjetiva por parte del paciente.</P> </blockquote>     <p>Observe el entorno que le rodea (misma consulta)  primero tapando el ojo izquierdo y después el ojo derecho y responda a las  siguientes cuestiones.</P>     <blockquote>     <p>A) ¿Ve mejor con un ojo que con otro? ¿Con  cuál?</P>     <p>B) ¿Percibe los colores de distinta tonalidad con un  ojo que con otro?</P>     <p>C) ¿Nota mayor deslumbramiento con un ojo que con  otro? ¿Con cuál?</P> </blockquote>     <p>En cuanto a los criterios de exclusión, se excluyeron  del estudio aquellos pacientes que no siguieron las revisiones y tratamientos  propuestos (ninguno), así como los que padecían enfermedades sistémicas con  posible influencia sobre la función visual, defectos refractivos postquirúrgicos  superiores a ± 3 D (dioptrías), complicaciones per- y postquirúrgicas.</P>     <p>Los pacientes firmaron el consentimiento informado y  la normativa ética fue respetada en todo el desarrollo del estudio.</P>     <p>Todos los pacientes fueron intervenidos por el mismo  cirujano.</P>     <p>La elección del tipo de lente a implantar fue  aleatoria antes de intervenir el primer ojo.</P>     ]]></body>
<body><![CDATA[<p>En la técnica quirúrgica empleada todos los pacientes  fueron operados bajo anestesia tópica a través de una incisión córneo-corneal de  2,75 mm, con técnicas de faco-chop y limpieza de masas mecanizada. El implante  de LIO intrasacular fue con inyector Monarch II (Alcon<SUP>®</SUP>).</P>     <p>Tratamiento antibiótico y corticoide tópico durante  cuatro semanas en pauta descendente (Tobramicina + Dexametasona) (Tobradex Susp.  oft., Alcon Cusí, Barcelona).</P>       <B>     <p>Caraterísticas de las LIOs</P></B>           <p>- Ambas son lentes monobloque con un diámetro de    óptica de 6 mm, un tamaño total de 13 mm y asas en C modificada. Óptica    biconvexa, 118,4 de constante y compuestas de material acrílico hidrofóbico.    <br>   - La única diferencia apreciable es que AcrySof SA60    es transparente y AcrySof NA60 incorpora un filtro IMPRUV que le da una    tinción amarilla impidiendo el paso de la luz azul (<a href="#f1">fig. 1</a>). </P>        <P align=center>  <a name="f1">  <IMG height=334  src="/img/aseo/v80n4/f08-01.jpg" width=250 border=0  <FONT color=#000080 size=1></a>    <BR><i><B><font size="2">Fig.  1.</font></B><font size="2"> Lente Acrysof Natural.</font></i></P>     <p>Al mes aproximadamente de la primera cirugía se  intervino el ojo contralateral con implante del otro tipo de LIO.</P>     <p>Se realizaron revisiones al día siguiente de la  intervención, a la semana y al mes de la cirugía controlando agudeza visual  (AV), presión intraocular (PIO) y estudio biomicroscópico.</P>     <p>A las ocho semanas de la cirugía sobre el segundo ojo  se determinaron las variables del estudio (todas las mediciones se realizaron  con la mejor corrección, evaluando cada ojo de forma aislada).</P>     ]]></body>
<body><![CDATA[<p>Los resultados fueron analizados del siguiente  modo:</P>           <p>- Comparación de medias de sensibilidad al contraste    para cada frecuencia: t-Student para datos no apareados con el paquete    estadístico Statview 5.0. (StatView for Windows; SAS Institute Inc.    Copyright<SUP>©</SUP> 1992-1998). </P>          <p>- El test Farnsworth se evaluó como una comparación    porcentual. </P>          <p>- Descripción estadística de las respuestas obtenidas    en el test subjetivo. </P>     <p>Todas las determinaciones fueron realizadas por el  mismo investigador que tras realizar las pruebas observaba en la lámpara de  hendidura el color de LIO implantada anotándolo en la ficha del  paciente.&nbsp;&nbsp;</P>       <B>     <P align=center>RESULTADOS</P></B>     <p>Ambas muestras presentan una gran homogeneidad puesto  que están formadas por los mismos pacientes.</P>     <p>La AV media para visión lejana obtenida (con  corrección cuando se requirió) fue 0,9 (DE: 0,14) para el total de ojos; para  SN60AT 0,92 (DE: 0,15) y para SA60 0,88 (DE: 0,18) (datos obtenidos con los  optotipos de uso habitual en escala decimal).</P>     <p>Los resultados para las distintas frecuencias de  sensibilidad al contraste a los dos meses de la cirugía en el segundo ojo fueron  los siguientes (<a href="#f2">fig. 2</a> y <a href="#t1"> tabla I</a>).</P>     <P align=center>  <a name="f2">  <IMG height=310  src="/img/aseo/v80n4/f08-02.gif" width=469 border=0  <FONT color=#000080 size=1></a>    ]]></body>
<body><![CDATA[<BR><i><B><font size="2">Fig.  2.</font></B><font size="2"> Medias de sensibilidad al contraste obtenidas&nbsp;    <br>  (ordenadas: unidades de  sensibilidad al contraste; abscisas: frecuencias).</font></i></P>     <P align=center><a name="t1"><IMG height=192 src="/img/aseo/v80n4/t08-01.gif" width=461  border=0></a></P>     <p>Para 3 cpd la media para la SA60 2,4 y para SN60AT  3,15, para 6 cpd fueron 1,6 y 2,46 respectivamente. La diferencia obtenida fue  estadísticamente significativa en ambas con una diferencia de casi una unidad de  sensibilidad al contraste en el test CSV.</P>     <p>Para 12 cpd las medias fueron 1 para la SA60 y 1,54  para la SN60AT y de modo similar ocurrió para 18 cpd con unos valores de 0,8 y  1,15 ambas no estadísticamente significativas.</P>     <p>Se valoró el test de Farnsworth 25 en función de los  errores cometidos en el ordenamiento de los colores: bueno <font size="2"> &#8804;</font> 2 fallos;  regular= 3-5 fallos y malo <font size="2"> &#8805;</font> 6 fallos.</P>     <p>En la SN60AT los resultados fueron 62,5% bueno, 12,5%  regular y 25% malo</P>     <p>Para SA60 fueron 50% bueno, 21,9 regular y 28,1  malo.</P>     <p>Los resultados del test subjetivo fueron:</P>         <blockquote>           ]]></body>
<body><![CDATA[<p>- Ningún paciente refirió percibir los colores de    distinta tonalidad con uno u otro ojo. </P>          <p>- Tres pacientes notaban mayor deslumbramiento con    uno de sus ojos (2 con la SA60 y 1 con la SN60AT). </P>          <p>- Seis pacientes (18,8%) dijeron ver peor con uno de    sus ojos coincidiendo en todos los casos con el ojo que requería mayor    corrección, sin estar asociado con una clara preferencia por una de las LIOs. &nbsp;&nbsp;</P> </blockquote>       <B>     <P align=center>DISCUSIÓN</P></B>     <p>La adición de un filtro para la luz azul en las  lentes intraoculares supone una mejora en los test de sensibilidad al contraste  para las distintas frecuencias en condiciones escotópicas, sin conllevar una  deformación de la percepción de los colores por parte del paciente.</P>     <p>Esta mejoría no llega a ser de un punto por fila en  la escala de medición del test de sensibilidad al contraste, pero sí supone un  aumento con respecto a la lente AcrySof monobloque transparente.</P>     <p>De confirmarse estos resultados a más largo plazo, la  aplicación de filtros con potenciales efectos protectores retinianos, debería  imponerse a las actuales lentes que solo incluyen filtros para la luz UV  buscando una prótesis lo más similar en características ópticas y visuales al  cristalino humano adulto.</P>     <p>El conocer que estas lentes pueden ser utilizadas sin  una disminución en la calidad de la visión obtenida por el paciente nos  permitirá con su uso, realizar los estudios epidemiológicos necesarios para  comprobar su efectividad in vivo como factor protector en el desarrollo de  degeneración macular adquirida con la edad.</P>     <p>La lente aporta la ventaja de una potencial  protección sobre la producción de radicales libres a nivel del EPR y en  consecuencia una prevención de la aparición de DMAE.</P>     <p>Además, el paciente no percibe que es portador de una  lente no transparente.</P>     ]]></body>
<body><![CDATA[<p>Queda demostrada una mejoría de la sensibilidad al  contraste, sin influencia sobre la percepción del color con el uso de la LIO  Natural.</P>     <p>&nbsp;&nbsp;</P><B>     <P align=center>BIBLIOGRAFÍA</P></B>           <!-- ref --><p>1. Sparrow JR, Nakanishi K, Parish CA. The lipofuscin fluorophore    A2E mediates blue light-induced damage to retinal pigmented epithelial cells.    Invest Ophthalmol Vis Sci 2000; 41: 1981-1989. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860582&pid=S0365-6691200500040000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Sparrow JR, Parish CA, Hashimoto M, Nakanishi K. A2E, a    lipofuscin fluorophore, in human retinal pigmented epithelial cells in    culture. Invest Ophthalmol Vis Sci 1999; 40: 2988-2995. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860583&pid=S0365-6691200500040000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Sparrow JR, Cai B. Blue light-induced apoptosis of    A2E-containing RPE: involvement of caspase-3 and protection by Bcl-2. Invest    Ophthalmol Vis Sci 2001; 42: 1356-1362. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860584&pid=S0365-6691200500040000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Sparrow JR, Zhou J, Ben-Shabat, Vollmer H, Itagaki Y, Nakanishi    K. Involvement of oxidative mechanisms in blue-light-induced damage to    A2E-Laden RPE. Invest Ophthalmol Vis Sci 2002; 43: 1222-1227. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860585&pid=S0365-6691200500040000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. Wasowicz M, Morice C, Ferrari P, Callebert J, Versaux-Botteri C.    Long-term effects of light damage on the retina of albino and pigmented rats.    Invest Ophthalmol Vis Sci 2002; 43: 813-820. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860586&pid=S0365-6691200500040000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. Feeney-Burns L, Hilderbrand ES, Eldridge S. Aging human RPE:    morphometric analysis of macular, equatorial, and peripheral cells. Invest    Ophthalmol Vis Sci 1984; 25: 195-200. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860587&pid=S0365-6691200500040000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. Cai J, Wu M, Nelson KC, Sternberg P Jr, Jones DP.    Oxidant-induced apoptosis in cultured human retinal pigment epithelial cells.    Invest Ophthalmol Vis Sci 1999; 40: 959-966. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860588&pid=S0365-6691200500040000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Organisciak DT, Kutty RK, Leffak M, Wong P, Messing S, Wiggert    B, et al. Oxidative damage and responses in retinal nuclei arising from    intense light exposure. In Anderson RE. Degenerative Disease of the Retina.    New York: Plenum Press; 1995. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860589&pid=S0365-6691200500040000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Pollak A, Marcovich A, Bukelman A, Oliver M. Age-related macular    degeneration after extracapsular cataract extraction with intraocular lens    implantation. Ophthalmology 1996; 103: 1546-1554. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860590&pid=S0365-6691200500040000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Young RW. Solar radiation and age-related macular degeneration.    Surv Ophthalmol 1988; 32: 252-269. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860591&pid=S0365-6691200500040000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11. Winkler BS, Boulton ME, Gottsch JD, Sternberg P. Oxidative    damage and age-related macular degeneration. Mol Vis 1999; 5: 32. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860592&pid=S0365-6691200500040000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Klein R, Klein BE, Wang Q, Moss SE. Is age-related maculopathy    associated with cataracts? Arch Ophthalmol 1994; 112: 191-196. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860593&pid=S0365-6691200500040000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Taylor HR, West S, Munoz B, Rosenthal FS, Bressler SB, Bressler    NM. The long-term effects of visible light on the eye. Arch Ophthalmol 1992;    110: 99-104. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860594&pid=S0365-6691200500040000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Hovis JK, Lovasik JV, Cullen AP, Kothe AC. Physical    characteristics and perceptual effects of «blue-blocking» lenses. Optom Vis    Sci 1989; 66: 682-689. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860595&pid=S0365-6691200500040000800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Niwa K, Yoshino Y, Okuyama F, Tokoro T. Effects of tinted    intraocular lens on contrast sensitivity. Ophthalmic Physiol Opt 1996; 16:    297-302. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860596&pid=S0365-6691200500040000800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Fristrom B, Lundh BL. Colour contrast sensitivity in cataract    and pseudophakia. Acta Ophthalmol Scand 2000; 78: 506-511. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860597&pid=S0365-6691200500040000800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Contrast sensitivity and glare testing in the evaluation of    anterior segment disease. American Academy of Ophthalmology. Ophthalmology    1990; 97: 1233-1237. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860598&pid=S0365-6691200500040000800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Miller D. Contrast sensitivity and glare. In: Tasman W, Jaeger    EA. Duane´s Clinical Ophthalmology. Philadelphia: Lippincott, Williams &amp;    Wilkins; 1996. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=860599&pid=S0365-6691200500040000800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sparrow]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Nakanishi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Parish]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The lipofuscin fluorophore A2E mediates blue light-induced damage to retinal pigmented epithelial cells]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2000</year>
<volume>41</volume>
<page-range>1981-1989</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sparrow]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Parish]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Hashimoto]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Nakanishi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A2E, a lipofuscin fluorophore, in human retinal pigmented epithelial cells in culture]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>1999</year>
<volume>40</volume>
<page-range>2988-2995</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sparrow]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Cai]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Blue light-induced apoptosis of A2E-containing RPE: involvement of caspase-3 and protection by Bcl-2]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2001</year>
<volume>42</volume>
<page-range>1356-1362</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sparrow]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ben-Shabat,]]></surname>
</name>
<name>
<surname><![CDATA[Vollmer]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Itagaki]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Nakanishi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Involvement of oxidative mechanisms in blue-light-induced damage to A2E-Laden RPE]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2002</year>
<volume>43</volume>
<page-range>1222-1227</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wasowicz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Morice]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Callebert]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Versaux-Botteri]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long-term effects of light damage on the retina of albino and pigmented rats]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2002</year>
<volume>43</volume>
<page-range>813-820</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feeney-Burns]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hilderbrand]]></surname>
<given-names><![CDATA[ES]]></given-names>
</name>
<name>
<surname><![CDATA[Eldridge]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aging human RPE: morphometric analysis of macular, equatorial, and peripheral cells]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>1984</year>
<volume>25</volume>
<page-range>195-200</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cai]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Nelson]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
<name>
<surname><![CDATA[Sternberg]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Jones]]></surname>
<given-names><![CDATA[DP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oxidant-induced apoptosis in cultured human retinal pigment epithelial cells]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>1999</year>
<volume>40</volume>
<page-range>959-966</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Organisciak]]></surname>
<given-names><![CDATA[DT]]></given-names>
</name>
<name>
<surname><![CDATA[Kutty]]></surname>
<given-names><![CDATA[RK]]></given-names>
</name>
<name>
<surname><![CDATA[Leffak]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Messing]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wiggert]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oxidative damage and responses in retinal nuclei arising from intense light exposure]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[RE.]]></given-names>
</name>
</person-group>
<source><![CDATA[Degenerative Disease of the Retina]]></source>
<year>1995</year>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Plenum Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pollak]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Marcovich]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bukelman]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Oliver]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Age-related macular degeneration after extracapsular cataract extraction with intraocular lens implantation]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>1996</year>
<volume>103</volume>
<page-range>1546-1554</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Young]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solar radiation and age-related macular degeneration]]></article-title>
<source><![CDATA[Surv Ophthalmol]]></source>
<year>1988</year>
<volume>32</volume>
<page-range>252-269</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Winkler]]></surname>
<given-names><![CDATA[BS]]></given-names>
</name>
<name>
<surname><![CDATA[Boulton]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
<name>
<surname><![CDATA[Gottsch]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
<name>
<surname><![CDATA[Sternberg]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oxidative damage and age-related macular degeneration]]></article-title>
<source><![CDATA[Mol Vis]]></source>
<year>1999</year>
<volume>5</volume>
<page-range>32</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Klein]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Klein]]></surname>
<given-names><![CDATA[BE]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Moss]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Is age-related maculopathy associated with cataracts?]]></article-title>
<source><![CDATA[Arch Ophthalmol]]></source>
<year>1994</year>
<volume>112</volume>
<page-range>191-196</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[HR]]></given-names>
</name>
<name>
<surname><![CDATA[West]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Munoz]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenthal]]></surname>
<given-names><![CDATA[FS]]></given-names>
</name>
<name>
<surname><![CDATA[Bressler]]></surname>
<given-names><![CDATA[SB]]></given-names>
</name>
<name>
<surname><![CDATA[Bressler]]></surname>
<given-names><![CDATA[NM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The long-term effects of visible light on the eye]]></article-title>
<source><![CDATA[Arch Ophthalmol]]></source>
<year>1992</year>
<volume>110</volume>
<page-range>99-104</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hovis]]></surname>
<given-names><![CDATA[JK]]></given-names>
</name>
<name>
<surname><![CDATA[Lovasik]]></surname>
<given-names><![CDATA[JV]]></given-names>
</name>
<name>
<surname><![CDATA[Cullen]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Kothe]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Physical characteristics and perceptual effects of «blue-blocking» lenses]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>1989</year>
<volume>66</volume>
<page-range>682-689</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Niwa]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshino]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Okuyama]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Tokoro]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of tinted intraocular lens on contrast sensitivity]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>1996</year>
<volume>16</volume>
<page-range>297-302</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fristrom]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Lundh]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Colour contrast sensitivity in cataract and pseudophakia]]></article-title>
<source><![CDATA[Acta Ophthalmol Scand]]></source>
<year>2000</year>
<volume>78</volume>
<page-range>506-511</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[Contrast sensitivity and glare testing in the evaluation of anterior segment disease: American Academy of Ophthalmology]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>1990</year>
<volume>97</volume>
<page-range>1233-1237</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Contrast sensitivity and glare]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Tasman]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Jaeger]]></surname>
<given-names><![CDATA[EA.]]></given-names>
</name>
</person-group>
<source><![CDATA[Duane´s Clinical Ophthalmology]]></source>
<year>1996</year>
<publisher-loc><![CDATA[Philadelphia ]]></publisher-loc>
<publisher-name><![CDATA[Lippincott, Williams & Wilkins]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
