<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1134-8046</journal-id>
<journal-title><![CDATA[Revista de la Sociedad Española del Dolor]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Soc. Esp. Dolor]]></abbrev-journal-title>
<issn>1134-8046</issn>
<publisher>
<publisher-name><![CDATA[Inspira Network Group, S.L ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1134-80462016000200008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Nuevo simulador híbrido cadavérico/sintético para la enseñanza de técnicas intervencionistas para tratamiento del dolor refractario]]></article-title>
<article-title xml:lang="en"><![CDATA[New hybrid simulator to teach pain procedures for refractory pain management]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[J.C.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
<xref ref-type="aff" rid="A02"/>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Centro de Atención Integral del Dolor Buenos Aires- CAIDBA  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,World Institute of Pain Latin American Section ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Clínica San Camilo Sección Medicina del Dolor ]]></institution>
<addr-line><![CDATA[Buenos Aires ]]></addr-line>
<country>Argentina</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2016</year>
</pub-date>
<volume>23</volume>
<numero>2</numero>
<fpage>105</fpage>
<lpage>114</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S1134-80462016000200008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S1134-80462016000200008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S1134-80462016000200008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se presenta un nuevo simulador para el entrenamiento y evaluación de técnicas intervencionistas bajo visión fluoroscópica en medicina del dolor que permite realizar los procedimientos más utilizados a nivel de cabeza y cuello, tronco, región lumbosacra y pelvis. En el trabajo se desarrolló una inclusión de material óseo cadavérico en material sintético versión no transparente color piel y transparente para entrenamiento en bloqueos bajo visión ecográfica y fluoroscópica combinados. El Nuevo Simulador Híbrido se basó en la inclusión artesanal de material óseo cadavérico dentro de un tejido de material sintético emulando, con elevado realismo, el modelo humano. En la experiencia de los educandos que realizaron los talleres durante el año 2014 expresaron alta satisfacción comparando a pacientes reales, cadáveres frescos y simuladores sintéticos. Este desarrollo permite, como características principales: a) repetir cada procedimiento las veces necesarias para que cada educando alcance un estándar mínimo exigible y disminuya el número y tipo de errores posibles propios de cada técnica; b) entrenar adecuadamente para los procesos de certificación; c) facilitar evaluar la eficacia de entrenar con estos modelos frente al entrenamiento en pacientes reales u otras formas de entrenamiento (simuladores o cadáveres frescos); d) mejorar la accesibilidad por su bajo costo evitando la complejidad de la preservación de tejidos, y e) permitir, en opinión del autor, reducir la curva de aprendizaje en un medio seguro para paciente, educando, docente y el sistema de salud y universitario.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[This paper introduces a new simulator to be used in the training and evaluation of interventional techniques under fluoroscopic visualization in pain medicine, apt for repeating the most broadly used procedures in the head and neck, trunk, lumbosacral region and pelvis. This simulator is built using cadaveric bones in synthetic transparent material for training in nerve block procedures under combined ultrasonic and fluoroscopic guidance. The "New Hybrid Simulator" comprises the use of cadaveric bones surrounded by synthetic material resembling human models in a highly realistic manner. The trainees that attended the workshops during 2014 expressed a high degree of satisfaction when comparing this model to practicing on real patients, fresh cadavers and synthetic simulators. The salient features of this development are: repeating the procedures as many times as necessary for each trainee to meet the minimum requirements and reduce the number and type of potential errors in each technique; conducting appropriate training for certification purposes; facilitating the evaluation of efficacy of training using these models as compared to training on real patients or other modalities (simulators or fresh cadavers); improving accessibility given its low cost, thus avoiding the complexity involved in the preservation of tissues and finally, in the author's opinion reducing the learning curve in a safe setting for patients, trainees, trainers and for the healthcare and university systems at large.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Simulación en medicina del dolor]]></kwd>
<kwd lng="es"><![CDATA[simulación híbrida en medicina del dolor]]></kwd>
<kwd lng="es"><![CDATA[simulación y certificación]]></kwd>
<kwd lng="es"><![CDATA[simulación y seguridad]]></kwd>
<kwd lng="en"><![CDATA[Simulators in pain medicine]]></kwd>
<kwd lng="en"><![CDATA[hybrid simulators in pain medicine]]></kwd>
<kwd lng="en"><![CDATA[simulation and certification]]></kwd>
<kwd lng="en"><![CDATA[simulation and safety]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <a name="top"></a>    <p><font face="Verdana" size="2"><b>ART&Iacute;CULO ESPECIAL</b></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="4"><b>Nuevo simulador h&iacute;brido cadav&eacute;rico/sint&eacute;tico para la ense&ntilde;anza de t&eacute;cnicas intervencionistas para tratamiento del dolor refractario</b></font></p>     <p><font face="Verdana" size="4"><b>New hybrid simulator to teach pain procedures for refractory pain management</b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>J.C. Flores</b></font></p>     <p><font face="Verdana" size="2">Director CAIDBA. EPP Award. Buenos Aires, Argentina. Chairman Latin American Section World Institute of Pain. Director Workshop "T&eacute;cnicas Intervencionistas para Tratamiento del Dolor Refractario". Jefe de Secci&oacute;n Medicina del Dolor. Cl&iacute;nica San Camilo. Buenos Aires, Argentina</font></p>     <p><font face="Verdana" size="2"><a href="#bajo">Direcci&oacute;n para correspondencia</a></font></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p> <hr size="1">     <p><font face="Verdana" size="2"><b>RESUMEN</b></font></p>     <p><font face="Verdana" size="2">Se presenta un nuevo simulador para el entrenamiento y evaluaci&oacute;n de t&eacute;cnicas intervencionistas bajo visi&oacute;n fluorosc&oacute;pica en medicina del dolor que permite realizar los procedimientos m&aacute;s utilizados a nivel de cabeza y cuello, tronco, regi&oacute;n lumbosacra y pelvis. En el trabajo se desarroll&oacute; una inclusi&oacute;n de material &oacute;seo cadav&eacute;rico en material sint&eacute;tico versi&oacute;n no transparente color piel y transparente para entrenamiento en bloqueos bajo visi&oacute;n ecogr&aacute;fica y fluorosc&oacute;pica combinados.    <br>El Nuevo Simulador H&iacute;brido se bas&oacute; en la inclusi&oacute;n artesanal de material &oacute;seo cadav&eacute;rico dentro de un tejido de material sint&eacute;tico emulando, con elevado realismo, el modelo humano. En la experiencia de los educandos que realizaron los talleres durante el a&ntilde;o 2014 expresaron alta satisfacci&oacute;n comparando a pacientes reales, cad&aacute;veres frescos y simuladores sint&eacute;ticos. Este desarrollo permite, como caracter&iacute;sticas principales: a) repetir cada procedimiento las veces necesarias para que cada educando alcance un est&aacute;ndar m&iacute;nimo exigible y disminuya el n&uacute;mero y tipo de errores posibles propios de cada t&eacute;cnica; b) entrenar adecuadamente para los procesos de certificaci&oacute;n; c) facilitar evaluar la eficacia de entrenar con estos modelos frente al entrenamiento en pacientes reales u otras formas de entrenamiento (simuladores o cad&aacute;veres frescos); d) mejorar la accesibilidad por su bajo costo evitando la complejidad de la preservaci&oacute;n de tejidos, y e) permitir, en opini&oacute;n del autor, reducir la curva de aprendizaje en un medio seguro para paciente, educando, docente y el sistema de salud y universitario.</font></p>     <p><font face="Verdana" size="2"><b>Palabras clave:</b> Simulaci&oacute;n en medicina del dolor, simulaci&oacute;n h&iacute;brida en medicina del dolor, simulaci&oacute;n y certificaci&oacute;n, simulaci&oacute;n y seguridad.</font></p> <hr size="1">     <p><font face="Verdana" size="2"><b>ABSTRACT</b></font></p>     <p><font face="Verdana" size="2">This paper introduces a new simulator to be used in the training and evaluation of interventional techniques under fluoroscopic visualization in pain medicine, apt for repeating the most broadly used procedures in the head and neck, trunk, lumbosacral region and pelvis. This simulator is built using cadaveric bones in synthetic transparent material for training in nerve block procedures under combined ultrasonic and fluoroscopic guidance.    <br>The "New Hybrid Simulator" comprises the use of cadaveric bones surrounded by synthetic material resembling human models in a highly realistic manner. The trainees that attended the workshops during 2014 expressed a high degree of satisfaction when comparing this model to practicing on real patients, fresh cadavers and synthetic simulators. The salient features of this development are: repeating the procedures as many times as necessary for each trainee to meet the minimum requirements and reduce the number and type of potential errors in each technique; conducting appropriate training for certification purposes; facilitating the evaluation of efficacy of training using these models as compared to training on real patients or other modalities (simulators or fresh cadavers); improving accessibility given its low cost, thus avoiding the complexity involved in the preservation of tissues and finally, in the author's opinion reducing the learning curve in a safe setting for patients, trainees, trainers and for the healthcare and university systems at large.</font></p>     <p><font face="Verdana" size="2"><b>Key words:</b> Simulators in pain medicine, hybrid simulators in pain medicine, simulation and certification, simulation and safety.</font></p> <hr size="1">     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p><font face="Verdana" size="2">En la formaci&oacute;n actual de M&eacute;dicos Especialistas en Medicina del Dolor los educadores actuales intentan adecuar los procesos de capacitaci&oacute;n y entrenamiento para responder a los desaf&iacute;os que representa el creciente n&uacute;mero y complejidad de las t&eacute;cnicas intervencionistas. La dificultad es mayor debido al tiempo limitado de formaci&oacute;n, escasa disponibilidad de pacientes por cada educando y la necesidad de evaluaci&oacute;n para certificar a nuevos profesionales que deben asistir a pacientes reales que dan su consentimiento (1,2).</font></p>     <p><font face="Verdana" size="2">Las universidades, la industria tecnol&oacute;gica y las sociedades cient&iacute;ficas han encarado el problema de la educaci&oacute;n m&eacute;dica utilizando como puente para zanjar esta brecha educacional la incorporaci&oacute;n de la simulaci&oacute;n como un recurso que intenta reemplazar varios prototipos de pacientes y escenarios de entrenamiento sin exponer pacientes progresivamente reticentes y, a su vez, permitiendo las repeticiones necesarias y certificaciones en escenarios muchas veces imposibles de reproducir en la vida real (1-4).</font></p>     <p><font face="Verdana" size="2"><i>De este modo, el entrenamiento con simuladores est&aacute; tratando de mitigar la brecha se&ntilde;alada entre la formaci&oacute;n te&oacute;rica y el entrenamiento pr&aacute;ctico.</i></font></p>     <p><font face="Verdana" size="2">Como la educaci&oacute;n con simuladores, cad&aacute;veres frescos, <i>training devices</i>, preparados anat&oacute;micos y diversos modelos tratando de ocupar el lugar del paciente real est&aacute;n alcanzando importante prevalencia, se hace necesario determinar cu&aacute;nto impactan los resultados de la atenci&oacute;n m&eacute;dica y verificar, en estudios de evidencia, la validez de las t&eacute;cnicas educativas escasamente evaluadas hasta el presente.</font></p>     <p><font face="Verdana" size="2">Dentro de las &aacute;reas donde el entrenamiento se ha demostrado deficitario es posible, con simuladores, entrenar espec&iacute;ficamente para corregir ese d&eacute;ficit y buscar un resultado final m&aacute;s est&aacute;ndar, o sea, con menor variabilidad. Un ejemplo valioso en este sentido ha sido el manejo de situaciones cr&iacute;ticas inesperadas que requieren resucitaci&oacute;n cardiopulmonar, o eventos cr&iacute;ticos en anestesiolog&iacute;a, algoritmos de v&iacute;a a&eacute;rea dif&iacute;cil, manejo de escenarios de trauma, shock hemorr&aacute;gico, hipertermia maligna, entre muchos otros que pueden o no presentarse de manera aleatoria durante el periodo de tiempo de una residencia, pero que en el simulador se pueden programar y repetir las veces necesarias hasta que el alumno alcance los resultados m&iacute;nimos exigidos (5-9).</font></p>     <p><font face="Verdana" size="2">Levine y cols., en b&uacute;squeda de evidencia, realizaron una investigaci&oacute;n y confirmaron que el entrenamiento con simuladores para realizar la cirug&iacute;a laparosc&oacute;pica mejoraba la performance de los residentes (3). Estos test demostraron que el entrenamiento con simulaci&oacute;n mejoraba el conocimiento m&eacute;dico, el confort durante los procedimientos y en la performance cuando se realiza reevaluaci&oacute;n en escenarios simulados. De este modo, al disponer de simuladores se podr&iacute;a realizar entrenamiento a demanda compensando el posible d&eacute;ficit de paciente en patolog&iacute;as menos prevalentes durante el periodo de formaci&oacute;n. Seg&uacute;n Gordon JA, Pawlowski J, del programa de simulaci&oacute;n m&eacute;dica del Harvard Medical School de Massachusetts, todos sus estudiantes pueden tener, desde los escenarios simulados, el caso apropiado para ense&ntilde;anza, o <i>good teaching case</i>, como prototipo para entrenar en la situaci&oacute;n m&eacute;dica por compleja que sea. Este punto singular pone &eacute;nfasis en que no alcanza para entrenar en forma efectiva disponer de un paciente real, un cad&aacute;ver fresco o un simulador realista, sino que el mismo <i>debe ser apropiado para lo que se pretende transmitir o entrenar al educando</i> (5).</font></p>     <p><font face="Verdana" size="2">Muchas veces el entrenamiento en seres vivos tiene limitaciones, adem&aacute;s de la dificultad de la repetici&oacute;n del procedimiento y que el paciente pueda otorgar la licencia a que lo realice s&oacute;lo un aprendiz. Algunos pacientes no son modelos adecuados y son reales, pero no permiten el entrenamiento realista porque no son un caso t&iacute;pico o promedio y no permiten ganar experiencia por ser una parte de la muestra que se encuentra en los extremos de la campana de GAUS y lo puede y debe realizar el instructor experimentado.</font></p>     <p><font face="Verdana" size="2">Las cualidades del principal recurso did&aacute;ctico que es el paciente o alguno de sus sustitutos (cad&aacute;ver fresco o simulador) impacta la eficiencia de la curva de aprendizaje para alcanzar un nivel efectivo de entrenamiento.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">El estudio de Friedman analiza la influencia de la ense&ntilde;anza con Simuladores de Anestesia Epidural con modelos de diferente fidelidad sobre la extensi&oacute;n de la curva de aprendizaje (10).</font></p>     <p><font face="Verdana" size="2">La curva de aprendizaje es una etapa inevitable del entrenamiento en que el educando realiza repeticiones y perfecciona la t&eacute;cnica hasta identificar, prevenir y minimizar los posibles errores propios de cada t&eacute;cnica. Esto transcurre en un periodo de tiempo que es afectado por m&uacute;ltiples factores, como la prevalencia y la complejidad de la patolog&iacute;a, el tiempo de formaci&oacute;n de la residencia, el n&uacute;mero de residentes que compiten por el caso en cuesti&oacute;n, fortaleza y madurez emocional del residente, el riesgo del paciente que es expuesto y, adem&aacute;s, el n&uacute;mero y capacidad de los instructores para proporcionar el grado apropiado de supervisi&oacute;n.</font></p>     <p><font face="Verdana" size="2">Sin duda, cuando el modelo simulado de entrenamiento es realista y reproduce suficientes elementos del escenario real y puede aportar los casos necesarios para todos los residentes, requiere menos supervisi&oacute;n al no exponer los pacientes, al disminuir el miedo a cometer errores y permitiendo investigar alternativas considerando que no se expone a un paciente, como se&ntilde;ala Friedrich en <i>JAMA</i>, y se da lugar a un entrenamiento libre de riesgos y con mayor creatividad o riesgo "0", como se&ntilde;ala Duncan en <i>Chest</i>. Finalmente, permite completar el entrenamiento en todas las entidades nosol&oacute;gicas al margen de la suficiencia de pacientes (11,12).</font></p>     <p><font face="Verdana" size="2">Fried dijo que la tecnolog&iacute;a de simulaci&oacute;n en cirug&iacute;a laparosc&oacute;pica se ha desarrollado en respuesta a la necesidad de ense&ntilde;ar habilidades quir&uacute;rgicas fundamentales en un medio seguro. Esta afirmaci&oacute;n puede hacerse extensiva al manejo de muchas situaciones complejas que atraviesan toda la medicina (13-21).</font></p>     <p><font face="Verdana" size="2">La mayor&iacute;a de los simuladores que se han desarrollado han sido tecnolog&iacute;as costosas y algunos investigadores han desarrollado "alternativas caseras" (22-25). El estudio de Hamstra, publicado en <i>Reg Anesth Pain Med</i>, ha demostrado que con los modelos de baja fidelidad se han logrado buenos scores de performance y cheklist similares a los modelos de alta fidelidad (26-28).</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Herramientas did&aacute;cticas principales para ense&ntilde;anza de t&eacute;cnicas intervencionistas</b></font></p>     <p><font face="Verdana" size="2">El entrenamiento en muchas t&eacute;cnicas intervencionista sufre limitaciones, al igual que en otras &aacute;reas de la especializaci&oacute;n m&eacute;dica, por lo dif&iacute;cil y riesgoso de colocar por primera vez agujas pr&oacute;ximas a ramas del trig&eacute;mino rodeadas de estructuras nobles del SNC, el PHS pr&oacute;ximo al carrefour a&oacute;rtico, el espacio epidural cervical en estrecha relaci&oacute;n con la m&eacute;dula espinal, los nervios espl&aacute;cnicos y sus adyacencias y, as&iacute;, muchas otras estructuras que generan riesgos potencialmente significativos. A su vez, <i>entrenar en el &aacute;mbito de la exigencia acad&eacute;mica universitaria</i> no debe, y no ser&iacute;a aconsejable, que dejase de significar ensayar o reproducir una pr&aacute;ctica un n&uacute;mero suficiente de veces para que la certificaci&oacute;n o t&iacute;tulo otorgado sirva como garant&iacute;a, o un grado de prueba que el profesional es indiscutiblemente id&oacute;neo.</font></p>     <p><font face="Verdana" size="2">En los &uacute;ltimos 30 a&ntilde;os ha alcanzado reconocimiento el uso de cad&aacute;veres frescos para la ense&ntilde;anza de muchas t&eacute;cnicas con el <i>realismo de utilizar material humano</i> ante las dificultades obvias del uso de modelos vivos o de pacientes.</font></p>     <p><font face="Verdana" size="2">Con la colaboraci&oacute;n de maestros como Gabor Racz, Nilesh Patel y Octavio Calvillo, el autor dirigi&oacute; el VIII Curso Internacional de la Fundaci&oacute;n Dolor en la Ciudad en Buenos Aires, este workshop fue pionero en Latinoam&eacute;rica hace 15&nbsp;a&ntilde;os para la ense&ntilde;anza de t&eacute;cnicas intervencionistas con cad&aacute;veres frescos bajo visi&oacute;n fluorosc&oacute;pica, y luego pudo repetirlos numerosas veces en todos estos a&ntilde;os. Ellos y muchos otros l&iacute;deres han impulsado la misma metodolog&iacute;a con cad&aacute;veres frescos en numerosos pa&iacute;ses. Es innegable que esta modalidad educativa ha cumplido y sigue teniendo un rol importante para talleres de refresco de t&eacute;cnicas. Tal es as&iacute; que, en centros internacionalmente prestigiosos, se organizan ex&aacute;menes para certificaci&oacute;n con cad&aacute;veres frescos alcanzando una suerte de est&aacute;ndar aunque, como se mencion&oacute;, no ha sido sometida la validez de tal metodolog&iacute;a a estudios de evidencia "durante el periodo de formaci&oacute;n del experto" hasta el momento.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">El trabajo con cad&aacute;veres frescos tiene la ventaja de utilizar el modelo humano y permite repetir los procedimientos y revisar cada una de las etapas, como en los simuladores, con la ventaja del absoluto realismo que implica ser material humano. Por otra parte, tiene entre sus limitaciones que requiere la disponibilidad de suficientes cad&aacute;veres frescos para entrenar a todos los profesionales necesarios, adem&aacute;s de infraestructura costosa para preservaci&oacute;n de los mismos, gente especializada en los procesos de preparaci&oacute;n y mantenimiento y extremar cuidados de historia cl&iacute;nica que eviten que efluentes cadav&eacute;ricos insuficientemente estudiados en laboratorio medicinal puedan exponer a los estudiantes, a los profesionales o al personal asistente con poca experiencia a potenciales contagios de enfermedades no estudiadas. El entrenamiento se realiza en el cad&aacute;ver fresco que se encuentra disponible y no es posible modificar el material; puede ser en muchos casos de buena calidad y un ejemplo apropiado para entrenamiento y, a su vez, puede presentar en tantos otros limitaciones por no ser un caso que permita extrapolar a la mayor&iacute;a de los casos por tener variantes anat&oacute;micas espec&iacute;ficas. Una limitaci&oacute;n adicional puede surgir al preservar la fascie o cara por su posible reconocimiento que puede derivar en cuestionamientos human&iacute;sticos y/o religiosos relacionados a la preservaci&oacute;n de la identidad.</font></p>     <p><font face="Verdana" size="2">Por otra parte, a pesar de la bibliograf&iacute;a aportada en esta publicaci&oacute;n (29-38), en opini&oacute;n del autor los simuladores disponibles en la actualidad para la pr&aacute;ctica de bloqueos no han aportado el realismo necesario para permitir o imaginar una extrapolaci&oacute;n al escenario real y no ha logrado ser reconocida como una formaci&oacute;n realista equivalente a los cad&aacute;veres frescos. Han sido valiosos para alcanzar habilidades y aprendizaje en la pr&aacute;ctica de t&eacute;cnicas, y tambi&eacute;n en el manejo de materiales "en principiantes", pero no en reconocer blancos anat&oacute;micos reales por ser los modelos existentes en el mercado demasiado esquem&aacute;ticos y adem&aacute;s alejados de provocar sensaciones, como reconocer el manejo de tejidos en un paciente real.</font></p>     <p><font face="Verdana" size="2">La diferencia principal no se basa en las sensaciones al punzar los tejidos porque, en la mayor&iacute;a de los casos, el material cadav&eacute;rico puede, asimismo, distar de ser realista por estar excesivamente envejecido, traumatizado, deshidratado, a veces semicongelado, y puede corresponder a variable grupo etario pero, sin embargo, conserva su utilidad porque <i>su similitud al humano se confirma solamente a trav&eacute;s de la identificaci&oacute;n de su parte &oacute;sea, siendo que los bloqueos se realizan bajo visi&oacute;n fluorosc&oacute;pica.</i> En consecuencia, la diferencia mayor entre los modelos vivos, preparados cadav&eacute;ricos y los simuladores no se encuentra en el tejido no &oacute;seo, y que &eacute;ste tiene, aun en condiciones normales, notables variaciones.</font></p>     <p><font face="Verdana" size="2">Si la t&eacute;cnica involucra la visualizaci&oacute;n o identificaci&oacute;n de partes blandas y no se observan m&uacute;sculos, vasos, nervios, fascias o tendones, el modelo no ser&aacute; &uacute;til si no cuenta con dichos elementos. En caso de que la t&eacute;cnica involucre visualizaci&oacute;n de partes &oacute;seas como corresponde a los procedimientos de tratamiento del dolor bajo fluoroscopia, la visualizaci&oacute;n de piezas anat&oacute;micas &oacute;seas id&eacute;nticas a las humanas, o que sean partes &oacute;seas propiamente humanas, es indispensable y suficiente para que el entrenamiento tenga validez y sea efectivamente realista (37-49).</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Evoluci&oacute;n de la medicina del dolor y la disponibilidad de recursos did&aacute;cticos</b></font></p>     <p><font face="Verdana" size="2">La medici&oacute;n de la eficacia de la educaci&oacute;n m&eacute;dica debe considerar los nuevos recursos que se suceden en los &uacute;ltimos a&ntilde;os incorporando modernas tecnolog&iacute;as que, a trav&eacute;s de la simulaci&oacute;n, como se mencion&oacute; previamente, buscan atenuar el gap entre la teor&iacute;a y la pr&aacute;ctica (50-53).</font></p>     <p><font face="Verdana" size="2">La historia contempor&aacute;nea de la Medicina del Dolor ha evolucionado con los cambios de la Anestesiolog&iacute;a, y se pueden considerar como principales referenciasen la primera mitad del siglo xx la cl&iacute;nica del dolor de John Lundy, las <i>ense&ntilde;anzas de John Bonica de bloqueos diagn&oacute;sticos y terap&eacute;uticos en la residencia de anestesiolog&iacute;a y, en las &uacute;ltimas d&eacute;cadas, los talleres en cad&aacute;veres frescos de Gabor Racz y Prithvi Raj, entre otros.</i> Desde los primeros bloqueos con el desarrollo de la anestesia regional hasta nuestros d&iacute;as, estos colegas y muchos de sus numerosos disc&iacute;pulos desarrollaron m&aacute;s de 140 t&eacute;cnicas intervencionistas para el tratamiento del dolor (54-63).</font></p>     <p><font face="Verdana" size="2">Los consejos de expertos indicaron que para autorizar su ejecuci&oacute;n (certificaci&oacute;n, especializaci&oacute;n o experticia) era preciso entrenarse por un espacio de tiempo en un determinado contexto que se reconoci&oacute; como residencia o felow, que defin&iacute;a el &aacute;mbito y sus actividades donde el m&eacute;dico ejerc&iacute;a cerca de sus maestros (supervisi&oacute;n) para realizar sus primeros pasos, cuidar su adquisici&oacute;n de conocimientos y madurar su destreza t&eacute;cnica hasta realizar, bajo su propia responsabilidad, de un modo seguro y habiendo sido evaluado durante dicho proceso e incluso poder llegar a supervisar el aprendizaje de otros hasta alcanzar finalmente el reconocimiento de ser calificado como par, un profesional. <i>&Eacute;ste ha sido el paradigma de todas las residencias m&eacute;dicas.</i></font></p>     <p><font face="Verdana" size="2">Durante ese proceso y bajo supervisi&oacute;n, el educando deb&iacute;a copiar, imitar, emular al maestro y, en ese escenario, tambi&eacute;n copiado o simulado de las situaciones posibles a afrontar, intentando hacer las tareas como su maestro. El material humano que permite el entrenamiento durante la residencia m&eacute;dica representa la s&iacute;ntesis del conjunto de pacientes que deber&aacute; saber manejar desde entonces.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2"><i>El conflicto surge en que la "disponibilidad de recursos did&aacute;cticos equivalentes a los pacientes reales" en los programas de formaci&oacute;n a nivel global para que los m&eacute;dicos expertos lleguen suficientemente entrenados a un examen de certificaci&oacute;n ha sido, hasta nuestros d&iacute;as, extraordinariamente limitada.</i></font></p>     <p><font face="Verdana" size="2">Al margen de las caracter&iacute;sticas del programa de entrenamiento, el tiempo de formaci&oacute;n, el n&uacute;mero de t&eacute;cnicas, la pluralidad de patolog&iacute;as que maneja el centro en cuesti&oacute;n y el n&uacute;mero de residentes y de supervisores, sin duda uno de los principales cuellos de botella es el n&uacute;mero de pacientes con las patolog&iacute;as a tratar que pueden ser abordados por todos los m&eacute;dicos aspirantes a ser certificados. <i>Esta aparente controversia respecto a la "limitada disponibilidad de pacientes" se ha generado por la diversidad de profesionales de la salud que anuncian asistir pacientes con dolor y, de ese modo, diversifican y escamotean ante los ojos del paciente y los sistemas de formaci&oacute;n la existencia de una atenci&oacute;n especializada donde los m&eacute;dicos aprenden t&eacute;cnicas para tratar "dolores refractarios".</i></font></p>     <p><font face="Verdana" size="2">¿Existen suficientes pacientes con patolog&iacute;as espec&iacute;ficas para preparar nuevos especialistas considerando el grosero d&eacute;ficit de RRHH en esta &aacute;rea para formar nuevos expertos y para asistir la poblaci&oacute;n en el contexto actual? El estudio de Harald Breivik demostr&oacute; cu&aacute;n alarmante es la respuesta a esta pregunta: el problema es gigante, ya que s&oacute;lo el 2 % de la poblaci&oacute;n Europea en 2006 era asistida por profesionales especializados; este estudio nos pone a la vista que las universidades en todo el mundo deber&iacute;an organizar la capacitaci&oacute;n de los m&eacute;dicos en general y el entrenamiento de especialistas que luchen contra este flagelo con una metodolog&iacute;a evolucionada como la que ha sido id&oacute;nea en las otras especializadas m&eacute;dicas o desarrollar nuevas metodolog&iacute;as, considerando la evoluci&oacute;n de las tecnolog&iacute;as educativas (64-66).</font></p>     <p><font face="Verdana" size="2">Denton Cooley, Christian Barnard, Rene Favaloro, Menno Sluijter, John Bonica y Gabor Racz se entrenaron en pacientes reales y en salas de preparados anat&oacute;micos. Estos fueron suficientes y justificaron sobradamente que aquellos pacientes les cedieran sus cuerpos para transformarse en l&iacute;deres mundiales.</font></p>     <p><font face="Verdana" size="2"><i>Claramente, el costo y el riesgo de la exposici&oacute;n de la vida o la salud humanas durante el proceso de entrenamiento de m&eacute;dicos que dejan de ser inexpertos para transformarse en profesionales es el tema de an&aacute;lisis al considerar no s&oacute;lo formas de entrenamiento, sino tambi&eacute;n formas de evaluaci&oacute;n que permitan extrapolar sus resultados para habilitar a los expertos certificados para que, despu&eacute;s de superado dicho proceso, puedan anunciarse como expertos en determinada t&eacute;cnica cuando nunca han asistido a un paciente real</i>, m&aacute;xime en el escenario actual de baja tolerancia y creciente litigiosidad.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Desarrollo del nuevo simulador h&iacute;brido cadav&eacute;rico/sint&eacute;tico</b></font></p>     <p><font face="Verdana" size="2">La propuesta del presente simulador h&iacute;brido desde el Centro M&eacute;dico CAIDBA se bas&oacute; en los conceptos precedentes, considerando las dificultades expuestas de los cad&aacute;veres frescos y las limitaciones de los simuladores sint&eacute;ticos existentes. Se entendi&oacute; que un nuevo simulador no deb&iacute;a limitarse a una nueva copia del esqueleto como otra maqueta o prototipo. De este modo, se realiz&oacute; la inclusi&oacute;n de un esqueleto &oacute;seo cadav&eacute;rico humano dentro de material sint&eacute;tico (siliconas, caucho, poliuretano y otros) como tejido no &oacute;seo. A esta asociaci&oacute;n de materiales le cabe la denominaci&oacute;n de h&iacute;brido, combinando partes cadav&eacute;ricas y partes sint&eacute;ticas (<a href="#f1">Figura 1</a>).</font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f1"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura1.jpg"></a></font></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="Verdana" size="2">El autor considera que el desarrollo de este modelo de simulador h&iacute;brido podr&iacute;a facilitar el acceso al entrenamiento en t&eacute;cnicas intervencionistas y disminuir la complejidad y costos de preservaci&oacute;n de cad&aacute;veres frescos o la compra de simuladores sint&eacute;ticos costosos. Asimismo, permitir&iacute;a organizar el programa de entrenamiento sin l&iacute;mites de tiempo porque el preparado no se descompone ni emite olores, y no necesita regresar a una nevera para su preservaci&oacute;n.</font></p>     <p><font face="Verdana" size="2">La imitaci&oacute;n, emulaci&oacute;n, admiraci&oacute;n y repetici&oacute;n copiando al maestro durante el entrenamiento asistiendo pacientes son los t&eacute;rminos que hist&oacute;ricamente han regido la relaci&oacute;n del alumno y el maestro, y la simulaci&oacute;n del paciente debe permitir realizar el entrenamiento de un profesional trabajando sobre esos mismos par&aacute;metros.</font></p>     <p><font face="Verdana" size="2">El entrenamiento hospitalario con pacientes reales tiene, entre otras limitaciones, que el paciente permite ser punzado una sola vez por un solo educando y, para que ello ocurra, &eacute;ste debe generar cierta confianza en su instructor para que le pueda delegar tal acci&oacute;n y, a su vez, implica tomar riesgos reales que un paciente debe aceptar o rechazar y que en las situaciones complejas es el supervisor quien debe realizar el acto para no exponer m&aacute;s all&aacute; de lo razonable al paciente.</font></p>     <p><font face="Verdana" size="2">El uso de simuladores permite repetir el proceso numerosas veces, modificar partes o etapas del mismo, discutir c&oacute;mo se est&aacute; haciendo una pr&aacute;ctica y evaluar los riesgos de cada paso y volver a intentarlos. Se puede ensayar en casos t&iacute;picos y adem&aacute;s en distintas patolog&iacute;as preparadas en el modelo y no s&oacute;lo en un modelo est&aacute;ndar.</font></p>     <p><font face="Verdana" size="2">El simulador h&iacute;brido utilizado para entrenamiento en t&eacute;cnicas intervencionistas bajo visi&oacute;n fluorosc&oacute;pica fue ensayado frente a material cadav&eacute;rico fresco y al simulador Kip Kohrman, que es un modelo completamente sint&eacute;tico. Se realizaron 2 Workshop de 8 colegas cada uno para ense&ntilde;ar t&eacute;cnicas intervencionistas a m&eacute;dicos expertos en medicina del dolor aspirantes a someterse al examen para FIPP. Las pr&aacute;cticas ensayadas son las 24 pr&aacute;cticas m&aacute;s utilizadas divididas en grupos de cabeza y cuello, t&oacute;rax, lumbar y pelvis. El resultado de la aplicaci&oacute;n del nuevo simulador gener&oacute; alto nivel de satisfacci&oacute;n y preparaci&oacute;n adecuada para quienes aplicaron para la certificaci&oacute;n ante el tribunal del WIP, y alta aceptaci&oacute;n para quienes hab&iacute;an realizado previamente talleres con cad&aacute;veres frescos y simuladores sint&eacute;ticos. El consenso comparativo con los educandos que evaluaron el presente modelo, todos expertos en t&eacute;cnicas intervencionistas, se presenta en la <a target="_blank" href="/img/revistas/dolor/v23n2/08_articulo_especial_tabla1.jpg">tabla I</a>.</font></p>     <p><font face="Verdana" size="2">La experiencia con el simulador h&iacute;brido fue de alta satisfacci&oacute;n en la experiencia pr&aacute;ctica y de elevado realismo en la calidad de las im&aacute;genes que gu&iacute;an los procedimientos (<a href="#f2">Figuras 2 a 5</a>).</font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f2"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura2.jpg"></a></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="center"><font face="Verdana" size="2"><a name="f3"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura3.jpg"></a></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f4"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura4.jpg"></a></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f5"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura5.jpg"></a></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">Con el nuevo simulador en un modelo de silicona trasparente a la ultrasonograf&iacute;a se pudo ensayar t&eacute;cnicas h&iacute;bridas, como bloqueos facetarios o transforaminales, haciendo el acercamiento bajo visi&oacute;n ecogr&aacute;fica y dejando 1 o 2 disparos de fluoroscopia para confirmar la posici&oacute;n final de la aguja y as&iacute; disminuyendo significativamente la exposici&oacute;n a la radiaci&oacute;n ionizante. As&iacute;, la educaci&oacute;n con simuladores puede ajustar el entrenamiento para la realizaci&oacute;n de procedimientos m&aacute;s seguros (<a href="#f6">Figuras 6 a 8</a>).</font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f6"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura6.jpg"></a></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="center"><font face="Verdana" size="2"><a name="f7"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura7.jpg"></a></font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f8"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura8.jpg"></a></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2">En la opini&oacute;n del autor, con simuladores en el entrenamiento de t&eacute;cnicas intervencionistas se podr&iacute;a aportar un contexto m&aacute;s seguro para los procesos de evaluaci&oacute;n y certificaci&oacute;n similar a su aplicaci&oacute;n en algunas residencias de Anestesiolog&iacute;a (67,68).</font></p>     <p><font face="Verdana" size="2">Con la introducci&oacute;n del nuevo simulador h&iacute;brido se confirma que se puede preparar material sint&eacute;tico que hace las veces de tejidos humanos y hace posible modificar su resistencia, dureza y las caracter&iacute;sticas necesarias de los componentes no &oacute;seos del modelo hasta provocar una emulaci&oacute;n de elevado realismo.</font></p>     <p><font face="Verdana" size="2">Tambi&eacute;n se puede disponer en la actualidad de tecnolog&iacute;as scanner 3D e impresi&oacute;n 3D para el desarrollo de modelos copiados de distintas estructuras org&aacute;nicas como cr&aacute;neos, columnas, pelvis, costillas, esc&aacute;pulas, rodillas, adem&aacute;s de distintos tejidos permeables o impermeables al ultrasonido, trasparentes o con colores s&iacute;mil humanos. Ahora estamos desarrollando modelos sint&eacute;tico/sint&eacute;tico para realizar bloqueos en simuladores con copias exactas de componentes de la columna enferma con distintas entidades (escoliosis, fractura aplastamiento, listesis, esponsiloartrosis) en que es necesario desarrollar una pericia especial (<a href="#f9">Figura 9</a>).</font></p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="2"><a name="f9"><img src="/img/revistas/dolor/v23n2/08_articulo_especial_figura9.jpg"></a></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2"><b>Conclusi&oacute;n</b></font></p>     <p><font face="Verdana" size="2">Con la inclusi&oacute;n &oacute;sea cadav&eacute;rica en cuerpo sint&eacute;tico se logr&oacute; concretar una experiencia realista utilizando tambi&eacute;n el "modelo humano" y llevar a cabo nuestras primeras pr&aacute;cticas en el Nuevo Simulador H&iacute;brido cadav&eacute;rico/sint&eacute;tico para ense&ntilde;anza de bloqueos y los tratamientos intervencionistas m&aacute;s sofisticados del dolor bajo fluoroscopia y bajo ultrasonograf&iacute;a.</font></p>     <p><font face="Verdana" size="2">Finalmente, la introducci&oacute;n de la simulaci&oacute;n h&iacute;brida (cad&aacute;ver/sint&eacute;tica) para la ense&ntilde;anza de t&eacute;cnicas intervencionista para tratamiento del dolor refractario en la propuesta del autor promueve como probable mejora a confirmar en otros estudios:</font></p>     <p><font face="Verdana" size="2">- Facilitar el acceso a un modelo alternativo que permita un entrenamiento realista.</font></p>     <p><font face="Verdana" size="2">- Repetir cada procedimiento las veces necesarias para que cada educando alcance un est&aacute;ndar m&iacute;nimo exigible para superar los procesos de evaluaci&oacute;n.</font></p>     <p><font face="Verdana" size="2">- Reducir a un nivel aceptable las complicaciones inherentes a errores t&eacute;cnicos.</font></p>     <p><font face="Verdana" size="2">- Permitir a trav&eacute;s de su realismo ensayar o investigar y comparar t&eacute;cnicas previas a su aplicaci&oacute;n en el hombre.</font></p>     <p><font face="Verdana" size="2">- Facilitar el desarrollo de modelos con alteraciones y patolog&iacute;as &oacute;seas simuladas como escoliosis o listesis.</font></p>     <p><font face="Verdana" size="2">- Investigar la eficacia de entrenar con estos modelos f&aacute;cilmente repetibles frente al entrenamiento en pacientes reales.</font></p>     <p><font face="Verdana" size="2">- Disponer de material de entrenamiento en todas las universidades que no sufran limitaciones de n&uacute;mero o de variedad de entidades patol&oacute;gicas.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">- Mejorar la accesibilidad por su bajo costo, evitando la complejidad de la preservaci&oacute;n de tejidos.</font></p>     <p><font face="Verdana" size="2">- Evitar dificultades por cuestiones human&iacute;sticas, legales o religiosas al utilizar espec&iacute;menes humanos completos cadav&eacute;ricos por cuestiones de identidad.</font></p>     <p><font face="Verdana" size="2">- Evitar la barrera obligada del consentimiento informado en "pacientes reales" en el entorno hospitalario que s&oacute;lo admite una punci&oacute;n absolutamente perfecta o efectiva por paciente.</font></p>     <p><font face="Verdana" size="2">- Entrenar en la pr&aacute;ctica de t&eacute;cnicas h&iacute;bridas, combinando ecograf&iacute;a y fluoroscopia para reducir la exposici&oacute;n a la radiaci&oacute;n ionizante. As&iacute;, el simulador puede contribuir para que el entrenamiento puede hacer m&aacute;s segura la educaci&oacute;n y la asistencia.</font></p>     <p><font face="Verdana" size="2">- Y, finalmente permitir, en opini&oacute;n del autor, reducir la curva de aprendizaje en un medio seguro para paciente, educando, docente y el sistema de formaci&oacute;n.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Bibliograf&iacute;a</b></font></p>     <!-- ref --><p><font face="Verdana" size="2">1. Paradise LA, Raj PP. Competency and certification of pain physicians. Pain Pract 2004;4(3):235-44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930727&pid=S1134-8046201600020000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">2. Raj P. Educaci&oacute;n y certificaci&oacute;n. En: Flores JC (ed). Medicina del dolor. Perspectiva internacional. Barcelona: Elsevier; 2015. p. 49-55.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930729&pid=S1134-8046201600020000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">3. Okuda Y, Bryson EO, DeMaria S Jr, Jacobson L, Quinones J, Shen B, Levine AI. The utility of simulation in medical education: What is the evidence? Mt Sinai J Med 2009;76(4):330-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930731&pid=S1134-8046201600020000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">4. Blum RH, Boulet JR, Cooper JB, Muret-Wagstaff SL; Harvard Assessment of Anesthesia Resident Performance Research Group. Simulation-based assessment to identify critical gaps in safe anesthesia resident performance. Anesthesiology 2014;120(1):129-41.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930733&pid=S1134-8046201600020000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">5. Gordon JA, Pawlowski J. Education on-demand: The development of a simulator-based medical education service. Acad Med 2002;77(7):751-2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930735&pid=S1134-8046201600020000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">6. Cheng A, Brown LL, Duff JP, Davidson J, Overly F, Tofil NM, et al. Improving cardiopulmonary resuscitation with a CPR feedback device and refresher simulations (CPR CARES Study): A randomized clinical trial. JAMA Pediatr 2015;169(2):137-44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930737&pid=S1134-8046201600020000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">7. Holzman RS, Cooper JB, Gaba DM, Philip JH, Small SD, Feinstein D. Anesthesia crisis resource management: Real-life simulation training in operating room crises. J Clin Anesth 1995;7(8):675-87.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930739&pid=S1134-8046201600020000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">8. Cooper JB, Taqueti VR. A brief history of the development of mannequin simulators for clinical education and training. Postgrad Med J; 2008;84(997):563-70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930741&pid=S1134-8046201600020000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">9. Gaba DM. The future vision of simulation in health care. Quad Saf Health Care; 2004;13 Suppl 1:i2-10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930743&pid=S1134-8046201600020000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">10. Friedman Z, Siddiqui N, Katznelson R, Devito I, Bould MD, Naik V. Clinical impact of epidural anesthesia simulation on short- and long-term learning curve: High- versus low-fidelity model training. Reg Anesth Pain Med 2009;34(3):229-32.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930745&pid=S1134-8046201600020000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">11. Friedrich MJ. Practice makes perfect: Risk-free medical training with patient simulators. JAMA 2002;288(22):2808, 2811-2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930747&pid=S1134-8046201600020000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">12. Duncan DR, Morgenthaler TI, Ryu JH, Daniels CE. Reducing iatrogenic risk in thoracentesis: Establishing best practice via experiential training in a zero-risk environment. Chest 2009;135(5):1315-20.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930749&pid=S1134-8046201600020000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">13. Issenberg SB1, McGaghie WC, Petrusa ER, Lee Gordon D, Scalese RJ. Features and uses of high-fidelity medical simulations that lead to effective learning: A BEME systematic review. Med Teach 2005;27(1):10-28.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930751&pid=S1134-8046201600020000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">14. Fried GM. Lessons from the surgical experience with simulators: Incorporation into training and utilization in determining competency. Gastrointest Endosc Clin N Am; 2006;16(3):425-34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930753&pid=S1134-8046201600020000800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">15. Ti LK1, Tan GM, Khoo SG, Chen FG. The impact of experiential learning on NUS medical students: Our experience with task trainers and human-patient simulation. Ann Acad Med Singapor 2006;35(9):619-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930755&pid=S1134-8046201600020000800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">16. Epstein RM. Assessment in medical education. N Engl J Med 2007;356(4):387-96.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930757&pid=S1134-8046201600020000800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">17. Cooper JB, Singer SJ, Hayes J, Sales M, Vogt JW, Raemer D, et al. Design and evaluation of simulation scenarios for a program introducing patient safety, teamwork, safety leadership, and simulation to healthcare leaders and managers. Simul Healthc 2011;6(4):231-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930759&pid=S1134-8046201600020000800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">18. Price JW, Price JR, Pratt DD, Collins JB, McDonald J. High-fidelity simulation in anesthesiology training: A survey of Canadian anesthesiology residents' simulator experience. Can J Anaesth 2010;57(2):134-42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930761&pid=S1134-8046201600020000800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">19. Cook DA, Hatala R, Brydges R, Zendejas B, Szostek JH, Wang AT, et al. Technology-enhanced simulation for health professions education: A systematic review and meta-analysis. JAMA 2011;306(9):978-88.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930763&pid=S1134-8046201600020000800019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">20. Ilgen JS, Sherbino J, Cook DA. Technology-enhanced simulation in emergency medicine: A systematic review and meta-analysis. Acad Emerg Med 2013;20(2):117-27.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930765&pid=S1134-8046201600020000800020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">21. van Dijk N, Hooft L, Wieringa-de Waard M. What are the barriers to residents' practicing evidence-based medicine? A systematic review. Acad Med 2010;85(7):1163-70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930767&pid=S1134-8046201600020000800021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">22. Bellingham GA, Peng PW. A low-cost ultrasound phantom of the lumbosacral spine. Reg Anesth Pain Med 2010;35(3):290-3.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930769&pid=S1134-8046201600020000800022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">23. Lerman IR, Souzdalnitski D, Narouze S. A low-cost, durable, combined ultrasound and fluoroscopic phantom for cervical transforaminal injections. Reg Anesth Pain Med 2012;37(3):344-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930771&pid=S1134-8046201600020000800023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">24. Inoue S, Fujiwara A, Watanabe K, Hashizume K, Furuya H. Inexpensive phantom for fluoroscopy guided nerve block training. Pain Med 2008;9(7):863-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930773&pid=S1134-8046201600020000800024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">25. Cook DA, Beckman TJ. High-value, cost-conscious medical education. JAMA Pediatr 2015;169(2):109-11.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930775&pid=S1134-8046201600020000800025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">26. Gonzalez-Cota A, Chiravuri S, Stansfield RB, Brummett CM, Hamstra SJ. The effect of bench model fidelity on fluoroscopy-guided transforaminal epidural injection training: A randomized control study. Reg Anesth Pain Med; 38(2):155-60.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930777&pid=S1134-8046201600020000800026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">27. Maschuw K, Hassan I, Bartsch DK. Surgical training using simulator. Virtual reality. Chirurg 2010;81(1):19-24.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930779&pid=S1134-8046201600020000800027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">28. Nicksa GA, Anderson C, Fidler R, Stewart L. Innovative approach using interprofessional simulation to educate surgical residents in technical and nontechnical skills in high-risk clinical scenarios. JAMA Surg 2015; 150(3):201-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930781&pid=S1134-8046201600020000800028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">29. Coleman EA. Extending simulation learning experiences to patients with chronic health conditions. JAMA 2014;311(3):243-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930783&pid=S1134-8046201600020000800029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">30. Gillan SN, Saleh GM. Ophthalmic surgical simulation: A new era. JAMA Ophthalmol 2013;131(12):1623-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930785&pid=S1134-8046201600020000800030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">31. Zhang N, Sumer BD. Transoral robotic surgery: Simulation-based standardized training. JAMA Otolaryngol Head Neck Sur. 2013;139(11):1111-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930787&pid=S1134-8046201600020000800031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">32. Kneebone RL. Practice, rehearsal, and performance: An approach for simulation-based surgical and procedure training. JAMA 2009; 302(20):2190-2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930789&pid=S1134-8046201600020000800032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">33. Voelker R. Medical simulation gets real. JAMA 2009;302(12):1336-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930791&pid=S1134-8046201600020000800033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">34. Botden SM, Torab F, Buzink SN, Jakimowicz JJ. The importance of haptic feedback in laparoscopic suturing training and the additive value of virtual reality simulation. Surg Endosc 2008;22(5):1214-22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930793&pid=S1134-8046201600020000800034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">35. Vaughan N, Dubey VN, Wee MY, Isaacs R. Towards a realistic in vitro experience of epidural Tuohy needle insertion. Proc Inst Mech Eng H 2013;227(7):767-77.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930795&pid=S1134-8046201600020000800035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">36. De Lorenzo D, Koseki Y, De Momi E, Chinzei K, Okamura AM. Coaxial needle insertion assistant with enhanced force feedback. IEEE Trans Biomed Eng 2013;60(2):379-89.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930797&pid=S1134-8046201600020000800036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">37. Magill JC, Byl MF, Hinds MF, Agassounon W, Pratt SD, Hess PE. A novel actuator for simulation of epidural anesthesia and other needle insertion procedures. Simul Healthc 2010;5(3):179-84.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930799&pid=S1134-8046201600020000800037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">38. Lim YJ, Valdivia P, Chang C, Tardella N. MR fluid haptic system for regional anesthesia training simulation system. Stud Health Technol Inform 2008;132:248-53.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930801&pid=S1134-8046201600020000800038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">39. Hu J, Lim YJ, Tardella N, Chang C, Warren L. Localized virtual patient model for regional anesthesia simulation training system. Stud Health Technol Inform 2007;125:185-90.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930803&pid=S1134-8046201600020000800039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">40. Hamstra SJ, Dubrowski A, Backstein D. Teaching technical skills to surgical residents: A survey of empirical research. Clin Orthop Relat Res 2006;449:108-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930805&pid=S1134-8046201600020000800040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">41. Mudumbai SC, Fanning R, Howard SK, Davies MF, Gaba DM. Use of medical simulation to explore equipment failures and human-machine interactions in anesthesia machine pipeline supply crossover. Anesth Analg 2010;110(5):1292-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930807&pid=S1134-8046201600020000800041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">42. Fanning RM, Gaba DM. The role of debriefing in simulation-based learning. Simul Healthc 2007;2(2):115-25.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930809&pid=S1134-8046201600020000800042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">43. Zhu Y, Magee D, Ratnalingam R, Kessel D. A training system for ultrasound-guided needle insertion procedures. Med Image Comput Comput Assist Interv 2007;10(Pt 1):566-74.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930811&pid=S1134-8046201600020000800043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">44. Hocking G, Hebard S, Mitchell CH. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia. Reg Anesth Pain Med 2011;36(2):162-70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930813&pid=S1134-8046201600020000800044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">45. Chin KJ1, Perlas A, Chan VW, Brull R. Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions. Reg Anesth Pain Med 2008;33(6):532-44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930815&pid=S1134-8046201600020000800045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">46. Rosenberg AD, Popovic J, Albert DB, Altman RA, Marshall MH, Sommer RM, et al. Three partial-task simulators for teaching ultrasound-guided regional anesthesia. Reg Anesth Pain Med 2012;37(1):106-10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930817&pid=S1134-8046201600020000800046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">47. Freschi C, Parrini S, Dinelli N, Ferrari M, Ferrari V. Hybrid simulation using mixed reality for interventional ultrasound imaging training. Int J Comput Assist Radiol Surg 2015; 10(7):1109-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930819&pid=S1134-8046201600020000800047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">48. Feifer A, Al-Ammari A, Kovac E, Delisle J, Carrier S, Anidjar M. Randomized controlled trial of virtual reality and hybrid simulation for robotic surgical training. BJU Int 2011;108(10):1652-6; discussion 1657.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930821&pid=S1134-8046201600020000800048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">49. Tavakol M, Mohagheghi MA, Dennick R. Assessing the skills of surgical residents using simulation. J Surg Educ 2008;65(2):77-83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930823&pid=S1134-8046201600020000800049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">50. Epstein RM. Assessment in medical education. N Engl J Med 2007;356(4):387-96.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930825&pid=S1134-8046201600020000800050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">51. Uppal V, Kearns RJ, McGrady EM. Evaluation of M43B Lumbar puncture simulator-II as a training tool for identification of the epidural space and lumbar puncture. Anaesthesia 2011;66(6):493-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930827&pid=S1134-8046201600020000800051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">52. Capogna G, Stirparo S, Caniggia S. Evaluation of a new training device to simulate the epidural and subarachnoid spaces for neuraxial anesthesia techniques. Minerva Anestesiol 2013;79(4):385-90.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930829&pid=S1134-8046201600020000800052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">53. Weller JM. Simulation in undergraduate medical education: Bridging the gap between theory and practice. Med Educ 2004;38(1):32-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930831&pid=S1134-8046201600020000800053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">54. Lundy JS. The present opportunities for medical men in anaesthesia. Can Med Assoc J 1937;37(6):552-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930833&pid=S1134-8046201600020000800054&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">55. Lundy JS. The use of local anesthetics. JAMA 1936;107(18):1464-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930835&pid=S1134-8046201600020000800055&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">56. Lundy JS. Diagnostic and therapeutic nerve block in general practice. Northwest Med 1951;50(8):577-82.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930837&pid=S1134-8046201600020000800056&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">57. Lundy JS. Cancer Pain. J Lancet 1964;84:15-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930839&pid=S1134-8046201600020000800057&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">58. Kopp SL, Horlocker TT, Bacon DR. The contribution of John Lundy in the development of peripheral and neuraxial nerve blocks at the Mayo Clinic: 1925-1940. M.A. Regional Anesthesia &amp; Pain Medicine 2002;27(3):322-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930841&pid=S1134-8046201600020000800058&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">59. Bonica JJ. Teaching residents diagnostic and therapeutic nerve blocks. Curr Res Anesth Analg 1955;34(4):202-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930843&pid=S1134-8046201600020000800059&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">60. Bonica JJ. Management of intractable pain with analgesic blocks. J Am Med Assoc 1952;150(16):1581-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930845&pid=S1134-8046201600020000800060&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">61. Bonica JJ. Nerve blocks as an aid in the diagnosis and therapy of disease. Northwest Med 1950;49(9):593-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930847&pid=S1134-8046201600020000800061&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">62. Manchikanti L, Boswell MV, Raj PP, Racz GB. Evolution of interventional pain management. Pain Physician 2003;6(4):485-94.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930849&pid=S1134-8046201600020000800062&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">63. Manchikanti L, Heavner JE, Racz GB, Mekhail N, Schultz DM, Hansen HC, et al. Methods for evidence synthesis in interventional pain management. Pain Physician 2003;6(1):89-111.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930851&pid=S1134-8046201600020000800063&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">64. Flores JC. Cap&iacute;tulo 1. En: Medicina del Dolor. Perspectiva Internacional. Flores JC (ed). Barcelona: Ed Elsevier; 2015. p. 2-20.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930853&pid=S1134-8046201600020000800064&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">65. Breivik H, Collett B, Ventafridda V, Cohen R, Gallacher D. Survey of chronic pain in Europe: Prevalence, impact on daily life, and treatment. Eur J Pain 2006;10(4):287-333.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930855&pid=S1134-8046201600020000800065&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">66. Gouvitsos F, Vallet B, Scherpereel P. Anesthesia simulators: benefits and limits of experience gained at several European university hospitals. Ann Fr Anesth Reanim 1999;18(7):787-95.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930857&pid=S1134-8046201600020000800066&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">67. Schwid HA, Rooke GA, Carline J, Steadman RH, Murray WB, Olympio M, et al. Evaluation of anesthesia residents using mannequin-based simulation: A multiinstitutional study. Anesthesiology 2002;97(6):1434-44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930859&pid=S1134-8046201600020000800067&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">68. Murray DJ1, Boulet JR, Avidan M, Kras JF, Henrichs B, Woodhouse J, et al. Performance of residents and anesthesiologists in a simulation-based skill assessment. Anesthesiology 2007;107(5):705-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4930861&pid=S1134-8046201600020000800068&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><a href="#top"><img border="0" src="/img/revistas/dolor/v23n2/seta.gif" width="15" height="17"></a><a name="bajo"></a><b>Direcci&oacute;n para correspondencia:</b>    <br>Juan Carlos Flores    <br><a href="mailto:jcflores.caidba@gmail.com">jcflores.caidba@gmail.com</a></font></p>     <p><font face="Verdana" size="2">Recibido: 2-4-2015.    <br>Aceptado: 4-6-2015.</font></p>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Paradise]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Raj]]></surname>
<given-names><![CDATA[PP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Competency and certification of pain physicians]]></article-title>
<source><![CDATA[Pain Pract]]></source>
<year>2004</year>
<volume>4</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>235-44</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Raj]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Educación y certificación]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<source><![CDATA[Medicina del dolor: Perspectiva internacional]]></source>
<year>2015</year>
<page-range>49-55</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Okuda]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Bryson]]></surname>
<given-names><![CDATA[EO]]></given-names>
</name>
<name>
<surname><![CDATA[DeMaria]]></surname>
<given-names><![CDATA[S Jr]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobson]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Quinones]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Levine]]></surname>
<given-names><![CDATA[AI.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The utility of simulation in medical education: What is the evidence?]]></article-title>
<source><![CDATA[Mt Sinai J Med]]></source>
<year>2009</year>
<volume>76</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>330-43</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Blum]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Boulet]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Muret-Wagstaff]]></surname>
<given-names><![CDATA[SL]]></given-names>
</name>
</person-group>
<collab>Harvard Assessment of Anesthesia Resident Performance Research Group</collab>
<article-title xml:lang="en"><![CDATA[Simulation-based assessment to identify critical gaps in safe anesthesia resident performance]]></article-title>
<source><![CDATA[Anesthesiology]]></source>
<year>2014</year>
<volume>120</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>129-41</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gordon]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Pawlowski]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Education on-demand: The development of a simulator-based medical education service]]></article-title>
<source><![CDATA[Acad Med]]></source>
<year>2002</year>
<volume>77</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>751-2</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[LL]]></given-names>
</name>
<name>
<surname><![CDATA[Duff]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Davidson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Overly]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Tofil]]></surname>
<given-names><![CDATA[NM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improving cardiopulmonary resuscitation with a CPR feedback device and refresher simulations (CPR CARES Study): A randomized clinical trial]]></article-title>
<source><![CDATA[JAMA Pediatr]]></source>
<year>2015</year>
<volume>169</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>137-44</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holzman]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Gaba]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Philip]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Small]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Feinstein]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anesthesia crisis resource management: Real-life simulation training in operating room crises]]></article-title>
<source><![CDATA[J Clin Anesth]]></source>
<year>1995</year>
<volume>7</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>675-87</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Taqueti]]></surname>
<given-names><![CDATA[VR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A brief history of the development of mannequin simulators for clinical education and training]]></article-title>
<source><![CDATA[Postgrad Med J]]></source>
<year>2008</year>
<volume>84</volume>
<numero>997</numero>
<issue>997</issue>
<page-range>563-70</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gaba]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The future vision of simulation in health care]]></article-title>
<source><![CDATA[Quad Saf Health Care;]]></source>
<year>2004</year>
<volume>13</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>i2-10</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Friedman]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Siddiqui]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Katznelson]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Devito]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Bould]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
<name>
<surname><![CDATA[Naik]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical impact of epidural anesthesia simulation on short- and long-term learning curve: High- versus low-fidelity model training]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year>2009</year>
<volume>34</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>229-32</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Friedrich]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Practice makes perfect: Risk-free medical training with patient simulators]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2002</year>
<volume>288</volume>
<numero>22</numero>
<issue>22</issue>
<page-range>2808</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duncan]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
<name>
<surname><![CDATA[Morgenthaler]]></surname>
<given-names><![CDATA[TI]]></given-names>
</name>
<name>
<surname><![CDATA[Ryu]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Daniels]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reducing iatrogenic risk in thoracentesis: Establishing best practice via experiential training in a zero-risk environment]]></article-title>
<source><![CDATA[Chest]]></source>
<year>2009</year>
<volume>135</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1315-20</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Issenberg]]></surname>
<given-names><![CDATA[SB1]]></given-names>
</name>
<name>
<surname><![CDATA[McGaghie]]></surname>
<given-names><![CDATA[WC]]></given-names>
</name>
<name>
<surname><![CDATA[Petrusa]]></surname>
<given-names><![CDATA[ER]]></given-names>
</name>
<name>
<surname><![CDATA[Lee Gordon]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Scalese]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Features and uses of high-fidelity medical simulations that lead to effective learning: A BEME systematic review]]></article-title>
<source><![CDATA[Med Teach]]></source>
<year>2005</year>
<volume>27</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>10-28</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fried]]></surname>
<given-names><![CDATA[GM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lessons from the surgical experience with simulators: Incorporation into training and utilization in determining competency]]></article-title>
<source><![CDATA[Gastrointest Endosc Clin N Am;]]></source>
<year>2006</year>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>425-34</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ti]]></surname>
<given-names><![CDATA[LK1]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[GM]]></given-names>
</name>
<name>
<surname><![CDATA[Khoo]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[FG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The impact of experiential learning on NUS medical students: Our experience with task trainers and human-patient simulation]]></article-title>
<source><![CDATA[Ann Acad Med Singapor]]></source>
<year>2006</year>
<volume>35</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>619-23</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Epstein]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment in medical education]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2007</year>
<volume>356</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>387-96</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Singer]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hayes]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sales]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Vogt]]></surname>
<given-names><![CDATA[JW]]></given-names>
</name>
<name>
<surname><![CDATA[Raemer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design and evaluation of simulation scenarios for a program introducing patient safety, teamwork, safety leadership, and simulation to healthcare leaders and managers]]></article-title>
<source><![CDATA[Simul Healthc]]></source>
<year>2011</year>
<volume>6</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>231-8</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Price]]></surname>
<given-names><![CDATA[JW]]></given-names>
</name>
<name>
<surname><![CDATA[Price]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Pratt]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
<name>
<surname><![CDATA[Collins]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[McDonald]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High-fidelity simulation in anesthesiology training: A survey of Canadian anesthesiology residents' simulator experience]]></article-title>
<source><![CDATA[Can J Anaesth]]></source>
<year>2010</year>
<volume>57</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>134-42</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Hatala]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Brydges]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Zendejas]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Szostek]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[AT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Technology-enhanced simulation for health professions education: A systematic review and meta-analysis]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2011</year>
<volume>306</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>978-88</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ilgen]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Sherbino]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Technology-enhanced simulation in emergency medicine: A systematic review and meta-analysis]]></article-title>
<source><![CDATA[Acad Emerg Med]]></source>
<year>2013</year>
<volume>20</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>117-27</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Dijk]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hooft]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Wieringa-de Waard]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[What are the barriers to residents' practicing evidence-based medicine?: A systematic review]]></article-title>
<source><![CDATA[Acad Med]]></source>
<year>2010</year>
<volume>85</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1163-70</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bellingham]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A low-cost ultrasound phantom of the lumbosacral spine]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year>2010</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>290-3</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lerman]]></surname>
<given-names><![CDATA[IR]]></given-names>
</name>
<name>
<surname><![CDATA[Souzdalnitski]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Narouze]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A low-cost, durable, combined ultrasound and fluoroscopic phantom for cervical transforaminal injections]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year>2012</year>
<volume>37</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>344-8</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Inoue]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fujiwara]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hashizume]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Furuya]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inexpensive phantom for fluoroscopy guided nerve block training]]></article-title>
<source><![CDATA[Pain Med]]></source>
<year>2008</year>
<volume>9</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>863-5</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Beckman]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High-value, cost-conscious medical education]]></article-title>
<source><![CDATA[JAMA Pediatr]]></source>
<year>2015</year>
<volume>169</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>109-11</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gonzalez-Cota]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Chiravuri]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Stansfield]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Brummett]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Hamstra]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of bench model fidelity on fluoroscopy-guided transforaminal epidural injection training: A randomized control study]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year></year>
<volume>38</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>155-60</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maschuw]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hassan]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Bartsch]]></surname>
<given-names><![CDATA[DK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Surgical training using simulator: Virtual reality]]></article-title>
<source><![CDATA[Chirurg]]></source>
<year>2010</year>
<volume>81</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>19-24</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nicksa]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Fidler]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Stewart]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Innovative approach using interprofessional simulation to educate surgical residents in technical and nontechnical skills in high-risk clinical scenarios]]></article-title>
<source><![CDATA[JAMA Surg]]></source>
<year>2015</year>
<volume>150</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>201-7</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Coleman]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Extending simulation learning experiences to patients with chronic health conditions]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2014</year>
<volume>311</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>243-4</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gillan]]></surname>
<given-names><![CDATA[SN]]></given-names>
</name>
<name>
<surname><![CDATA[Saleh]]></surname>
<given-names><![CDATA[GM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ophthalmic surgical simulation: A new era]]></article-title>
<source><![CDATA[JAMA Ophthalmol]]></source>
<year>2013</year>
<volume>131</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1623-4</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Sumer]]></surname>
<given-names><![CDATA[BD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Transoral robotic surgery: Simulation-based standardized training]]></article-title>
<source><![CDATA[JAMA Otolaryngol Head Neck Sur.]]></source>
<year>2013</year>
<volume>139</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1111-7</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kneebone]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Practice, rehearsal, and performance: An approach for simulation-based surgical and procedure training]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2009</year>
<volume>302</volume>
<numero>20</numero>
<issue>20</issue>
<page-range>2190-2</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Voelker]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Medical simulation gets real]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2009</year>
<volume>302</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1336-8</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Botden]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Torab]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Buzink]]></surname>
<given-names><![CDATA[SN]]></given-names>
</name>
<name>
<surname><![CDATA[Jakimowicz]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The importance of haptic feedback in laparoscopic suturing training and the additive value of virtual reality simulation]]></article-title>
<source><![CDATA[Surg Endosc]]></source>
<year>2008</year>
<volume>22</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1214-22</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vaughan]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Dubey]]></surname>
<given-names><![CDATA[VN]]></given-names>
</name>
<name>
<surname><![CDATA[Wee]]></surname>
<given-names><![CDATA[MY]]></given-names>
</name>
<name>
<surname><![CDATA[Isaacs]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Towards a realistic in vitro experience of epidural Tuohy needle insertion]]></article-title>
<source><![CDATA[Proc Inst Mech Eng H]]></source>
<year>2013</year>
<volume>227</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>767-77</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Lorenzo]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Koseki]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[De Momi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Chinzei]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Okamura]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coaxial needle insertion assistant with enhanced force feedback]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>2013</year>
<volume>60</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>379-89</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Magill]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Byl]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Hinds]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Agassounon]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Pratt]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Hess]]></surname>
<given-names><![CDATA[PE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A novel actuator for simulation of epidural anesthesia and other needle insertion procedures]]></article-title>
<source><![CDATA[Simul Healthc]]></source>
<year>2010</year>
<volume>5</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>179-84</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lim]]></surname>
<given-names><![CDATA[YJ]]></given-names>
</name>
<name>
<surname><![CDATA[Valdivia]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Tardella]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[MR fluid haptic system for regional anesthesia training simulation system]]></article-title>
<source><![CDATA[Stud Health Technol Inform]]></source>
<year>2008</year>
<volume>132</volume>
<page-range>248-53</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hu]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lim]]></surname>
<given-names><![CDATA[YJ]]></given-names>
</name>
<name>
<surname><![CDATA[Tardella]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Warren]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Localized virtual patient model for regional anesthesia simulation training system]]></article-title>
<source><![CDATA[Stud Health Technol Inform]]></source>
<year>2007</year>
<volume>125</volume>
<page-range>185-90</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamstra]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dubrowski]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Backstein]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Teaching technical skills to surgical residents: A survey of empirical research]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2006</year>
<volume>449</volume>
<page-range>108-15</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mudumbai]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Fanning]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Howard]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Gaba]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of medical simulation to explore equipment failures and human-machine interactions in anesthesia machine pipeline supply crossover]]></article-title>
<source><![CDATA[Anesth Analg]]></source>
<year>2010</year>
<volume>110</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1292-6</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fanning]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Gaba]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The role of debriefing in simulation-based learning]]></article-title>
<source><![CDATA[Simul Healthc]]></source>
<year>2007</year>
<volume>2</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>115-25</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Magee]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ratnalingam]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kessel]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A training system for ultrasound-guided needle insertion procedures]]></article-title>
<source><![CDATA[Med Image Comput Comput Assist Interv]]></source>
<year>2007</year>
<volume>10</volume>
<page-range>566-74</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hocking]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hebard]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mitchell]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year>2011</year>
<volume>36</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>162-70</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chin]]></surname>
<given-names><![CDATA[KJ1]]></given-names>
</name>
<name>
<surname><![CDATA[Perlas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[VW]]></given-names>
</name>
<name>
<surname><![CDATA[Brull]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year>2008</year>
<volume>33</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>532-44</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosenberg]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[Popovic]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Albert]]></surname>
<given-names><![CDATA[DB]]></given-names>
</name>
<name>
<surname><![CDATA[Altman]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Marshall]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Sommer]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Three partial-task simulators for teaching ultrasound-guided regional anesthesia]]></article-title>
<source><![CDATA[Reg Anesth Pain Med]]></source>
<year>2012</year>
<volume>37</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>106-10</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Freschi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Parrini]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Dinelli]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hybrid simulation using mixed reality for interventional ultrasound imaging training]]></article-title>
<source><![CDATA[Int J Comput Assist Radiol Surg]]></source>
<year>2015</year>
<volume>10</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1109-15</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feifer]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Al-Ammari]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kovac]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Delisle]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Carrier]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Anidjar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized controlled trial of virtual reality and hybrid simulation for robotic surgical training]]></article-title>
<source><![CDATA[BJU Int]]></source>
<year>2011</year>
<volume>108</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1652-6</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tavakol]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Mohagheghi]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Dennick]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessing the skills of surgical residents using simulation]]></article-title>
<source><![CDATA[J Surg Educ]]></source>
<year>2008</year>
<volume>65</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>77-83</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Epstein]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment in medical education]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2007</year>
<volume>356</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>387-96</page-range></nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Uppal]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Kearns]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[McGrady]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of M43B Lumbar puncture simulator-II as a training tool for identification of the epidural space and lumbar puncture]]></article-title>
<source><![CDATA[Anaesthesia]]></source>
<year>2011</year>
<volume>66</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>493-6</page-range></nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Capogna]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Stirparo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Caniggia]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of a new training device to simulate the epidural and subarachnoid spaces for neuraxial anesthesia techniques]]></article-title>
<source><![CDATA[Minerva Anestesiol]]></source>
<year>2013</year>
<volume>79</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>385-90</page-range></nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weller]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simulation in undergraduate medical education: Bridging the gap between theory and practice]]></article-title>
<source><![CDATA[Med Educ]]></source>
<year>2004</year>
<volume>38</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>32-8</page-range></nlm-citation>
</ref>
<ref id="B54">
<label>54</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lundy]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The present opportunities for medical men in anaesthesia]]></article-title>
<source><![CDATA[Can Med Assoc J]]></source>
<year>1937</year>
<volume>37</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>552-4</page-range></nlm-citation>
</ref>
<ref id="B55">
<label>55</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lundy]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of local anesthetics]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>1936</year>
<volume>107</volume>
<numero>18</numero>
<issue>18</issue>
<page-range>1464-9</page-range></nlm-citation>
</ref>
<ref id="B56">
<label>56</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lundy]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diagnostic and therapeutic nerve block in general practice]]></article-title>
<source><![CDATA[Northwest Med]]></source>
<year>1951</year>
<volume>50</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>577-82</page-range></nlm-citation>
</ref>
<ref id="B57">
<label>57</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lundy]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cancer Pain]]></article-title>
<source><![CDATA[J Lancet]]></source>
<year>1964</year>
<volume>84</volume>
<page-range>15-7</page-range></nlm-citation>
</ref>
<ref id="B58">
<label>58</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kopp]]></surname>
<given-names><![CDATA[SL]]></given-names>
</name>
<name>
<surname><![CDATA[Horlocker]]></surname>
<given-names><![CDATA[TT]]></given-names>
</name>
<name>
<surname><![CDATA[Bacon]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The contribution of John Lundy in the development of peripheral and neuraxial nerve blocks at the Mayo Clinic: 1925-1940]]></article-title>
<source><![CDATA[M.A. Regional Anesthesia & Pain Medicine]]></source>
<year>2002</year>
<volume>27</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>322-6</page-range></nlm-citation>
</ref>
<ref id="B59">
<label>59</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bonica]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Teaching residents diagnostic and therapeutic nerve blocks]]></article-title>
<source><![CDATA[Curr Res Anesth Analg]]></source>
<year>1955</year>
<volume>34</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>202-13</page-range></nlm-citation>
</ref>
<ref id="B60">
<label>60</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bonica]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Management of intractable pain with analgesic blocks]]></article-title>
<source><![CDATA[J Am Med Assoc]]></source>
<year>1952</year>
<volume>150</volume>
<numero>16</numero>
<issue>16</issue>
<page-range>1581-6</page-range></nlm-citation>
</ref>
<ref id="B61">
<label>61</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bonica]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nerve blocks as an aid in the diagnosis and therapy of disease]]></article-title>
<source><![CDATA[Northwest Med]]></source>
<year>1950</year>
<volume>49</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>593-6</page-range></nlm-citation>
</ref>
<ref id="B62">
<label>62</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manchikanti]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Boswell]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
<name>
<surname><![CDATA[Raj]]></surname>
<given-names><![CDATA[PP]]></given-names>
</name>
<name>
<surname><![CDATA[Racz]]></surname>
<given-names><![CDATA[GB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evolution of interventional pain management]]></article-title>
<source><![CDATA[Pain Physician]]></source>
<year>2003</year>
<volume>6</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>485-94</page-range></nlm-citation>
</ref>
<ref id="B63">
<label>63</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manchikanti]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Heavner]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Racz]]></surname>
<given-names><![CDATA[GB]]></given-names>
</name>
<name>
<surname><![CDATA[Mekhail]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Schultz]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Hansen]]></surname>
<given-names><![CDATA[HC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Methods for evidence synthesis in interventional pain management]]></article-title>
<source><![CDATA[Pain Physician]]></source>
<year>2003</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>89-111</page-range></nlm-citation>
</ref>
<ref id="B64">
<label>64</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<source><![CDATA[Medicina del Dolor: Perspectiva Internacional]]></source>
<year>2015</year>
<page-range>2-20</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B65">
<label>65</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Breivik]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Collett]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Ventafridda]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gallacher]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survey of chronic pain in Europe: Prevalence, impact on daily life, and treatment]]></article-title>
<source><![CDATA[Eur J Pain]]></source>
<year>2006</year>
<volume>10</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>287-333</page-range></nlm-citation>
</ref>
<ref id="B66">
<label>66</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gouvitsos]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Vallet]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Scherpereel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anesthesia simulators: benefits and limits of experience gained at several European university hospitals]]></article-title>
<source><![CDATA[Ann Fr Anesth Reanim]]></source>
<year>1999</year>
<volume>18</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>787-95</page-range></nlm-citation>
</ref>
<ref id="B67">
<label>67</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schwid]]></surname>
<given-names><![CDATA[HA]]></given-names>
</name>
<name>
<surname><![CDATA[Rooke]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Carline]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Steadman]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Murray]]></surname>
<given-names><![CDATA[WB]]></given-names>
</name>
<name>
<surname><![CDATA[Olympio]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of anesthesia residents using mannequin-based simulation: A multiinstitutional study]]></article-title>
<source><![CDATA[Anesthesiology]]></source>
<year>2002</year>
<volume>97</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1434-44</page-range></nlm-citation>
</ref>
<ref id="B68">
<label>68</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Murray]]></surname>
<given-names><![CDATA[DJ1]]></given-names>
</name>
<name>
<surname><![CDATA[Boulet]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Avidan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kras]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Henrichs]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Woodhouse]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Performance of residents and anesthesiologists in a simulation-based skill assessment]]></article-title>
<source><![CDATA[Anesthesiology]]></source>
<year>2007</year>
<volume>107</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>705-13</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
