<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1130-1473</journal-id>
<journal-title><![CDATA[Neurocirugía]]></journal-title>
<abbrev-journal-title><![CDATA[Neurocirugía]]></abbrev-journal-title>
<issn>1130-1473</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Española de Neurocirugía]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1130-14732011000300002</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Fijación vertebral posterior guiada por neuronavegación: Experiencia en 121 casos]]></article-title>
<article-title xml:lang="en"><![CDATA[Posterior spinal instrumentation image guided and assisted by neuronavigation: Experience in 120 cases]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Florensa]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cardiel]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bescós]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Tardáguila]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Plans]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Domínguez]]></surname>
<given-names><![CDATA[C.J.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Colet]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital Germans Trias i Pujol Servicio de Neurocirugía ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Centro Médico Teknon  ]]></institution>
<addr-line><![CDATA[Barcelona ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<volume>22</volume>
<numero>3</numero>
<fpage>224</fpage>
<lpage>234</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S1130-14732011000300002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S1130-14732011000300002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S1130-14732011000300002&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Introducción. Los autores aportan una serie de 121 casos de instrumentación vertebral posterior realizadas desde septiembre del 2008 a diciembre del 2010 mediante la utilización de Fluoro 2D y TC asistida con neuronavegador Vector Visión o Kolibri. (Brain LAB, Feldkirchen, Germany). Material. La muestra fue de 68 varones y 53 mujeres con edades comprendidas entre 24 y 75 años con una media de 50,35 años, todos ellos con indicación para una instrumentación vertebral posterior por distintas patologías. Método. A todos se les realizó una TC previo al procedimiento según protocolo específico de adquisición de imagen para navegación, estas se fusionaron en el navegador con las adquiridas en el quirófano con un Fluoro 2D, lo cual permitió realizar una reconstrucción de alta calidad y así poder navegar de forma real-virtual. Para valorar los resultados se realizó una TC postoperatorio y se clasificó la posición del implante según la escala tomográfica de Heary. Se valoró también el tiempo de calibración del material y número de disparos con el Fluoro-2D. Los resultados clínicos se valoraron con las escalas de VAS, Oswestry y JOA (L) así como el grado de satisfacción con el procedimiento y aceptación del mismo. Resultados. Se implantaron un total de 580 tornillos distribuidos en 62 cervicales (24 en C1-C2), 38 dorsales, 370 lumbares y 110 sacros. Se realizó cirugía abierta en 42 casos, MIS 28 y percutánea en 51. La precisión del implante fue del 98,45% con una desviación global del 1,55% que según escala de Heary se distribuyeron en Grado II: 2 (1 cervical, 1 lumbar), grado III: 4 (1 cervical, 2 dorsales, 1 lumbar), grado IV: 3 (1 cervical, 2 lumbares). Tiempo medio global de calibración por procedimiento fue de 2'49'' y la media de exposición fluoroscópica fue de 1 disparo a nivel cervical y dorsal y 2 lumbar. La valoración clínica al mes de 121 pacientes fue de 8.6/3.0 en el VAS, 68.0% / 23.0% en Oswestry y 6,4/13,1 en JOA (L), dichos parámetros se mantuvieron estables a los 3 meses en 100 pacientes y a los 6 meses en 87 pacientes respectivamente, el grado de satisfacción entre completamente y muy satisfechos fue en el 94.9% y aceptarían de nuevo el tratamiento más de un 94%. Conclusión. La navegación con fluoro-2D-TC es una técnica de muy alta precisión que disminuye complicaciones, el número de reintervenciones, la exposición de irradiación y el tiempo quirúrgico.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction. The authors present the results of a series of 121 cases of posterior vertebral fixation carried out from Sept 2008 to Sept 2010 using Flouro 2D-TC assisted Vector Vision o Kolibri navigator. (Brain LAB, Feldkirchen, Germany). Material. The sample included 68 males and 53 females. Age range was 24-75 with an average of 50.35., all with indication for instrumentation by different pathologies. Method. Patients presenting vertebral lesions of varying ethiology and lesion level with vertebral posterior fixation indication were included in the study. All underwent a CT before surgery, according to navigation protocol, and the images obtained were merged in the navigator with those obtained in the operating room with a Flouro 2D, which allowed a high quality 3D reconstruction to be performed and thus the capacity to navigate in a real-virtual manner. To evaluate the results of the implant a post-op CT was performed and the position of the implant was defined according to the Heary scale. The calabration time of the material was also evaluated, number of shots with the Flouro-2D, and for clinical evaluation VAS scales were employed, Oswestry and JOA (L), as well as the degree of satisfaction and acceptance of the procedure. Results. A total of 580 screws were implanted, distributed in 62 cervicals of which 24 were in C1-C2, 38 dorsals, 370 lumbar and 110 sacral. Open surgery was performed in 42 cases, MIS in 28 and percutaneous in 51. The presision of the implant was 98.45% with a global deviation of 1.55%, that according to the Heary scale was distributed in grade ll: 2 (1 cervical, 1 lumbar) grade lll: 4 (1 cervical, 2 dorsal, 1 lumbar), grade IV: 3 (1 cervical, 2 lumbar). General average time of calibration per procedure was 2 min. 49 seconds and the mean flouroscopic exposure was one shot at cervical and dorsal and two shots at lumbar level. The clinical evaluation at one month of 121 patients was 8.6/3.0 in the VAS, 68.0% / 23.0% in Oswestry and 6.4/13.1 in JOA (L), with those parameters remaining stable at 3 months in 100 and at 6 months in 87 patients respectively, and the degree of satisfaction between being completely and very satisfied with the procedure was 94.9%, and those who would submit to another treatment was more than 94%. Conclusion. Navigation with Flouro-2D-CT is a high precision technique that reduces complications of varying severity according to the level operated well as number of reinterventions, radiation exposure and surgical time.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Navegación vertebral]]></kwd>
<kwd lng="es"><![CDATA[Cirugía guiada]]></kwd>
<kwd lng="es"><![CDATA[Fijación vertebral percutánea]]></kwd>
<kwd lng="es"><![CDATA[Tornillos pediculares]]></kwd>
<kwd lng="en"><![CDATA[Vertebral navigation]]></kwd>
<kwd lng="en"><![CDATA[Guided surgery]]></kwd>
<kwd lng="en"><![CDATA[Percutaneous vertebral fixation]]></kwd>
<kwd lng="en"><![CDATA[Pedicle screws]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p>&nbsp;</p>     <p>&nbsp;</p>     <p><a name="top"></a><font face="Verdana" size="4"><b>Fijaci&oacute;n vertebral posterior guiada por neuronavegaci&oacute;n. Experiencia en 121 casos</b></font></p>     <p><font face="Verdana" size="4"><b>Posterior spinal instrumentation image guided and assisted by neuronavigation. Experience in 120 cases</b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>R. Florensa*; J. Mu&ntilde;oz*; I. Cardiel; A. Besc&oacute;s; M. Tard&aacute;guila; G. Plans*; C.J. Dom&iacute;nguez y S. Colet</b></font></p>     <p><font face="Verdana" size="2">Servicio de Neurocirug&iacute;a Hospital Germans Trias i Pujol. Centro M&eacute;dico Teknon*. Barcelona.</font></p>     <p><font face="Verdana" size="2"><a href="#back">Direcci&oacute;n para correspondencia</a></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p> <hr size="1">     <p><font face="Verdana" size="2"><b>RESUMEN</b></font></p>     <p><font face="Verdana" size="2"><b>Introducci&oacute;n.</b> Los autores aportan una serie de 121 casos de instrumentaci&oacute;n vertebral posterior realizadas desde septiembre del 2008 a diciembre del 2010 mediante la utilizaci&oacute;n de Fluoro 2D y TC asistida con neuronavegador Vector Visi&oacute;n o Kolibri. (Brain LAB, Feldkirchen, Germany).    <br><b>Material.</b> La muestra fue de 68 varones y 53 mujeres con edades comprendidas entre 24 y 75 a&ntilde;os con una media de 50,35 a&ntilde;os, todos ellos con indicaci&oacute;n para una instrumentaci&oacute;n vertebral posterior por distintas patolog&iacute;as.    <br><b>M&eacute;todo.</b> A todos se les realiz&oacute; una TC previo al procedimiento seg&uacute;n protocolo espec&iacute;fico de adquisici&oacute;n de imagen para navegaci&oacute;n, estas se fusionaron en el navegador con las adquiridas en el quir&oacute;fano con un Fluoro 2D, lo cual permiti&oacute; realizar una reconstrucci&oacute;n de alta calidad y as&iacute; poder navegar de forma real-virtual. Para valorar los resultados se realiz&oacute; una TC postoperatorio y se clasific&oacute; la posici&oacute;n del implante seg&uacute;n la escala tomogr&aacute;fica de Heary. Se valor&oacute; tambi&eacute;n el tiempo de calibraci&oacute;n del material y n&uacute;mero de disparos con el Fluoro-2D. Los resultados cl&iacute;nicos se valoraron con las escalas de VAS, Oswestry y JOA (L) as&iacute; como el grado de satisfacci&oacute;n con el procedimiento y aceptaci&oacute;n del mismo.    <br><b>Resultados.</b> Se implantaron un total de 580 tornillos distribuidos en 62 cervicales (24 en C1-C2), 38 dorsales, 370 lumbares y 110 sacros. Se realiz&oacute; cirug&iacute;a abierta en 42 casos, MIS 28 y percut&aacute;nea en 51. La precisi&oacute;n del implante fue del 98,45% con una desviaci&oacute;n global del 1,55% que seg&uacute;n escala de Heary se distribuyeron en Grado II: 2 (1 cervical, 1 lumbar), grado III: 4 (1 cervical, 2 dorsales, 1 lumbar), grado IV: 3 (1 cervical, 2 lumbares). Tiempo medio global de calibraci&oacute;n por procedimiento fue de 2'49'' y la media de exposici&oacute;n fluorosc&oacute;pica fue de 1 disparo a nivel cervical y dorsal y 2 lumbar. La valoraci&oacute;n cl&iacute;nica al mes de 121 pacientes fue de 8.6/3.0 en el VAS, 68.0% / 23.0% en Oswestry y 6,4/13,1 en JOA (L), dichos par&aacute;metros se mantuvieron estables a los 3 meses en 100 pacientes y a los 6 meses en 87 pacientes respectivamente, el grado de satisfacci&oacute;n entre completamente y muy satisfechos fue en el 94.9% y aceptar&iacute;an de nuevo el tratamiento m&aacute;s de un 94%.    <br><b>Conclusi&oacute;n.</b> La navegaci&oacute;n con fluoro-2D-TC es una t&eacute;cnica de muy alta precisi&oacute;n que disminuye complicaciones, el n&uacute;mero de reintervenciones, la exposici&oacute;n de irradiaci&oacute;n y el tiempo quir&uacute;rgico.</b></font></p>     <p><font face="Verdana" size="2"><b>Palabras clave:</b> Navegaci&oacute;n vertebral. Cirug&iacute;a guiada. Fijaci&oacute;n vertebral percut&aacute;nea. Tornillos pediculares.</font></p> <hr size="1">     <p><font face="Verdana" size="2"><b>SUMMARY</b></font></p>     <p><font face="Verdana" size="2"><b>Introduction.</b> The authors present the results of a series of 121 cases of posterior vertebral fixation carried out from Sept 2008 to Sept 2010 using Flouro 2D-TC assisted Vector Vision o Kolibri navigator. (Brain LAB, Feldkirchen, Germany).    ]]></body>
<body><![CDATA[<br><b>Material.</b> The sample included 68 males and 53 females. Age range was 24-75 with an average of 50.35., all with indication for instrumentation by different pathologies.    <br><b>Method.</b> Patients presenting vertebral lesions of varying ethiology and lesion level with vertebral posterior fixation indication were included in the study. All underwent a CT before surgery, according to navigation protocol, and the images obtained were merged in the navigator with those obtained in the operating room with a Flouro 2D, which allowed a high quality 3D reconstruction to be performed and thus the capacity to navigate in a real-virtual manner. To evaluate the results of the implant a post-op CT was performed and the position of the implant was defined according to the Heary scale. The calabration time of the material was also evaluated, number of shots with the Flouro-2D, and for clinical evaluation VAS scales were employed, Oswestry and JOA (L), as well as the degree of satisfaction and acceptance of the procedure.    <br><b>Results.</b> A total of 580 screws were implanted, distributed in 62 cervicals of which 24 were in C1-C2, 38 dorsals, 370 lumbar and 110 sacral. Open surgery was performed in 42 cases, MIS in 28 and percutaneous in 51. The presision of the implant was 98.45% with a global deviation of 1.55%, that according to the Heary scale was distributed in grade ll: 2 (1 cervical, 1 lumbar) grade lll: 4 (1 cervical, 2 dorsal, 1 lumbar), grade IV: 3 (1 cervical, 2 lumbar). General average time of calibration per procedure was 2 min. 49 seconds and the mean flouroscopic exposure was one shot at cervical and dorsal and two shots at lumbar level. The clinical evaluation at one month of 121 patients was 8.6/3.0 in the VAS, 68.0% / 23.0% in Oswestry and 6.4/13.1 in JOA (L), with those parameters remaining stable at 3 months in 100 and at 6 months in 87 patients respectively, and the degree of satisfaction between being completely and very satisfied with the procedure was 94.9%, and those who would submit to another treatment was more than 94%.    <br><b>Conclusion.</b> Navigation with Flouro-2D-CT is a high precision technique that reduces complications of varying severity according to the level operated well as number of reinterventions, radiation exposure and surgical time.</font></p>     <p><font face="Verdana" size="2"><b>Key words:</b> Vertebral navigation. Guided surgery. Percutaneous vertebral fixation. Pedicle screws.</font></p> <hr size="1">     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p><font face="Verdana" size="2">La instrumentaci&oacute;n vertebral posterior es una t&eacute;cnica con alta eficacia o refrendada en la literatura para el tratamiento de patolog&iacute;as degenerativas, traum&aacute;ticas y tumorales. Se trata de una t&eacute;cnica avalada por un alto nivel de evidencia cient&iacute;fica, pero no exenta de complicaciones, siendo estas m&iacute;nimas en manos expertas pero que pueden conllevar gravedad importante seg&uacute;n el nivel de la intervenci&oacute;n. La desviaci&oacute;n de un tornillo<sup>7,8,17,23,34</sup> es la complicaci&oacute;n m&aacute;s reportada con porcentajes del 12 hasta un 40%, de los cuales solo entre un 4 y 12% dan sintomatolog&iacute;a cl&iacute;nica.</font></p>     <p><font face="Verdana" size="2">Cl&aacute;sicamente la instrumentaci&oacute;n posterior se ha realizado seg&uacute;n unas referencias anat&oacute;micas vertebrales 6 con el soporte del fluoroscopio 2D intra-operatorio. Con el objetivo de mejorar la precisi&oacute;n del implante, se han aportado diferentes m&eacute;todos como cirug&iacute;a guiada con Framless<sup>29</sup> a nivel cervical, cirug&iacute;a guiada con Fluoroscopio y TC<sup>9,36</sup>, RM<sup>8</sup>, monitorizaci&oacute;n neurofisiol&oacute;gica<sup>11</sup>, endoscopia asistida<sup>2</sup> y la detecci&oacute;n con ultrasonido<sup>22</sup> del trayecto de tornillo pedicular. Todos ellos permiten mejorar la precisi&oacute;n en la colocaci&oacute;n del implante pero ninguno ofrece una imagen real-virtual directa del trayecto de los tornillos hasta la introducci&oacute;n de la navegaci&oacute;n.</font></p>     <p><font face="Verdana" size="2">La navegaci&oacute;n, fue aplicada en la columna<sup>9,24</sup> a partir del a&ntilde;o 2000, pero debido a una limitaci&oacute;n de los software y hardware, a la lentitud del procedimiento, por una curva de aprendizaje dif&iacute;cil y por la relaci&oacute;n beneficio coste econ&oacute;mico, no fue integrada en el arsenal tecnol&oacute;gico para la cirug&iacute;a de columna. Desde el 2007 y despu&eacute;s de mejorar dichos aspectos, la navegaci&oacute;n ha experimentado una expansi&oacute;n de su uso. Se han descrito diferentes sistemas de navegaci&oacute;n para la fijaci&oacute;n de columna seg&uacute;n el m&eacute;todo y obtenci&oacute;n de im&aacute;genes radiol&oacute;gicas sea con Fluoro 2D-TC, Fluoro ISO C-3D, CT y RMN, esta &uacute;ltima la menos consolidada, siendo las diferencias de precisi&oacute;n entre ellos insignificantes<sup>34,26,15</sup>. (<a target="_blank" href="/img/revistas/neuro/v22n3/clinica2_tabla1.jpg">Tabla 1</a>).</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">El objetivo de este trabajo es presentar los resultados obtenidos, principalmente en cuanto a la precisi&oacute;n del implante en una serie prospectiva de 121 pacientes intervenidos por un mismo equipo entre el Servicio de Neurocirug&iacute;a del H.G.T.P. de Badalona y Centro M&eacute;dico Teknon.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Material y m&eacute;todo</b></font></p>     <p><font face="Verdana" size="2">Se trata de una muestra de 121 casos con indicaci&oacute;n de una instrumentaci&oacute;n vertebral posterior por diferentes patolog&iacute;as y niveles lesionales, utilizando para la navegaci&oacute;n el modelo Kolibr&iacute; y Vector Visi&oacute;n (Brain LAB, Feldkirchen, Germany).</font></p>     <p><font face="Verdana" size="2">A todos los pacientes se les realiz&oacute; un TC preoperatorio seg&uacute;n protocolo de navegaci&oacute;n, consistente en cortes axiales de 1,5mm tanto del nivel lesional como los inmediatos adyacentes con el objetivo de obtener im&aacute;genes limitadas al marco anat&oacute;mico de los espacios vertebrales a tratar. El paciente es colocado sobre la mesa de intervenciones en posici&oacute;n prono y una vez preparado el campo quir&uacute;rgico se marca con Rx el nivel lesional para colocar una pinza en la ap&oacute;fisis espinosa como soporte de las esferas reflectantes que ser&aacute;n captadas por la c&aacute;mara foto-&oacute;ptica del navegador. A continuaci&oacute;n con el fluoroscopio 2D, al cual se le adapta un Kit. de fluoroscopia con m&uacute;ltiples puntos referenciales, se adquiere una imagen en AP (<a href="#f1">Fig. 1</a>) que es transferida directamente al navegador, donde se comprueba la precisi&oacute;n anat&oacute;mica con un instrumento precalibrado y dicha precisi&oacute;n no debe superar los 1,5mm de desviaci&oacute;n. Se repite el mismo procedimiento en una proyecci&oacute;n lateral, a continuaci&oacute;n con las im&aacute;genes obtenidas se realiza una fusi&oacute;n (<a href="#f2">Fig. 2</a>) con las de la TC preoperatoria previamente introducidas al navegador obteniendo una imagen &oacute;sea tridimensional de alta calidad que nos permite navegar en tiempo real virtual (<a href="#f3">Fig. 3</a>).</font></p>     <p align="center"><font face="Verdana" size="2"><a name="f1"><img src="/img/revistas/neuro/v22n3/clinica2_f1.jpg" width="309" height="308"></a>    <br>Figura 1. <i>Rx. Ap. Con marcas referenciales y pinza    <br>en espinosa a intervenir.</i></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f2"><img src="/img/revistas/neuro/v22n3/clinica2_f2.jpg" width="479" height="383"></a>    ]]></body>
<body><![CDATA[<br>Figura 2. <i>Fusi&oacute;n imagenes TC y 2D intraoperatorias.</i></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f3"><img src="/img/revistas/neuro/v22n3/clinica2_f3.jpg" width="464" height="371"></a>    <br>Figura 3. <i>Navegaci&oacute;n en tiempo real-virtual.</i></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">A nivel cervical y dorsal, debido a las dificultades t&eacute;cnicas para la obtenci&oacute;n de buenas im&aacute;genes radiol&oacute;gicas s&oacute;lo se ha navegado con las im&aacute;genes de la TC preoperatoria necesitando tomar diferentes marcas anat&oacute;micas intraoperatorias en la v&eacute;rtebra o v&eacute;rtebras a intervenir seg&uacute;n protocolo incluido en el software del navegador (Fig.  <a href="#f4_1">4.1</a>, <a href="#f4_2">4.2</a>, <a href="#f4_3">4.3</a>).</font></p>     <p align="center"><font face="Verdana" size="2"><a name="f4_1"><img src="/img/revistas/neuro/v22n3/clinica2_f4.1.jpg" width="457" height="367"></a></font></p>     <p align="center"><font face="Verdana" size="2"><img src="/img/revistas/neuro/v22n3/clinica2_f4.jpg" width="1" height="1">    <br>Figura 4.1. <i>Navegaci&oacute;n articular en C1 con TC.</i></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="center"><font face="Verdana" size="2"><a name="f4_2"><img src="/img/revistas/neuro/v22n3/clinica2_f4.2.jpg" width="483" height="384"></a>    <br>Figura 4.2. <i>Navegaci&oacute;n pedicular en C2 con TC.</i></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f4_3"><img src="/img/revistas/neuro/v22n3/clinica2_f4.3.jpg" width="446" height="357"></a>    <br>Figura 4.3. <i>Navegaci&oacute;n pedicular en C5 con TC.</i></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">Para valorar los resultados de la precisi&oacute;n del implante se ha comparado las im&aacute;genes de planificaci&oacute;n de todos los pacientes, almacenadas en el disco duro del navegador, con los resultados de la TC postoperatoria realizada tambi&eacute;n seg&uacute;n protocolo de navegaci&oacute;n. Con la escala de Heary<sup>17</sup> (<a target="_blank" href="/img/revistas/neuro/v22n3/clinica2_tabla2.jpg">Tabla 2</a>) se ha clasificado la situaci&oacute;n del tornillo y adem&aacute;s tambi&eacute;n se ha valorado el tiempo del registro y calibraje del instrumental, el tiempo total del procedimiento, la exposici&oacute;n radiol&oacute;gica seg&uacute;n n&uacute;mero de vistas o disparos con el Fluoro 2D y la valoraci&oacute;n cl&iacute;nica mediante las escalas de VAS, &iacute;ndice de discapacidad de Oswesrty y JOA(L) as&iacute; como el grado de satisfacci&oacute;n con el procedimiento.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Resultados</b></font></p>     <p><font face="Verdana" size="2">La serie de 121 casos se distribuy&oacute; en 68 varones y 53 mujeres con una edad media de 50,35 a&ntilde;os (<a href="#t3">Tabla 3</a>). Se implantaron 580 tornillos (<a href="#t4">Tabla 4</a>) distribuidos en 480 lumbo-sacros, 38 dorsales y 62 cervicales , de estos &uacute;ltimos 24 en el segmento C1-C2. Todos los tornillos fueron pediculares a excepci&oacute;n de los 12 articulares de C1. La t&eacute;cnica quir&uacute;rgica empleada (<a href="#t5">Tabla 5</a>) fue abordaje percut&aacute;neo en 51 pacientes, MIS en 28 y 42 a cielo abierto empleando una fijaci&oacute;n r&iacute;gida en 44 casos y semi-r&iacute;gida o din&aacute;mica en 77 seg&uacute;n patolog&iacute;a del paciente.</font></p>     ]]></body>
<body><![CDATA[<p align="center"><font face="Verdana" size="2"><a name="t3"><img src="/img/revistas/neuro/v22n3/clinica2_tabla3.jpg" width="313" height="369"></a></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="t4"><img src="/img/revistas/neuro/v22n3/clinica2_tabla4.jpg" width="311" height="228"></a></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="t5"><img src="/img/revistas/neuro/v22n3/clinica2_tabla5.jpg" width="311" height="179"></a></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">La estancia media de los pacientes fue de 5,8 d&iacute;as, el tiempo medio quir&uacute;rgico de 3h 14m. y la exposici&oacute;n radiol&oacute;gica fue de 1 a 2 disparos para localizar el nivel en regi&oacute;n cervical y dorsal y 2 disparos en regi&oacute;n lumbar. El tiempo medio de registro del instrumental fue de 2'49''.</font></p>     <p><font face="Verdana" size="2">En la valoraci&oacute;n por TC postquir&uacute;rgica, seg&uacute;n escala de grados de Heary, 571 tornillos fueron intrapediculares sin violaci&oacute;n de pared, 6 con desviaci&oacute;n lateral externa y 3 con desviaci&oacute;n medial consider&aacute;ndose finalmente un 98,45% de fiabilidad de la planificaci&oacute;n con navegaci&oacute;n. Como complicaciones (<a href="#t6">Tabla 6</a>) una reintervenci&oacute;n por dolor radicular debido a una mala posici&oacute;n del tornillo a nivel cervical, 1 fractura de un tornillo lumbar y 3 casos de infecci&oacute;n quir&uacute;rgica.</font></p>     <p align="center"><font face="Verdana" size="2"><a name="t6"><img src="/img/revistas/neuro/v22n3/clinica2_tabla6.jpg" width="597" height="243"></a></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">La valoraci&oacute;n (<a href="#t7">Tabla 7</a>) del VAS, Oswestry y JOA (L) del preoperatorio respecto al mes de la cirug&iacute;a fue de 8.6/3.0, 68.0%/23.0% y 6,4%/13,1% respectivamente manteni&eacute;ndose est&aacute; mejor&iacute;a con poca desviaci&oacute;n a los 3,6 y 12 meses en 53 pacientes controlados al a&ntilde;o. En cuanto al grado de satisfacci&oacute;n con el procedimiento fue de un 94.9% (<a href="#gr1">Gr&aacute;fico 1</a>) entre completamente y muy satisfecho que coincidi&oacute; con el grado de aceptaci&oacute;n en el supuesto de repetir el tratamiento. (<a href="#gr2">Gr&aacute;fico 2</a>).</font></p>     <p align="center"><font face="Verdana" size="2"><a name="t7"><img src="/img/revistas/neuro/v22n3/clinica2_tabla7.jpg" width="592" height="149"></a></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="gr1"><img border="0" src="/img/revistas/neuro/v22n3/clinica2_grafico1.jpg" width="485" height="413"></a>    <br>Gráfico 1. <i>SRS 22. Grado de satisfacción con el procedimiento</i></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="gr2"><img border="0" src="/img/revistas/neuro/v22n3/clinica2_grafico2.jpg" width="461" height="282"></a>    <br>Gráfico 2. <i>SRS 22. Grado de aceptación del procedimiento</i></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Discusi&oacute;n</b></font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">La fijaci&oacute;n vertebral posterior es un t&eacute;cnica muy experimentada con alto &iacute;ndice de precisi&oacute;n y grado de evidencia motivo por el cual, condiciona a cirujanos de columna a prescindir de la navegaci&oacute;n. A pesar de que la navegaci&oacute;n fue introducida a principios del a&ntilde;o 2000, su uso no tom&oacute; auge hasta el 2007 coincidiendo con las modificaciones t&eacute;cnicas introducidas en el software y hardware del navegador, que han facilitado y mejorado el global del procedimiento de navegaci&oacute;n. El &iacute;ndice de precisi&oacute;n del implante con navegaci&oacute;n, en nuestra serie, ha sido del 98,4% similar a la de otros autores siendo, entre otras ventajas, superior a las t&eacute;cnicas convencionales<sup>17,11,16</sup>. La valoraci&oacute;n del implante se ha realizado mediante el control de una TC postoperatoria en m&aacute;s de 100 casos (<a href="#f5">Fig. 5</a>) y aplicando la escala de Heary cuyos resultados se compararon con la planificaci&oacute;n del trayecto de todos los casos almacenados en la memoria del navegador.</font></p>     <p align="center"><font face="Verdana" size="2"><a name="f5"><img src="/img/revistas/neuro/v22n3/clinica2_f5.jpg" width="308" height="320"></a>    <br>Figura 5. <i>Control TC postquir&uacute;rgico con grado I    <br> de Heary del implante.</i></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">Como se ha mencionado, existen diferentes opciones de navegaci&oacute;n y entre ellas la navegaci&oacute;n con Fluoro 2D-TC utilizada para este trabajo, la Fluoro ISO-C 3D y la navegaci&oacute;n por TC. Todas ellas tienen en com&uacute;n la necesidad de asociarse a un navegador y que reducen la desviaci&oacute;n del implante por debajo del 10% as&iacute; como el n&uacute;mero de reintervenciones<sup>17</sup>. Se diferencian principalmente por la adquisici&oacute;n de las im&aacute;genes ya que con el 3D como con la TC, estas son adquiridas directamente en el quir&oacute;fano y en la misma posici&oacute;n quir&uacute;rgica del paciente. Con la Fluoro 2D-TC la adquisici&oacute;n se realiza previamente a la cirug&iacute;a y en posici&oacute;n supina. Se ha mencionado que la diferente posici&oacute;n entre la adquisici&oacute;n de imagen y la quir&uacute;rgica podr&iacute;a influir en la planificaci&oacute;n de la navegaci&oacute;n<sup>25</sup> lo cual no ha sucedido con nuestro sistema ya que el software permite adaptar ambas posiciones sin presentar ninguna dificultad en la planificaci&oacute;n y navegaci&oacute;n. Entre otras diferencias t&eacute;cnicas, tanto con la Fluoro ISO C-3D como con la TC al adquirir las im&aacute;genes de forma directa permiten la posibilidad de corregir los errores del implante en el mismo acto quir&uacute;rgico si fuera necesario. A favor de la Fluoro 2D respecto a los otros sistemas<sup>25</sup> est&aacute; la posibilidad de adquirir mayor campo volum&eacute;trico con menor irradiaci&oacute;n y coste econ&oacute;mico adem&aacute;s de no precisar de una mesa quir&uacute;rgica complementaria absolutamente radio transparente.</font></p>     <p><font face="Verdana" size="2">La dificultad de la adquisici&oacute;n de buenas im&aacute;genes con el Fluoro 2D tanto a nivel cervical como dorsal dificulta una correcta fusi&oacute;n con las im&aacute;genes de TC lo que obliga a navegar solo con TC mediante la adquisici&oacute;n de m&uacute;ltiples puntos de referencia bajo cirug&iacute;a abierta y seg&uacute;n protocolo determinado por el sistema de navegaci&oacute;n. Esta dificultad en la adquisici&oacute;n de imagen, el dise&ntilde;o del instrumental y la naturaleza de la patolog&iacute;a condicion&oacute; el tipo de cirug&iacute;a realizada en nuestra serie, 42 casos a cielo abierto, 28 casos con abordajes m&iacute;nimamente invasivos y 51 casos con t&eacute;cnica percut&aacute;nea poco referida en la bibliograf&iacute;a con navegaci&oacute;n.</font></p>     <p><font face="Verdana" size="2">A nivel cervical la cirug&iacute;a se realiz&oacute; a cielo abierto con la detecci&oacute;n de m&uacute;ltiples marcas anat&oacute;micas seg&uacute;n TC. Las dificultades y el riesgo de una fijaci&oacute;n cervical pedicular posterior<sup>16,19</sup>, principalmente en el segmento C1-C2, por posibles lesiones neurol&oacute;gicas o vasculares la convierten en una t&eacute;cnica de riesgo incluso en manos expertas pero con la aplicaci&oacute;n del navegador estas complicaciones han disminuido, permitiendo una mayor seguridad del procedimiento y una menor curva de aprendizaje para los cirujanos no expertos. De los 6 casos intervenidos en C1-C2 ninguno present&oacute; complicaciones y los tornillos se alojaron seg&uacute;n la planificaci&oacute;n a excepci&oacute;n de una desviaci&oacute;n lateral interna y otra lateral externa sin repercusi&oacute;n cl&iacute;nica. En este segmento por sus caracter&iacute;sticas anat&oacute;micas y al predominar patolog&iacute;as con inestabilidad se aconseja poner el clamp de referencia para navegaci&oacute;n en C2 lo que hicimos en dos casos de la serie mientras en el resto se individualiz&oacute; cada v&eacute;rtebra no encontrando diferencias apreciables de precisi&oacute;n en la navegaci&oacute;n. Con otros sistemas de navegaci&oacute;n se coloca el clamp en el arco de fijaci&oacute;n de Mayfield para navegar. Hay autores que han descrito cirug&iacute;a guiada directa para fijaci&oacute;n transarticular C1-C2 con el Fluoro ISO C-3D<sup>33</sup>.</font></p>     <p><font face="Verdana" size="2">En la columna cervical media y baja cl&aacute;sicamente se introducen tornillos articulares pero la navegaci&oacute;n permite implantar tornillos pediculares lo que confiere una mayor estabilidad biomec&aacute;nica con menor riesgo de complicaciones<sup>19</sup>.</font></p>     <p><font face="Verdana" size="2">De los 68 tornillos de la serie solo uno present&oacute; una desviaci&oacute;n lateral interna que se manifest&oacute; con dolor radicular siendo necesario una reintervenci&oacute;n, la &uacute;nica de la serie, para extracci&oacute;n del mismo. Se ha descrito que la precisi&oacute;n del implante a nivel cervical con navegador<sup>27</sup> (Fluoro 2D-TC) frente a la sin navegador en manos expertas es del 97% y 91,7% respectivamente adem&aacute;s de reducir el tiempo quir&uacute;rgico.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">A nivel c&eacute;rvico dorsal las dificultades de una fijaci&oacute;n son bien conocidas por la escasa visualizaci&oacute;n radiol&oacute;gica debido a la interposici&oacute;n de los hombros y la disposici&oacute;n anat&oacute;mica del segmento dorsal alto. La cirug&iacute;a guiada con navegador elimina estos obst&aacute;culos al poder navegar solo con las im&aacute;genes de la TC preoperatoria permitiendo una correcta precisi&oacute;n del implante como sucedi&oacute; en los pacientes de la serie.</font></p>     <p><font face="Verdana" size="2">A nivel dorsal, las indicaciones quir&uacute;rgicas de fijaci&oacute;n m&aacute;s frecuente son las fracturas, aplastamientos y lesiones tumorales y para conseguir una fijaci&oacute;n biomec&aacute;nicamente estable y r&iacute;gida debe extenderse a dos niveles adyacentes de la v&eacute;rtebra o v&eacute;rtebras lesionadas las cuales deben estar incluidas en el estudio TC prequir&uacute;rgico. Esta cirug&iacute;a se realiza de forma abierta y se gu&iacute;a por TC utilizando la Fluoro 2D tan solo para marcar el nivel quir&uacute;rgico y en cambio con el sistema 3D y TC intra-operatorio se precisa m&aacute;s de una toma de im&aacute;genes por la limitaci&oacute;n volum&eacute;trica mencionada y por lo tanto m&aacute;s irradiaci&oacute;n.</font></p>     <p><font face="Verdana" size="2">La variabilidad de las dimensiones de los ped&iacute;culos de las v&eacute;rtebras dorsales<sup>17,26</sup> y las alteraciones en la posici&oacute;n de las v&eacute;rtebras en determinadas patolog&iacute;as como por ejemplo en la escoliosis son causa de mal posicionamiento de tornillos<sup>20,28,35,31,14</sup> (3-42%) con serias complicaciones tanto neurol&oacute;gicas como pleurales y vasculares principalmente en el segmento D4-D9, las cuales podr&iacute;an evitarse con el uso de la navegaci&oacute;n. En nuestra serie de 38 tornillos no hubo ninguna complicaci&oacute;n y todos fueron implantados seg&uacute;n se planificaron y con un tiempo quir&uacute;rgico reducido. Al igual que en el segmento cervical, por su menor incidencia, la navegaci&oacute;n aporta una confianza y seguridad a cirujanos poco expertos, dif&iacute;cil de conseguir con el m&eacute;todo cl&aacute;sico como se demuestra en estudios comparativos<sup>10</sup> entre ambas t&eacute;cnicas, aportando 85% de tornillos bien colocados sin navegaci&oacute;n precisando reintervenci&oacute;n un 7% frente al 95% con navegaci&oacute;n y sin ninguna reintervenci&oacute;n.</font></p>     <p><font face="Verdana" size="2">A nivel lumbar es donde existe mayor experiencia del uso del navegador por ser mayor la frecuencia de patolog&iacute;a principalmente de origen degenerativo. La cirug&iacute;a se realiza mediante la fusi&oacute;n de im&aacute;genes intra-operatorias adquiridas con el Fluoro 2D e im&aacute;genes del TC prequir&uacute;rgico, permitiendo realizar cirug&iacute;a guiada con t&eacute;cnica abierta (42 casos) mini-open (28 casos) o percut&aacute;nea (51 casos).</font></p>     <p><font face="Verdana" size="2">El instrumental que utilizamos para la localizaci&oacute;n y perforaci&oacute;n del ped&iacute;culo est&aacute; precalibrado y en cuanto al sistema de fijaci&oacute;n a emplear no hay limitaci&oacute;n ya que podemos calibrarlo con la matriz de calibraci&oacute;n y as&iacute; poder usar diferentes sistemas de fijaci&oacute;n siempre con tornillos canulados.</font></p>     <p><font face="Verdana" size="2">La t&eacute;cnica percut&aacute;nea la hemos realizado en pacientes con indicaci&oacute;n de fijaci&oacute;n a un solo nivel bien sea por una inestabilidad ligamentaria grado I y/o discopat&iacute;a con o sin M&oacute;dic, utilizando para ello instrumental din&aacute;mico (<a href="#f6">Fig. 6</a>) o semi-r&iacute;gido. Cuando la indicaci&oacute;n sobrepasa m&aacute;s de un segmento hemos realizado t&eacute;cnica mini-open (28 casos) con incisiones paralelas para-vertebrales seg&uacute;n t&eacute;cnica de Wiltse. En estas t&eacute;cnicas MIN el clamp se coloca en la espinosa seleccionada con una m&iacute;nima incisi&oacute;n en l&iacute;nea media.</font></p>     <p align="center"><font face="Verdana" size="2"><a name="f6"><img src="/img/revistas/neuro/v22n3/clinica2_f6.jpg" width="308" height="325"></a>    <br>Figura 6. <i>Control sagital fijaci&oacute;n percutanea din&aacute;mica.</i></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">Los resultados obtenidos en relaci&oacute;n a la precisi&oacute;n del implante han sido de 98,45% en 571 tornillos seg&uacute;n escala de Heary con una desviaci&oacute;n de 9 tornillos (1,55%). La desviaci&oacute;n de un tornillo a nivel lumbar<sup>1,18</sup> es variable y en relaci&oacute;n a la experiencia del cirujano siendo la desviaci&oacute;n del mismo la m&aacute;s referida con cifras<sup>17</sup> desde un 6,5% o de un 11,4% al 42,3% sin navegaci&oacute;n frente a 4,3% al 6,8% con Fluoro-CT o del 0,0 al 3,6% con Fluoro ISO-C 3D . La mayor&iacute;a de los tornillos desviados (85%-90%) son cl&iacute;nicamente asintom&aacute;ticos pero pueden influir en la biomec&aacute;nica de la fijaci&oacute;n o fusi&oacute;n a largo plazo.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">Hemos intentado justificar la desviaci&oacute;n de los tornillos de nuestra serie y para ello se revis&oacute; todo el procedimiento quir&uacute;rgico almacenado en el ordenador del navegador concluyendo que existen diferentes motivos para justificar dichas complicaciones y entre ellas mencionar nuestra curva de aprendizaje en los primeros 17 casos, la rotaci&oacute;n grave y luxaci&oacute;n de la v&eacute;rtebra a nivel C1 y por no navegar con el porta-tornillos calibrado en el intento de reducir el tiempo quir&uacute;rgico al confiar con la gu&iacute;a de la aguja Kirchner introducida en el ped&iacute;culo. La correcci&oacute;n de algunos de estos factores nos ha ayudado a mejorar el &iacute;ndice de precisi&oacute;n de forma progresiva.</font></p>     <p><font face="Verdana" size="2">La duraci&oacute;n del procedimiento quir&uacute;rgico con navegaci&oacute;n ha sido, entre otros, uno de los motivos de aversi&oacute;n a la t&eacute;cnica por parte de cirujanos de columna de forma err&oacute;nea ya que en estudios comparativos<sup>32</sup> de cirug&iacute;a con y sin navegaci&oacute;n el tiempo es menor con navegaci&oacute;n. En nuestra serie el tiempo que se ha utilizado para el registro y calibraci&oacute;n del instrumental ha sido de 2'49'' superada la curva de aprendizaje, lo cual no ha repercutido en el tiempo global del procedimiento sino m&aacute;s bien que lo reduce ya que facilita la b&uacute;squeda de los puntos de inserci&oacute;n y direcci&oacute;n del tornillo.</font></p>     <p><font face="Verdana" size="2">Entre las ventajas de la cirug&iacute;a guiada con navegaci&oacute;n, adem&aacute;s de su precisi&oacute;n, es la escasa irradiaci&oacute;n de todo el equipo quir&uacute;rgico y paciente. Los autores no han cuantificado la irradiaci&oacute;n con dos&iacute;metro pero s&iacute; en n&uacute;mero de disparos en proyecci&oacute;n de perfil en regi&oacute;n cervical y dorsal con una media de 1-2 respectivamente para localizar el nivel. A nivel lumbar, calibrado previamente el Kit. de fluoroscopia, se realizaron una media de 2 disparos por paciente cuando en un procedimiento sin navegaci&oacute;n y principalmente percut&aacute;neo se necesita un m&iacute;nimo de 4 o m&aacute;s disparos por tornillo para comprobar el trayecto del mismo. La exposici&oacute;n a la irradiaci&oacute;n ha sido reportada en estudio comparativo con y sin navegaci&oacute;n<sup>21</sup>, siendo pr&aacute;cticamente inapreciable la irradiaci&oacute;n con navegaci&oacute;n versus sin navegaci&oacute;n (12,4 mili-REM) del equipo quir&uacute;rgico as&iacute; como del paciente.</font></p>     <p><font face="Verdana" size="2">Tambi&eacute;n hemos podido comprobar, aunque no era el principal objetivo de este trabajo, la mejor&iacute;a cl&iacute;nica postoperatoria del paciente tanto del dolor (VAS 3.0), como del &iacute;ndice de discapacidad de Owestry (23.0%) JOA (L) 13,1 y grado de satisfacci&oacute;n con la t&eacute;cnica (94,9%), lo cual se justifica por la menor agresividad tanto de las partes blandas como &oacute;seas del procedimiento.</font></p>     <p><font face="Verdana" size="2">La indicaci&oacute;n de la navegaci&oacute;n espinal va ampli&aacute;ndose a otros campos, adem&aacute;s de la instrumentaci&oacute;n, como la realizaci&oacute;n de vertebroplastia<sup>12,30</sup>, gu&iacute;a en la artroplastia lumbar<sup>37</sup> , resecci&oacute;n de osteofitos en cirug&iacute;a por v&iacute;a anterior<sup>37</sup> y posibilidad de fijaci&oacute;n anterior de odontoides<sup>5</sup>. Los autores la han utilizado en biopsias guiadas tumoral cervical y como gu&iacute;a en cirug&iacute;a MIS para el implante intersom&aacute;tico.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Conclusiones</b></font></p>     <p><font face="Verdana" size="2">Superada la curva de aprendizaje de la t&eacute;cnica, la navegaci&oacute;n aporta al procedimiento de la instrumentaci&oacute;n vertebral posterior una mayor seguridad, una disminuci&oacute;n del riesgo de lesi&oacute;n neurol&oacute;gica, vascular y de irradiaci&oacute;n y facilita el aprendizaje para j&oacute;venes cirujanos convirtiendo la t&eacute;cnica en un acto elegante, m&iacute;nimamente invasivo e incluso de menor duraci&oacute;n que un procedimiento convencional.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Bibliografía</b></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">1. Amiot, L.P., Lang, K., Putzier M.: Comparative Results Between Conventional and Computer-Assisted Pedicle Screw Installation in the Thoracic, Lumbar, and Sacral Spine. Spine 2000; 25: 606-614.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403510&pid=S1130-1473201100030000200001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">2. Assaker, R., Cinquin, P., Cotton., Lejeune, J.P.: Image-guided endoscopic spine surgery: Part I. A feasibility study. Spine 2001; 26: 1705-1710.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403512&pid=S1130-1473201100030000200002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">3. Baldauf, J., M&uuml;ller, J.U., Fleco, S., Hinz, P., Chiriac, A., Schroeder, H.W.: The value of intraoperative three dimensional fluoroscopy in anterior decompressive surgery of the cervical spine. Zentralbl Neurochir. 2008; 69: 30-34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403514&pid=S1130-1473201100030000200003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">4. Balzer, J.R., Rose, R.D., Welch, W.C., Sclabassi, R.J.: Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompresssion and instrumentation. Neurosurgery 1988; 42: 1318-1324; discussion 1324-1325.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403516&pid=S1130-1473201100030000200004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">5. Battaglia, T.C., Tannoury, T., Crowl, A.C., Chan, D.P., Anderson, D.G.: A cadaveric study comparing standard fluoroscopy with fluoroscopy-based computer navigation for screw fixation of the odontoid. J Surg Orthop Adv. 2005; 14:175-178.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403518&pid=S1130-1473201100030000200005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">6. Bauer., Kerschbaumer., Poisel.: Cirug&iacute;a Ortop&eacute;dica, Columna. Edici&oacute;n original Georg Thieme Verlag; Marban Libros, Edici&oacute;n Espa&ntilde;ola 1998.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403520&pid=S1130-1473201100030000200006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">7. Florensa, R., Noboa, R., Mu&ntilde;oz, J., et al.: Complicaciones de la artrodesis transpedicular lumbar. Neurocirug&iacute;a 2001; 12: 216.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403522&pid=S1130-1473201100030000200007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">8. Florensa, R., Noboa, R., Mu&ntilde;oz, J., et al.: Results of C1-C2 transarticular screw fixation in a series of 20 patients. Neurocirugia 2002; 13: 429-435; discussion 436.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403524&pid=S1130-1473201100030000200008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">9. Foley, K.T., Simon, D.A., Rampersaud, Y.R.: Virtual fluoroscopy: computer-assited fluoroscopy navigation. Spine 2001; 15; 26: 347-351.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403526&pid=S1130-1473201100030000200009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">10. Fritsch, E., Duchow, J., Seil, R., Grunwald, I., Reith, W.: Accuracy of fluoroscopic navigation of pedicle screws. CT-based evaluation of bone screw placement. Orthopade. 2002; 31: 385-391. German.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403528&pid=S1130-1473201100030000200010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">11. Fuster, S., Vega, A., Barrios, G., Urdaneta, I., et al.: Fiabilidad del navegador en la colocaci&oacute;n de tornillos pediculares toracolumbares. Neurocirug&iacute;a 2010; 21: 306-311.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403530&pid=S1130-1473201100030000200011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">12. Gordon., Deen, H.G., Nottmeier, E.W.: Balloon kyphoplasty for treatment of sacral insufficiency fractures. Report of three cases. Neurosurg Focus. 2005; 18: E7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403532&pid=S1130-1473201100030000200012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">13. Heary, R.F., Bono, C.M., Black, M.: Thoracic pedicle screwspostoperative computerized tomography scanning assesment. J. Neurosurg 2004; 100 (suppl Spine): 325-331.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403534&pid=S1130-1473201100030000200013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">14. Heini, P., Scholl, E., Wyler, D., et al.: Fatal cardiac tamponade associated with posterior spinal instrumentation: a case report. Spine 1998; 23: 2226-2230.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403536&pid=S1130-1473201100030000200014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">15. Holly, L.T., Foley, K.T.: Intraoperative spinal navigation. Spine (Phila Pa 1976). 2003 ;28 (15 Suppl): S54-61.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403538&pid=S1130-1473201100030000200015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">16. Hott, J.S., Papadopoulos, S.M., Theodore, N., Dickman, C.A., Sonntag, V.K.: Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine (Phila Pa 1976) 2004; 29: 2856-2860.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403540&pid=S1130-1473201100030000200016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">17. Jaehon, M., Kim, M.D., Andrea, L., Bowers, M.D., and Kingsley, R., Chin, M.D.: Intraoperative Imaging Techniques in Spine Surgery. J. Spinal Disord.Tech. 2007: 20: 78-86.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403542&pid=S1130-1473201100030000200017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">18. Jutte, P.C., Castelein, R.M., et al.: Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 2002; 11: 594-598.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403544&pid=S1130-1473201100030000200018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">19. Kast, E., Mohr, K., Ricther, H.P., et al.: Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 2006; 15: 327-334.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403546&pid=S1130-1473201100030000200019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">20. Kim, Y., Lenke, L., Bridwell, K.: Free Hand Pedicle Screw Placement in the Thoracic Spine: It is Safe? Spine 2004; 29: 333-342.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403548&pid=S1130-1473201100030000200020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">21. Kim, C.W., Lee, Y.P., Taylor, W., Oygar, A., Kim, W.K.: Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. Spine J. 2008; 8: 584-590. Epub 2007 Feb 20.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403550&pid=S1130-1473201100030000200021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">22. Koller, H., Hitzl, W, Acosta, F.: In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III). Eur Spine J. 2009; 18:1300-1313. Epub 2009 Jul 3</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403552&pid=S1130-1473201100030000200022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">23. Kosmopoulos, V., Schizas, C.: Pedicle screw placement accuracy: meta-analysis. Spine (Phila Pa 1976). 2007; 32: E111-120</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403553&pid=S1130-1473201100030000200023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">24. Langston, T., Holly, M.D., and Kevin, T., Foley, M.D.: Intraoperative Spinal Navigation. Spine 2003; 28: 554-561.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403554&pid=S1130-1473201100030000200024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">25. Le Huec, J.C., Aunoble,S., Chalali, M., Bourghli, A.: Navigation and CT scan for navigation in spinal surgery. O-arm possibilities and limits. Argos spine News &amp; Journal. 2010;22 N<sup>o</sup>1 Focus 42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403556&pid=S1130-1473201100030000200025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">26. Lekovic, G.P., Potes, E.A., Karahalios, D.G., Hall, G.A.: Comparison of two techniques image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine. 2007; 7: 393-398.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403558&pid=S1130-1473201100030000200026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">27. Liu, Y.J., Tian, W., Liu, B., et al.: Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique. Zhonghua Wai Ke Za Zhi. 2005;  (43): 1328-1330.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403560&pid=S1130-1473201100030000200027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">28. Metz, L.N., Burch, S.: Computer-assisted surgical planning and image-guided surgical navigation in refractory adult scoliosis surgery: case report and review of the literature. Spine (Phila Pa 1976). 2008; 33: E 287-292.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403562&pid=S1130-1473201100030000200028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">29. Nolte, L., Zamorano, L., Arm, E., et al.: Image guided computer-assisited spine surgery: a pilot study on pedicle screw fixation. Stereotactic Funct Neurosurg 1996; 66: 108-117</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403564&pid=S1130-1473201100030000200029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">30. Ohnsorge, J.A., Siebert, C.H., Schkommodau, E., Mahnken, A.H., Prescher, A., Weisskopf, M.: Minimally-invasive computer-assisted fluoroscopic navigation for kyphoplasty. Z Orthop Ihre Grenzgeb. 2005;143: 195-203. German.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403565&pid=S1130-1473201100030000200030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">31. Papin, P., Arler, V., Marchesi, D., et al.: Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 1999; 8:156-159.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403567&pid=S1130-1473201100030000200031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">32. Qui&ntilde;ones-Hinojosa, A., Robert Kolen, E., Jun, P., Rosenberg, W.S., Weinstein, P.R.: Accuracy over space and time of computer-assisted fluoroscopic navigation in the lumbar spine in vivo. J Spinal Disord Tech. 2006; 19:109-113.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403569&pid=S1130-1473201100030000200032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">33. Rajasekaran, S., Vidyadhara, S., Shetty, A.P.: Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: a case report. J Spinal Disord Tech. 2007; 20: 616-619.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403571&pid=S1130-1473201100030000200033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">34. Reichle, E., Sellenschloh, K., Morlock, M., Eggers, C.: Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations. Orthopade. 2002; 31: 368-371.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403573&pid=S1130-1473201100030000200034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">35. Sarlak, A.Y., Tosun, B., Atmaca, H., Sarisoy, H.T., Bulu&ccedil;, L.: Evaluation of thoracic pedicle screw placement in adolescent idiopatic scoliosis. Eur Spine J. 2009; 18: 1892-1897</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403575&pid=S1130-1473201100030000200035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">36. Schlenzka, D., Laine, T., Lund, T.: Computer-assisted spine surgery: principles, technique, results and perspectives. Orthopade. 2000; 29: 658-669.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403576&pid=S1130-1473201100030000200036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">37. Smith, H.E., Vaccaro, A.R., Yuan, P.S., Papadopoulos, S., Sasso, R.: The use of computerized image guidance in lumbar disk arthroplasty. J Spinal Disord Tech. 2006; 19: 22-27.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403578&pid=S1130-1473201100030000200037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana" size="2">38. Woodard, E.J., Leon, S.P., Moriarty, T.M., Quinones, A., Zamani, A.A., Jolesz, F.A.: Initial experiencie with intraoperative magnetic resonace imaging in spine surgery. Spine 2001; 26: 410-417.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3403580&pid=S1130-1473201100030000200038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><a name="back"></a><a href="#top"><img src="/img/revistas/neuro/v22n3/seta.jpg" border="0"></a><b>Dirección para correspondencia:</b>    <br>Dr. Ramon Florensa.    <br>Servicio de Neurocirug&iacute;a.    <br>Hospital Germans Trias i Pujol. Badalona.    <br>E-mail: <a href="mailto:rflorensa.germanstrias@gencat.cat">rflorensa.germanstrias@gencat.cat</a></font></p>     <p><font face="Verdana" size="2">Recibido: 16-10-10.    ]]></body>
<body><![CDATA[<br>Aceptado: 26-12-10</font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amiot]]></surname>
<given-names><![CDATA[L.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Lang]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Putzier]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative Results Between Conventional and Computer-Assisted Pedicle Screw Installation in the Thoracic, Lumbar, and Sacral Spine]]></article-title>
<source><![CDATA[Spine]]></source>
<year>2000</year>
<volume>25</volume>
<page-range>606-614</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Assaker]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Cinquin]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Cotton]]></surname>
</name>
<name>
<surname><![CDATA[Lejeune]]></surname>
<given-names><![CDATA[J.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Image-guided endoscopic spine surgery: Part I. A feasibility study]]></article-title>
<source><![CDATA[Spine]]></source>
<year>2001</year>
<volume>26</volume>
<page-range>1705-1710</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baldauf]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Müller]]></surname>
<given-names><![CDATA[J.U.]]></given-names>
</name>
<name>
<surname><![CDATA[Fleco]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Hinz]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Chiriac]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Schroeder]]></surname>
<given-names><![CDATA[H.W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The value of intraoperative three dimensional fluoroscopy in anterior decompressive surgery of the cervical spine]]></article-title>
<source><![CDATA[Zentralbl Neurochir.]]></source>
<year>2008</year>
<volume>69</volume>
<page-range>30-34</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Balzer]]></surname>
<given-names><![CDATA[J.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Rose]]></surname>
<given-names><![CDATA[R.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Welch]]></surname>
<given-names><![CDATA[W.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Sclabassi]]></surname>
<given-names><![CDATA[R.J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompresssion and instrumentation]]></article-title>
<source><![CDATA[Neurosurgery]]></source>
<year>1988</year>
<volume>42</volume>
<page-range>1318-1324</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Battaglia]]></surname>
<given-names><![CDATA[T.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Tannoury]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Crowl]]></surname>
<given-names><![CDATA[A.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[D.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[D.G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A cadaveric study comparing standard fluoroscopy with fluoroscopy-based computer navigation for screw fixation of the odontoid]]></article-title>
<source><![CDATA[J Surg Orthop Adv.]]></source>
<year>2005</year>
<volume>14</volume>
<page-range>175-178</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bauer]]></surname>
</name>
<name>
<surname><![CDATA[Kerschbaumer]]></surname>
</name>
<name>
<surname><![CDATA[Poisel]]></surname>
</name>
</person-group>
<source><![CDATA[Cirugía Ortopédica, Columna]]></source>
<year>1998</year>
<publisher-name><![CDATA[Marban Libros]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Florensa]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Noboa]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Complicaciones de la artrodesis transpedicular lumbar]]></article-title>
<source><![CDATA[Neurocirugía]]></source>
<year>2001</year>
<volume>12</volume>
<page-range>216</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Florensa]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Noboa]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Results of C1-C2 transarticular screw fixation in a series of 20 patients]]></article-title>
<source><![CDATA[Neurocirugia]]></source>
<year>2002</year>
<volume>13</volume>
<page-range>429-435</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Foley]]></surname>
<given-names><![CDATA[K.T.]]></given-names>
</name>
<name>
<surname><![CDATA[Simon]]></surname>
<given-names><![CDATA[D.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Rampersaud]]></surname>
<given-names><![CDATA[Y.R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Virtual fluoroscopy: computer-assited fluoroscopy navigation]]></article-title>
<source><![CDATA[Spine]]></source>
<year>2001</year>
<volume>15</volume>
<numero>26</numero>
<issue>26</issue>
<page-range>347-351</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fritsch]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Duchow]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Seil]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Grunwald]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Reith]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy of fluoroscopic navigation of pedicle screws: CT-based evaluation of bone screw placement]]></article-title>
<source><![CDATA[Orthopade]]></source>
<year>2002</year>
<volume>31</volume>
<page-range>385-391</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fuster]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Vega]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Barrios]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Urdaneta]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Fiabilidad del navegador en la colocación de tornillos pediculares toracolumbares]]></article-title>
<source><![CDATA[Neurocirugía]]></source>
<year>2010</year>
<volume>21</volume>
<page-range>306-311</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gordon]]></surname>
</name>
<name>
<surname><![CDATA[Deen]]></surname>
<given-names><![CDATA[H.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Nottmeier]]></surname>
<given-names><![CDATA[E.W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Balloon kyphoplasty for treatment of sacral insufficiency fractures: Report of three cases]]></article-title>
<source><![CDATA[Neurosurg Focus]]></source>
<year>2005</year>
<volume>18</volume>
<page-range>E7</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heary]]></surname>
<given-names><![CDATA[R.F.]]></given-names>
</name>
<name>
<surname><![CDATA[Bono]]></surname>
<given-names><![CDATA[C.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Black]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thoracic pedicle screwspostoperative computerized tomography scanning assesment: J]]></article-title>
<source><![CDATA[Neurosurg]]></source>
<year>2004</year>
<volume>100</volume>
<page-range>325-331</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heini]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Scholl]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Wyler]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fatal cardiac tamponade associated with posterior spinal instrumentation: a case report]]></article-title>
<source><![CDATA[Spine]]></source>
<year>1998</year>
<volume>23</volume>
<page-range>2226-2230</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holly]]></surname>
<given-names><![CDATA[L.T.]]></given-names>
</name>
<name>
<surname><![CDATA[Foley]]></surname>
<given-names><![CDATA[K.T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperative spinal navigation]]></article-title>
<source><![CDATA[Spine (Phila Pa 1976)]]></source>
<year>2003</year>
<volume>28</volume>
<numero>15</numero>
<issue>15</issue>
<page-range>S54-61</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hott]]></surname>
<given-names><![CDATA[J.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Papadopoulos]]></surname>
<given-names><![CDATA[S.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Theodore]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Dickman]]></surname>
<given-names><![CDATA[C.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Sonntag]]></surname>
<given-names><![CDATA[V.K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases]]></article-title>
<source><![CDATA[Spine (Phila Pa 1976)]]></source>
<year>2004</year>
<volume>29</volume>
<page-range>2856-2860</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jaehon]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[M.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Andrea]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Bowers]]></surname>
<given-names><![CDATA[M.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Kingsley]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Chin]]></surname>
<given-names><![CDATA[M.D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperative Imaging Techniques in Spine Surgery]]></article-title>
<source><![CDATA[J. Spinal Disord.Tech.]]></source>
<year>2007</year>
<volume>20</volume>
<page-range>78-86</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jutte]]></surname>
<given-names><![CDATA[P.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Castelein]]></surname>
<given-names><![CDATA[R.M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations]]></article-title>
<source><![CDATA[Eur Spine J]]></source>
<year>2002</year>
<volume>11</volume>
<page-range>594-598</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kast]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Mohr]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Ricther]]></surname>
<given-names><![CDATA[H.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications of transpedicular screw fixation in the cervical spine]]></article-title>
<source><![CDATA[Eur Spine J]]></source>
<year>2006</year>
<volume>15</volume>
<page-range>327-334</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Lenke]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Bridwell]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Free Hand Pedicle Screw Placement in the Thoracic Spine: It is Safe?]]></article-title>
<source><![CDATA[Spine]]></source>
<year>2004</year>
<volume>29</volume>
<page-range>333-342</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[C.W.]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[Y.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Oygar]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[W.K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery]]></article-title>
<source><![CDATA[Spine J.]]></source>
<year>2008</year>
<volume>8</volume>
<page-range>584-590</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koller]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Hitzl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Acosta]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III)]]></article-title>
<source><![CDATA[Eur Spine J.]]></source>
<year>2009</year>
<volume>18</volume>
<page-range>1300-1313</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kosmopoulos]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Schizas]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pedicle screw placement accuracy: meta-analysis]]></article-title>
<source><![CDATA[Spine (Phila Pa 1976)]]></source>
<year>2007</year>
<volume>32</volume>
<page-range>E111-120</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Langston]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Holly]]></surname>
<given-names><![CDATA[M.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Kevin]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Foley]]></surname>
<given-names><![CDATA[M.D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperative Spinal Navigation]]></article-title>
<source><![CDATA[Spine]]></source>
<year>2003</year>
<volume>28</volume>
<page-range>554-561</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Le Huec]]></surname>
<given-names><![CDATA[J.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Aunoble]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Chalali]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Bourghli]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Navigation and CT scan for navigation in spinal surgery: O-arm possibilities and limits]]></article-title>
<source><![CDATA[Argos spine News & Journal]]></source>
<year>2010</year>
<volume>22</volume>
<page-range>42</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lekovic]]></surname>
<given-names><![CDATA[G.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Potes]]></surname>
<given-names><![CDATA[E.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Karahalios]]></surname>
<given-names><![CDATA[D.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Hall]]></surname>
<given-names><![CDATA[G.A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of two techniques image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws]]></article-title>
<source><![CDATA[J Neurosurg Spine]]></source>
<year>2007</year>
<volume>7</volume>
<page-range>393-398</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Y.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Tian]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique]]></article-title>
<source><![CDATA[Zhonghua Wai Ke Za Zhi.]]></source>
<year>2005</year>
<volume>43</volume>
<page-range>1328-1330</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Metz]]></surname>
<given-names><![CDATA[L.N.]]></given-names>
</name>
<name>
<surname><![CDATA[Burch]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computer-assisted surgical planning and image-guided surgical navigation in refractory adult scoliosis surgery: case report and review of the literature]]></article-title>
<source><![CDATA[Spine (Phila Pa 1976)]]></source>
<year>2008</year>
<volume>33</volume>
<page-range>E 287-292</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nolte]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Zamorano]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Arm]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Image guided computer-assisited spine surgery: a pilot study on pedicle screw fixation]]></article-title>
<source><![CDATA[Stereotactic Funct Neurosurg]]></source>
<year>1996</year>
<volume>66</volume>
<page-range>108-117</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ohnsorge]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Siebert]]></surname>
<given-names><![CDATA[C.H.]]></given-names>
</name>
<name>
<surname><![CDATA[Schkommodau]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Mahnken]]></surname>
<given-names><![CDATA[A.H.]]></given-names>
</name>
<name>
<surname><![CDATA[Prescher]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Weisskopf]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Minimally-invasive computer-assisted fluoroscopic navigation for kyphoplasty]]></article-title>
<source><![CDATA[Z Orthop Ihre Grenzgeb.]]></source>
<year>2005</year>
<volume>143</volume>
<page-range>195-203</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Papin]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Arler]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Marchesi]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis]]></article-title>
<source><![CDATA[Eur Spine J]]></source>
<year>1999</year>
<volume>8</volume>
<page-range>156-159</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quiñones-Hinojosa]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Robert Kolen]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Jun]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenberg]]></surname>
<given-names><![CDATA[W.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Weinstein]]></surname>
<given-names><![CDATA[P.R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy over space and time of computer-assisted fluoroscopic navigation in the lumbar spine in vivo]]></article-title>
<source><![CDATA[J Spinal Disord Tech.]]></source>
<year>2006</year>
<volume>19</volume>
<page-range>109-113</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rajasekaran]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Vidyadhara]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Shetty]]></surname>
<given-names><![CDATA[A.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: a case report]]></article-title>
<source><![CDATA[J Spinal Disord Tech.]]></source>
<year>2007</year>
<volume>20</volume>
<page-range>616-619</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reichle]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Sellenschloh]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Morlock]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Eggers]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Placement of pedicle screws using different navigation systems: A laboratory trial with 12 spinal preparations]]></article-title>
<source><![CDATA[Orthopade]]></source>
<year>2002</year>
<volume>31</volume>
<page-range>368-371</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sarlak]]></surname>
<given-names><![CDATA[A.Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Tosun]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Atmaca]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Sarisoy]]></surname>
<given-names><![CDATA[H.T.]]></given-names>
</name>
<name>
<surname><![CDATA[Buluç]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of thoracic pedicle screw placement in adolescent idiopatic scoliosis]]></article-title>
<source><![CDATA[Eur Spine J.]]></source>
<year>2009</year>
<volume>18</volume>
<page-range>1892-1897</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schlenzka]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Laine]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Lund]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computer-assisted spine surgery: principles, technique, results and perspectives]]></article-title>
<source><![CDATA[Orthopade]]></source>
<year>2000</year>
<volume>29</volume>
<page-range>658-669</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[H.E.]]></given-names>
</name>
<name>
<surname><![CDATA[Vaccaro]]></surname>
<given-names><![CDATA[A.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Yuan]]></surname>
<given-names><![CDATA[P.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Papadopoulos]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Sasso]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of computerized image guidance in lumbar disk arthroplasty]]></article-title>
<source><![CDATA[J Spinal Disord Tech.]]></source>
<year>2006</year>
<volume>19</volume>
<page-range>22-27</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Woodard]]></surname>
<given-names><![CDATA[E.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Leon]]></surname>
<given-names><![CDATA[S.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Moriarty]]></surname>
<given-names><![CDATA[T.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Quinones]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Zamani]]></surname>
<given-names><![CDATA[A.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Jolesz]]></surname>
<given-names><![CDATA[F.A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Initial experiencie with intraoperative magnetic resonace imaging in spine surgery]]></article-title>
<source><![CDATA[Spine]]></source>
<year>2001</year>
<volume>26</volume>
<page-range>410-417</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>