<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0365-6691</journal-id>
<journal-title><![CDATA[Archivos de la Sociedad Española de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Arch Soc Esp Oftalmol]]></abbrev-journal-title>
<issn>0365-6691</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Española de Oftalmología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0365-66912006001000004</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Aberraciones ópticas en ojos con lentes de contacto medidas con el sistema de trazado de Rayos]]></article-title>
<article-title xml:lang="en"><![CDATA[Laser Ray Tracing to measure optical aberrations in eyes with contact lenses]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Blázquez-Sánchez]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mendoza-Pérez]]></surname>
<given-names><![CDATA[M.A.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Merayo-LLoves]]></surname>
<given-names><![CDATA[J.M.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
<xref ref-type="aff" rid="A04"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Navarro-Belsué]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Centro de Especialidades Oftalmológicas de Madrid  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Consejo Superior de Investigaciones Científicas. (C.S.I.C.) Instituto de Óptica Danza de Valdés ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Centro de Especialidades Oftalmológicas (CEOS)  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad de Valladolid Instituto de Oftalmobiología Aplicada (IOBA) ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>10</month>
<year>2006</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>10</month>
<year>2006</year>
</pub-date>
<volume>81</volume>
<numero>10</numero>
<fpage>575</fpage>
<lpage>579</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S0365-66912006001000004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S0365-66912006001000004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S0365-66912006001000004&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Objetivo: Evaluar el impacto de las lentes de contacto desechables en la calidad visual, comparando aberraciones ópticas, en ojos miopes, con y sin lentes de contacto. Método: Las aberraciones ópticas se midieron mediante el sistema del Trazado de Rayos Láser, el cuál es un método de medida objetivo, sobre un conjunto de 18 ojos, en 3 condiciones diferentes: a ojo desnudo, ojo más lentes de prueba, ojo con lentes de contacto desechables. Resultados: Existe una alta variabilidad entre sujetos, pero la tendencia general es que las lentes de prueba no modifican las aberraciones, mientras que las lentes de contacto tienden a incrementar las aberraciones oculares para pupilas grandes cerca de un 40% en promedio. Sin embargo tal incremento es mucho menor para pupilas más pequeñas. Conclusión: Este estudio revela que no se produce efectos significativos en la calidad de visión en pacientes que usan lentes de contacto desechables bajo condiciones de luz diurna, así como un pequeño descenso en visión nocturna.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Purpose: To evaluate the impact of disposable soft contact lenses upon visual performance by comparing the optical aberrations of myopic eyes with and without the use of contact lenses. Method: The optical aberrations of a set of 18 eyes were measured by a laser ray tracing system, an objective measurement method, enabling comparison of the findings of the naked eye, the eye plus a test lens, and the eye plus a disposable contact lens. Results: There was a large variability among subjects, but the general tendency was that test lenses did not modify aberrations, whereas contact lenses tended to increase the ocular aberrations for large pupils by an average of 40%. There was a lower increase for smaller pupils. Conclusion: This study predicts there will be no significant adverse effects on the quality of vision from the use of disposable contact lenses worn under daylight conditions, but a small decline in night vision.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Aberraciones]]></kwd>
<kwd lng="es"><![CDATA[lentes de contacto blandas]]></kwd>
<kwd lng="es"><![CDATA[método de trazado de Rayos]]></kwd>
<kwd lng="en"><![CDATA[Aberrations]]></kwd>
<kwd lng="en"><![CDATA[soft contact lenses]]></kwd>
<kwd lng="en"><![CDATA[Laser Ray Tracing]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font face="Verdana" size="2"><b>ARTÍCULO ORIGINAL</b></font></p>      <p align="right">&nbsp;</p>       <p><B><font face="Verdana" size="4"><a name="inicio"></a>Aberraciones ópticas en ojos con lentes de contacto medidas con el sistema de trazado de Rayos</font></p>      <p><font face="Verdana" size="4">Laser Ray Tracing to measure optical aberrations in eyes with contact lenses</font></p>      <p>&nbsp;</p>      <p>&nbsp;</p> </b>     <p><b><font face="Verdana" size="2">Blázquez-Sánchez V.<sup>  1</sup> , Mendoza-Pérez M.A.<sup>  2</sup> , Merayo-LLoves J.M.<sup>  3</sup> , Navarro-Belsué R.<sup>  4</sup> </font></b></p>      <p><font face="Verdana" size="2">Instituto de Óptica &quot;Daza de Valdés&quot;. Consejo  Superior de Investigaciones Científicas(C.S.I.C.). Madrid. España    <br> CEO. &quot;Centro de Especialidades Oftalmológicas&quot;. Madrid</font><font size="2" face="Verdana"><B><i> <sup>      <br> </sup> </i> </B> <sup>  1</sup> Diplomada en Óptica y Optometría. Centro de Especialidades  Oftalmológicas de Madrid    ]]></body>
<body><![CDATA[<br> <sup>  2</sup> Licenciada en Ciencias Físicas. Instituto de Óptica &quot;Danza de  Valdés&quot;. Consejo Superior de Investigaciones Científicas. (C.S.I.C.)    <br> <sup>  3</sup> Doctor en Medicina. CEOS e Instituto de Oftalmobiología Aplicada (IOBA).  Universidad de Valladolid.    <br> <sup>  4</sup> Doctor en Ciencias Físicas. Instituto de Óptica &quot;Danza de Valdés&quot;.  Consejo Superior de Investigaciones Científicas. (C.S.I.C)</font></p>      <p><font face="Verdana" size="2"><a href="#Fin">Dirección para correspondencia</a></font></p>      <p>&nbsp;</p>      <p>&nbsp;</p> <hr size="1">     <p><B>   <font face="Verdana" size="2">RESUMEN</font></p> </B>     <p><font face="Verdana" size="2"><B>Objetivo:</b>Evaluar el impacto de las lentes de  contacto desechables en la calidad visual, comparando aberraciones ópticas, en  ojos miopes, con y sin lentes de contacto.</font><B><font size="2" face="Verdana">    <br> Método</font></B><font size="2" face="Verdana">: Las aberraciones  ópticas se midieron mediante el sistema del Trazado de Rayos Láser, el cuál es  un método de medida objetivo, sobre un conjunto de 18 ojos, en 3 condiciones  diferentes: a ojo desnudo, ojo más lentes de prueba, ojo con lentes de contacto  desechables.</font><B><font size="2" face="Verdana">    <br> Resultados</font></B><font size="2" face="Verdana">: Existe una alta  variabilidad entre sujetos, pero la tendencia general es que las lentes de  prueba no modifican las aberraciones, mientras que las lentes de contacto  tienden a incrementar las aberraciones oculares para pupilas grandes cerca de un  40% en promedio. Sin embargo tal incremento es mucho menor para pupilas más  pequeñas.</font><B><font size="2" face="Verdana">    ]]></body>
<body><![CDATA[<br> Conclusión</font></B><font size="2" face="Verdana">: Este estudio  revela que no se produce efectos significativos en la calidad de visión en  pacientes que usan lentes de contacto desechables bajo condiciones de luz  diurna, así como un pequeño descenso en visión nocturna.</font></p> <B>     <p><font size="2" face="Verdana">Palabras clave:</font></B><font size="2" face="Verdana"> Aberraciones,  lentes de contacto blandas, método de trazado de Rayos.</font></p>  <hr size="1"><B>     <p><font face="Verdana" size="2">ABSTRACT</font></p> </B>     <p><font face="Verdana" size="2"><B>Purpose:</b>To evaluate the impact of disposable  soft contact lenses upon visual performance by comparing the optical aberrations  of myopic eyes with and without the use of contact lenses.</font><B><font size="2" face="Verdana">    <br> Method:</font></B><font size="2" face="Verdana"> The optical  aberrations of a set of 18 eyes were measured by a laser ray tracing system, an  objective measurement method, enabling comparison of the findings of the naked  eye, the eye plus a test lens, and the eye plus a disposable contact  lens.</font><B><font size="2" face="Verdana">    <br> Results:</font></B><font size="2" face="Verdana"> There was a large  variability among subjects, but the general tendency was that test lenses did  not modify aberrations, whereas contact lenses tended to increase the ocular  aberrations for large pupils by an average of 40%. There was a lower increase  for smaller pupils.</font><B><font size="2" face="Verdana">    <br> Conclusion:</font></B><font face="Verdana" size="2"> This study  predicts there will be no significant adverse effects on the quality of vision  from the use of disposable contact lenses worn under daylight conditions, but a  small decline in night vision </font> <i> <font size="2" face="Verdana">(Arch Soc Esp Oftalmol  2006; 81: 575-580).</font></p> </i> <B>     <p><font size="2" face="Verdana">Key words:</font></B><font size="2" face="Verdana"> Aberrations, soft  contact lenses, Laser Ray Tracing.</font></p> <B>   <hr size="1">       <p>&nbsp;</p>        <p><font face="Verdana">Introducción</font></p> </B>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">La ametropía es actualmente corregida mediante gafas,  lentes de contacto (LC) o cirugía refractiva. Cada método tiene ventajas e  inconvenientes que el especialista debe dar a conocer al paciente para que éste  haga la elección más adecuada a sus necesidades. Como la corrección de ametropía  (desenfoque y/o astigmatismo) es directa por cualquiera de los métodos  mencionados, es importante tener criterios para elegir la mejor solución para  cada individuo concreto.</font></p>      <p><font face="Verdana" size="2">Para cantidades moderadas de ametropía, las gafas  convencionales no modifican significativamente las aberraciones ópticas porque  tienen una apertura numérica relativamente baja (aberraciones bajas), y al no  estar en contacto directo con el ojo no modifica su geometría. Sin embargo, las  técnicas de cirugía refractiva parecen incrementar las aberraciones ópticas del  ojo por un factor de 2 (1) o incluso por un 4 (2). Respecto a las LC, recientes  estudios demuestran que existen diversos factores que afectan a la calidad  visual, como la capa de lágrima, la dinámica de la misma lente, el tiempo, la  edad, la hidratación y flexibilidad de la lente, así como el proceso de  fabricación de la lente y los cambios de las aberraciones oculares con  acomodación (3,4).</font></p>      <p><font face="Verdana" size="2">Existen pocos estudios que analicen la calidad óptica  del sistema óptico formado por el ojo más la lente de contacto con parámetros  objetivos, los cuales se basan en la Función de Transferencia de Modulación  (5,6), hallada mediante el método de doble paso (7,8). La mayoría de los  estudios publicados previamente evalúan la compensación óptica mediante LC  utilizando sólo técnicas subjetivas, como son la agudeza visual (AV) o la  función de sensibilidad al contraste (SFC). Además, en su mayor parte estudian  únicamente L.C. rígidas permeables al gas (RPG). Existe una alta variabilidad en  cuanto a los resultados publicados en la literatura, obteniéndose en general  diferencias no significativas. En algunos de estos estudios se concluye que las  RPG producen una mejora de la calidad de visión gracias a que provocan una  reducción de las aberraciones corneales, mientras que para las lentes blandas  sólo unos pocos refieren una ligera mejoría con las LC. Otros autores exponen  que las mejoras en la calidad de visión con LC son variables y que dependen en  cierta medida de la naturaleza de ésta (9-19).</font></p>      <p><font face="Verdana" size="2">El Departamento de Imagen y Visión en el Instituto de  Óptica (CSIC, Madrid, España) es reconocido internacionalmente por sus  contribuciones en el campo de la óptica fisiológica y visión. Varios métodos  desarrollados en este laboratorio han sido aplicados con éxito en la medición de  la calidad óptica del ojo en vivo, en estudios básicos y clínicos. Uno de estos  métodos es el método de Trazado Rayos Láser (TRL), que mide objetivamente las  aberraciones opticas (9) del ojo, y el cuál ha sido utilizado en este  estudio.</font></p>      <p>&nbsp;</p>      <p><font face="Verdana" size="3"><b>Sujetos, material y métodos</b></font></p>      <p><font face="Verdana" size="2">Esta investigación cumple los postulados de la  Declaración de Helsinki y todos los sujetos firmaron un informe con su  consentimiento después de la explicación de la naturaleza y posibles  consecuencias del estudio.</font></p>  <B>     <p><font face="Verdana" size="2">    <br> Material</font></p> </B>     <p><font face="Verdana" size="2">En este estudio se han empleado LC desechables de  reemplazo semanal en caso de uso prolongado o de reemplazo quincenal si su uso  es diario. Las LC empleadas fueron hidrofílicas, de humedad 58% y radios de 8,30  a 8,70 mm.</font></p>  <B>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">    <br> Sujetos</font></p> </B>     <p><font face="Verdana" size="2">Los sujetos fueron 10 voluntarios miopes (18 ojos)  sin desórdenes oculares que pudieran producir intolerancia a las lentes de  contacto. 6 mujeres y 4 hombres, con edades entre 22 y 27 años. Los errores  refractivos comprendían entre &#8211;0,75 y &#8211;7,00 D. La <a href="/img/revistas/aseo/v81n10/t04-01.gif" target="_blank">tabla I</a> resume los datos para  estos sujetos, ordenados por valor ascendente de miopía.</font></p>      <p>    <br> <B><font face="Verdana" size="2">Metodología</font></p>  </B><i>      <p><font face="Verdana" size="2">Examen ocular</font></p> </i>      <p><font face="Verdana" size="2">Los sujetos fueron sometidos a una exploración  optométrica y oftálmica que incluía: medición de la ametropía, adaptación  contactológica, y estudio de la salud ocular (medida de la presión ocular,  estudio con la lámpara de hendidura, medida del ángulo iridocorneal, estudio de  fondo de ojo en los casos necesarios. antecedentes, altas ametropías, etc). El  tiempo transcurrido desde la adaptación de las lentes al experimento fue de al  menos de dos días.</font></p>      <p>    <br> <i> <font face="Verdana" size="2">Medición de la aberración ocular  objetiva</font></p>  </i>      <p><font face="Verdana" size="2">La calidad óptica de cada ojo fue medida por el TRL,  método desarrollado por Insitituto de Óptica (CSIC) para medir aberraciones  ópticas (9) objetivamente. Se envía un haz láser estrecho (rayo) a distintas  localizaciones en la retina y se recoge las posiciones del punto de luz formado  por cada haz, las diferencias entre las posiciones teóricas y las recogidas nos  da una estimación de la aberración que sufre el frente de onda de la luz al  atravesar el ojo (1,14).</font></p>      ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">Las medidas fueron realizadas al menos en dos de las  siguientes condiciones para cada ojo:</font></p>      <p><font face="Verdana" size="2">1. Sin corrección (ojo desnudo), excepto en sujetos  con más de 4 dioptrías, ya que valores más altos de miopía podrían exceder el  rango de medida del sistema TRL.</font></p>      <p><font face="Verdana" size="2">2. Con lentes de prueba: nos permiten tener una idea  aproximada de como sería la calidad óptica con gafas, debido a los distintos  modelos disponibles se prefiere utilizar las lentes de prueba para uniformizar  resultados. Fue realizado en la mayor parte de los casos, y cuando el primer  caso no era posible.</font></p>      <p><font face="Verdana" size="2">3. LC a estudiar, en todos los casos.</font></p>      <p><font face="Verdana" size="2">En cada situación las medidas fueron repetidas 5  veces.</font></p>      <p><font face="Verdana" size="2">Los sujetos no llevaron LC durante al menos 48 horas  antes de las medidas. Las LC blandas fueron colocadas como mínimo en los 30  minutos previos a la medición, para una completa estabilización en el  ojo.</font></p>      <p>    <br> <i> <font face="Verdana" size="2">Análisis de datos</font></p>  </i>      <p><font face="Verdana" size="2">La aberración de onda puede describirse como una  expansión polinómica de Zernike hasta 7<sup>  °</sup>  orden (35 coeficientes). El  conjunto promedio de coeficientes de Zernike fue calculado ajustando los datos  de las cinco mediciones de cada situación, estos coeficientes describen entonces  las aberraciones ópticas de los ojos analizados. La raíz cuadrática media (RMS)  de los coeficientes (RMS del error del frente de onda) fue utilizada como  métrica para evaluar la calidad óptica global del ojo, o del sistema óptico  formado por el ojo más lente (de contacto o de prueba).</font></p>      <p><font face="Verdana" size="2">Las mediciones fueron realizadas para una pupila de  6,5 mm conseguida mediante dilatación con cicloplegico, pero los coeficientes de  Zernike fueron recalculados para una pupila de 3 mm.</font></p>      ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">Para evaluar si los resultados son estadísticamente  significativos se utilizo un test T de muestras pareadas, con un nivel de  confianza del 95% (a</font><font  size=2><font face=Verdana size=2>=0,05).</font></font></p>      <p>&nbsp;</p>      <p><font face="Verdana"><B>Resultados</B></font></p>      <p><font face=Verdana size=2>La <a href="#Fig 1">figura 1 </a>muestra la RMS del error del frente de  onda, excluyendo desenfoque y astigmatismo (es decir, sólo se considera la  aberración de 3.<sup>  er</sup>  orden y superiores), para los 18 ojos y para  pupila de 6,5 mm: sin corrección (SC, barras blancas); con lentes de prueba (LP,  barras negras) y con LC (LC, barras con líneas grises diagonales). Los datos son  ordenados en función de la miopía (en orden ascendente). Los ojos de 1 a 16  tienen errores esféricos miópicos entre 0,75 y 3,50 D, mientras los ojos 17 y 18  tienen errores hasta 7 D, como se puede ver en la <a target="_blank" href="/img/revistas/aseo/v81n10/t04-01.gif">tabla I</a> anteriormente  presentada.</p>      <p align="center"> <a name="Fig 1"> <img border="0" src="/img/revistas/aseo/v81n10/f04-01.gif" width="600" height="437"></a>    <BR><B>Fig.  1.</b>Aberraciones de 3.<sup>  er</sup>  orden y superiores: error de frente de  onde RMS para aberraciones    <br> de 3.<sup>  er</sup>  orden y superiores para un  diámetro de pupila de 6,5 mm y para 3 condiciones:    <br> sin corrección (blanco), con  lentes de prueba (negro), y con LC (líneas diagonales grises).    <br> Los datos son  ordenados por miopía ascendente.</p>  </font><font  size=2><font face=Verdana size=2>     <p>    ]]></body>
<body><![CDATA[<br> Los resultados muestran una alta variabilidad entre  ojos en las aberraciones medidas. En promedio, las lentes de prueba tienden a  disminuir ligeramente las aberraciones ópticas del ojo y a incrementar la  calidad óptica. Para LC se observa diferentes grupos: Ojos (1-8) con errores  refractivos menos o igual que 2,00 D, las LC incrementan las aberraciones en  todos los casos. Por el contrario, el 70% de los ojos con un error refractivo de  más de 2,50 D (ojos 9-18) mejora su calidad óptica con LC Aplicando el test T  para muestras pareadas obtenemos un p-valor=0,0092 cuando comparamos las  distribuciones de OD y LP, y p-valor=0,0229 para las distribuciones de OD y LC,  ambas mayor que </font><font face=SymbolPS size=2> <font face=Verdana size=2>a=0,05  (95% de confianza), con lo cuál los resultados son estadísticamente  significativos.</p>      <p>En la <a href="/img/revistas/aseo/v81n10/t04-02.gif" target="_blank">tabla II</a> se presenta los resultados promedio  para distintas aberraciones.</p>      <p>Como se esperaba, las lentes de prueba no modifican  significativamente la aberración del ojo, los resultados muestran una ligera  mejora. Por otra parte, las LC incrementan las aberraciones ópticas en un 40% en  promedio. Sin embargo, es importante notar que las desviaciones estándar son  siempre significativamente mayores que la media, lo cual indica la alta  variabilidad y comportamientos no similares en los ojos individuales (20). Hay  también una fuerte dependencia del tamaño de pupila: mientras el incremento en  aberraciones ópticas es potencialmente más importante para grandes pupilas (6,5  mm), los valores encontrados para pupilas más pequeñas (3 mm) son mucho  menores.</p>      <p>&nbsp;</p>      <p></font></font></font><B><font face="Verdana">Discusión</font></p>  </B> <font face=SymbolPS size=2> <font  size=2> <font face=Verdana size=2>     <p>Los resultados obtenidos con el método TRL predicen  un efecto en la calidad de visión despreciable con LC desechables bajo  condiciones de luz diurna (diámetro de pupila no mucho mayor que 3 mm), pero un  moderado descenso de la calidad de visión durante visión nocturna o bajos  niveles de iluminación (pupilas alrededor de 6,5 mm), mientras que las lentes de  prueba no modifican la calidad visual. Sin embargo es importante señalar la alta  variabilidad de resultados entre los distintos ojos (20). Este estudio debe ser  considerado como un experimento piloto, y tendrá que ser llevado a cabo un  trabajo posterior para determinar las fuentes de tan grandes diferencias,  incluyendo un número mayor de pacientes y LC de distintas marcas y con más  parámetros para realizar adaptaciones más precisas.</p>      <p>&nbsp;</p>      <p></font></font></font><font face=Verdana><B>Reconocimientos</p>  </B> </font><font face=SymbolPS size=2> <font face=Verdana size=2>     <p>Este trabajo ha sido financiado en parte por la CICYT  (Ministerio de Educación y Ciencia), acción TIC 98-0925-CO2-01. Los autores  quieren agradecer la colaboración de la Unidad Asociada de Investigación IOBA  (Universidad de Valladolid) &#8212; Instituto de Óptica&#8212; (CSIC), la Unidad de  Contactología del Centro de Especialidades Oftalmológicas de Madrid y a Lourdes  Llorente (Instituto de Óptica, CSIC) por su asistencia técnica durante el  estudio.</p>      <p>&nbsp;</p>      ]]></body>
<body><![CDATA[<p></font></font><font face=Verdana><b>Bibliografía</p>  </b></font><font face=Verdana size=2>      <!-- ref --><p>1. Moreno-Barriuso E, Lloves JM, Marcos S, Navarro R, Llorente L, Barbero S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci 2001; 42: 1396-1403.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881386&pid=S0365-6691200600100000400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Mrochen M, Kaemmerer M, Mierdel P, Seiler T. Increased higher-order optical aberrations after laser refractive surgery: a problem of subclinical decentration. J Cataract Refract Surg 2001; 27: 362-369.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881387&pid=S0365-6691200600100000400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Dietze HH, Cox MJ. Correcting ocular spherical aberration with soft contact lenses. J Opt Soc Am A Opt Image Sci Vis 2004; 21: 473-485.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881388&pid=S0365-6691200600100000400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Chateau N, Blanchard A, Baude D. Influence of myopia and aging on the optimal spherical aberration of soft contact lenses. J Opt Soc Am A Opt Image Sci Vis 1998; 15: 2589-2596.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881389&pid=S0365-6691200600100000400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. Lorente A, Pons AM, Malo J, Artigas JM. Standard criterion for fluctuations of modulation transfer function in the human eye: application to disposable contact lenses. Ophthalmic Physiol Opt 1997; 17: 267-272.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881390&pid=S0365-6691200600100000400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. Pons AM, Lorente A, Albarran C, Montes R, Artigas JM. Characterizacion of the visual performance with soft daily wear disposable contact lenses. Ophthalmic Physiol Opt 1998; 18: 40-48.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881391&pid=S0365-6691200600100000400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. Torrents A, Navarro R, Losada MA. El método de doble paso para evaluar la calidad óptica de la imagen retiniana. Ver y Oir 1995; 97: 29-36. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881392&pid=S0365-6691200600100000400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Artal P, Marcos S, Navarro R, Williams DR. Odd aberrations and double-pass measurements of retinal image quality. J Opt Soc Am A 1995; 12: 195-201.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881393&pid=S0365-6691200600100000400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Tomlinson A, Mann G. An analysis of visual performance with soft contact lens and spectacle correction. Ophthalmic Physiol Opt 1985; 5: 53-57. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881394&pid=S0365-6691200600100000400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Hong X, Himebaugh N, Thibos LN. On-eye evaluation of optical performance of rigid and soft contact lenses. Optom Vis Sci 2001; 78: 872-880. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881395&pid=S0365-6691200600100000400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11. Cox IG, Holden BA. Soft contact lens-induced longal spherical aberration ad its effect on contrast sensitivity. Optom Vis Sci 1990; 67: 679-683.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881396&pid=S0365-6691200600100000400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Lorente A, Albarran C, Montes R, Pons AM, Artigas JM. Contact lenses: do they really change the optical performance? Cont Lens Anterior Eye 1997; 20: 57-61.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881397&pid=S0365-6691200600100000400012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Navarro R, Losada MA. Aberration and relative efficiency of light pencils in the living human eye. Optom Vis Sci 1997; 74: 540-547.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881398&pid=S0365-6691200600100000400013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Atchinson DA. Aberrations associated with rigid contact lenses. J Opt Soc Am A 1995; 12: 2267-2273.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881399&pid=S0365-6691200600100000400014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Dorronsoro C, Barbero S, Llorente L, Marcos S. On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry. Optom Vis Sci 2003; 80: 115-125.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881400&pid=S0365-6691200600100000400015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Collins MJ, Brown B, Atchison DA, Newman SD. Tolerance to spherical aberration induced by rigid contact lenses. Ophthalmic Physiol Opt 1992; 12: 24-28.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881401&pid=S0365-6691200600100000400016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Hammer RM, Holden BA. Spherical aberration of aspheric contact lenses on eye. Optom Vis Sci 1994; 71: 522-528.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881402&pid=S0365-6691200600100000400017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Kirkpatrick DL, Roggenkamp R. Effects of soft contact lenses contrast sensivity. Am Optom Phyisiol Opt 1985; 62: 407-412.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881403&pid=S0365-6691200600100000400018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19. Moreno-Barriuso E, Navarro R. Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye. J Opt Soc Am A Opt Image Sci Vis 2000; 17: 974-977.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881404&pid=S0365-6691200600100000400019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. Gispets I, Parcerisas J. ¿Cambian las aberraciones con el uso de lentes de contacto? In: Gispets I, Parcerisas J. Aberraciones oculares: aspectos clínicos. Madrid: ICM; 2005; 53-60.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=881405&pid=S0365-6691200600100000400020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>&nbsp;</p>      <p>&nbsp;</p>  </font>     <p> <a href="#inicio" name="Fin"> <img border="0" src="/img/revistas/aseo/v81n10/seta.gif" width="15" height="17"></a><font face="Verdana" size="2"><b>Dirección  para correspondencia:    <br> </b>Vanesa Blázquez Sánchez    <br> C/ Antonio López, 149, 1º. B    <br> 28026 Madrid    <br> España    <br> E-mail: <a href="mailto:ltqb347@ifa.cetef.scic.es">ltqb347@ifa.cetef.scic.es</a></font></p>       <p><font face="Verdana" size="2">Recibido: 13.9.04.    ]]></body>
<body><![CDATA[<br> Aceptado: 23.10.06.</font></p>     ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moreno-Barriuso]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Lloves]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Marcos]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Navarro]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Llorente]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Barbero]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2001</year>
<volume>42</volume>
<page-range>1396-1403</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mrochen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kaemmerer]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Mierdel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Seiler]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Increased higher-order optical aberrations after laser refractive surgery: a problem of subclinical decentration]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2001</year>
<volume>27</volume>
<page-range>362-369</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dietze]]></surname>
<given-names><![CDATA[HH]]></given-names>
</name>
<name>
<surname><![CDATA[Cox]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correcting ocular spherical aberration with soft contact lenses]]></article-title>
<source><![CDATA[J Opt Soc Am A Opt Image Sci Vis]]></source>
<year>2004</year>
<volume>21</volume>
<page-range>473-485</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chateau]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Blanchard]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Baude]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of myopia and aging on the optimal spherical aberration of soft contact lenses]]></article-title>
<source><![CDATA[J Opt Soc Am A Opt Image Sci Vis]]></source>
<year>1998</year>
<volume>15</volume>
<page-range>2589-2596</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lorente]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pons]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Malo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Artigas]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Standard criterion for fluctuations of modulation transfer function in the human eye: application to disposable contact lenses]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>1997</year>
<volume>17</volume>
<page-range>267-272</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pons]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Lorente]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Albarran]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Montes]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Artigas]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterizacion of the visual performance with soft daily wear disposable contact lenses]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>1998</year>
<volume>18</volume>
<page-range>40-48</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torrents]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Navarro]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Losada]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[El método de doble paso para evaluar la calidad óptica de la imagen retiniana]]></article-title>
<source><![CDATA[Ver y Oir]]></source>
<year>1995</year>
<volume>97</volume>
<page-range>29-36</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Artal]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Marcos]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Navarro]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Odd aberrations and double-pass measurements of retinal image quality]]></article-title>
<source><![CDATA[J Opt Soc Am A]]></source>
<year>1995</year>
<volume>12</volume>
<page-range>195-201</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tomlinson]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mann]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An analysis of visual performance with soft contact lens and spectacle correction]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>1985</year>
<volume>5</volume>
<page-range>53-57</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hong]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Himebaugh]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Thibos]]></surname>
<given-names><![CDATA[LN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On-eye evaluation of optical performance of rigid and soft contact lenses]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2001</year>
<volume>78</volume>
<page-range>872-880</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cox]]></surname>
<given-names><![CDATA[IG]]></given-names>
</name>
<name>
<surname><![CDATA[Holden]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Soft contact lens-induced longal spherical aberration ad its effect on contrast sensitivity]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>1990</year>
<volume>67</volume>
<page-range>679-683</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lorente]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Albarran]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Montes]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pons]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Artigas]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Contact lenses: do they really change the optical performance?]]></article-title>
<source><![CDATA[Cont Lens Anterior Eye]]></source>
<year>1997</year>
<volume>20</volume>
<page-range>57-61</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Navarro]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Losada]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aberration and relative efficiency of light pencils in the living human eye]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>1997</year>
<volume>74</volume>
<page-range>540-547</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Atchinson]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aberrations associated with rigid contact lenses]]></article-title>
<source><![CDATA[J Opt Soc Am A]]></source>
<year>1995</year>
<volume>12</volume>
<page-range>2267-2273</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dorronsoro]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Barbero]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Llorente]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Marcos]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2003</year>
<volume>80</volume>
<page-range>115-125</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collins]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Atchison]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Newman]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tolerance to spherical aberration induced by rigid contact lenses]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>1992</year>
<volume>12</volume>
<page-range>24-28</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hammer]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Holden]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Spherical aberration of aspheric contact lenses on eye]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>1994</year>
<volume>71</volume>
<page-range>522-528</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kirkpatrick]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Roggenkamp]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of soft contact lenses contrast sensivity]]></article-title>
<source><![CDATA[Am Optom Phyisiol Opt]]></source>
<year>1985</year>
<volume>62</volume>
<page-range>407-412</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moreno-Barriuso]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Navarro]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye]]></article-title>
<source><![CDATA[J Opt Soc Am A Opt Image Sci Vis]]></source>
<year>2000</year>
<volume>17</volume>
<page-range>974-977</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gispets]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Parcerisas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[¿Cambian las aberraciones con el uso de lentes de contacto?]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Gispets]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Parcerisas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Aberraciones oculares: aspectos clínicos]]></source>
<year>2005</year>
<page-range>53-60</page-range><publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[ICM]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
