<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1698-4447</journal-id>
<journal-title><![CDATA[Medicina Oral, Patología Oral y Cirugía Bucal (Ed. impresa)]]></journal-title>
<abbrev-journal-title><![CDATA[Med. oral patol. oral cir. bucal (Ed.impr.)]]></abbrev-journal-title>
<issn>1698-4447</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Española de Medicina Oral]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1698-44472005000100009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Caracterización físico-química de la superficie de 9 implantes dentales con 3 distintos tratamientos de superficie]]></article-title>
<article-title xml:lang="en"><![CDATA[Physico-chemical characterization of the surface of 9 dental implants with 3 different surface treatments]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Rius]]></surname>
<given-names><![CDATA[Daniel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García Saban]]></surname>
<given-names><![CDATA[F. Javier]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Impladent S.L. Departamento Científico ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>02</month>
<year>2005</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>02</month>
<year>2005</year>
</pub-date>
<volume>10</volume>
<numero>1</numero>
<fpage>48</fpage>
<lpage>57</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S1698-44472005000100009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S1698-44472005000100009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S1698-44472005000100009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Existen diversos tratamientos de superficie aplicados a los implantes dentales. El objetivo del presente estudio es comparar las características físico-químicas de la superficie de implantes dentales de titanio sometidos a diversos tratamientos de superficie. 9 implantes dentales procedentes del mismo lote de fabricación fueron separados en 3 grupos y sometidos a 3 tipos de tratamiento de superficie diferentes: mecanizado, grabado ácido y un ataque químico denominado Avantblast®. Las superficies obtenidas fueron observadas mediante microscopía electrónica de barrido y microscopía confocal, y caracterizadas químicamente mediante energía dispersiva de rayos X y espectrometría de fotoelectrones. Resultados: Las superficies grabadas al ácido y las tratadas con ataque químico fueron más rugosas que las mecanizadas. La composición química superficial fue diferente entre procesos, en la superficie con el tratamiento de ataque químico existieron menos impurezas y un mayor espesor de la capa de óxido de titanio. Conclusiones: La rugosidad superficial de los implantes dentales de titanio y el espesor de la capa de óxido de titanio se pueden incrementar mediante un adecuado tratamiento superficial de ataque químico.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[There are many surface treatments applied to dental implants. The aim of the present investigation is to compare the physico-chemical characteristics of titanium dental implant surfaces with different surface treatments. 9 dental implants from the same batch were divided in 3 groups and received 3 different surface treatments: machined, acid etched and a new chemical surface treatment called Avantblast®. Scanning electron microscopy and confocal microscopy were used to image the treated surfaces, and energy-dispersive spectrometry and X-ray photoelectron spectrometry to provide a chemical characterization of the surfaces. Results: The acid etched and chemical etched surfaces had an increased roughness over the machined one. Surface chemical composition had differences between processes, as the surface with the new treatment presented a reduced level of impurities and increased thickness of the titanium oxide layer Conclusions: Surface roughness of titanium dental implants and thickness of the titanium oxide layer can be increased with a suitable surface treatment.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Implantes dentales]]></kwd>
<kwd lng="es"><![CDATA[tratamiento de superficie]]></kwd>
<kwd lng="es"><![CDATA[rugosidad]]></kwd>
<kwd lng="es"><![CDATA[óxido de titanio]]></kwd>
<kwd lng="en"><![CDATA[Dental implants]]></kwd>
<kwd lng="en"><![CDATA[surface treatment]]></kwd>
<kwd lng="en"><![CDATA[roughness]]></kwd>
<kwd lng="en"><![CDATA[titanium oxide]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font size=5><b> Caracterizaci&oacute;n f&iacute;sico-qu&iacute;mica de la superficie de 9 implantes dentales con 3 distintos tratamientos de superficie</b></font>        <P><b>Daniel Rodr&iacute;guez Rius <sup>(1)</sup>, F. Javier Garc&iacute;a Saban <sup> (2)</sup></b></P>        <P>(1) Dr. Ingeniero Industrial. Responsable del Departamento Cient&iacute;fico, Impladent S.L.    <br> (2) M&eacute;dico Odont&oacute;logo. Director del Departamento Cient&iacute;fico, Impladent S.L.</P>  <font size="2"><i>Correspondencia</i>:&nbsp;    <br>        Daniel Rodr&iacute;guez&nbsp;    <br>        Departamento Cient&iacute;fico, Impladent S.L.&nbsp;    <br>        Pol&iacute;gono Industrial Mas d&#146;en Cisa; c/ Gato    P&eacute;rez, 3-9&nbsp;    <br>        08181 - Sentmenat (Barcelona)&nbsp;    <br>        Tel 902 20 14 13 / Fax 902 259 260&nbsp;    <br>        e-mail: <a href="mailto:impladent@defcon.es">impladent@defcon.es</a></font>     ]]></body>
<body><![CDATA[<p><font size="2">Recibido: 12/05/2003 Aceptado: 15/10/2003</font></p>      <p aling="center">   <table border="1" width="48%">     <tr>       <td width="100%"><font size="2"> Rodr&iacute;guez-Rius D, Garc&iacute;a-Saban         F.J. Caracterizaci&oacute;n f&iacute;sico-qu&iacute;mica de la superficie de 9 implantes dentales con 3 distintos tratamientos de superficie. Med Oral Patol Oral Cir Bucal 2005;10:58-65.</font>    <br>         <font size="1" face="Arial">  &copy; Medicina Oral S. L. C.I.F. B 96689336 - ISSN 1137 - 2834</font></td>     </tr>   </table>     <P>&nbsp;</P>      <P><b>RESUMEN</b></P>      <P>Existen diversos tratamientos de superficie aplicados a los implantes dentales. El objetivo del presente estudio es comparar las caracter&iacute;sticas f&iacute;sico-qu&iacute;micas de la superficie de implantes dentales de titanio sometidos a diversos tratamientos de superficie. 9 implantes dentales procedentes del mismo lote de fabricaci&oacute;n fueron separados en 3 grupos y sometidos a 3 tipos de tratamiento de superficie diferentes: mecanizado, grabado &aacute;cido y un ataque qu&iacute;mico denominado Avantblast&reg;. Las superficies obtenidas fueron observadas mediante microscop&iacute;a electr&oacute;nica de barrido y microscop&iacute;a confocal, y caracterizadas qu&iacute;micamente mediante energ&iacute;a dispersiva de rayos X y espectrometr&iacute;a de fotoelectrones.    <br> Resultados:    <br> Las superficies grabadas al &aacute;cido y las tratadas con ataque qu&iacute;mico fueron m&aacute;s rugosas que las mecanizadas. La composici&oacute;n qu&iacute;mica superficial fue diferente entre procesos, en la superficie con el tratamiento de ataque qu&iacute;mico existieron menos impurezas y un mayor espesor de la capa de &oacute;xido de titanio.    <br> Conclusiones:    <br> La rugosidad superficial de los implantes dentales de titanio y el espesor de la capa de &oacute;xido de titanio se pueden incrementar mediante un adecuado tratamiento superficial de ataque qu&iacute;mico.</P>        ]]></body>
<body><![CDATA[<P><i><b>Palabras clave</b>: Implantes dentales, tratamiento de superficie, rugosidad, &oacute;xido de titanio</i></P>        <P>&nbsp;</P>        <P><b>INTRODUCCION</b></P>        <P>En los &uacute;ltimos a&ntilde;os han aparecido diversos tratamientos de superficie aplicados a implantes dentales para aumentar la rugosidad superficial del implante, como TiOblast<sup>&reg;</sup>(1), SLA<sup>&reg;</sup>(2), Osseotite<sup>&reg;</sup>(3) o TiUnite<sup>&reg;</sup>(4), entre otros. La aplicaci&oacute;n de tratamientos superficiales para obtener aumento de la rugosidad superficial de los implantes dentales (5-8), demuestran que la osteointegraci&oacute;n del implante a corto y medio plazo se ve favorecida por una superficie de rugosidad microm&eacute;trica. Esta mejor&iacute;a parece estar ligada, seg&uacute;n diversos estudios experimentales (8-11), a la existencia en la superficie del implante de microrrugosidades favorecedoras de la adhesi&oacute;n celular, dando lugar a una mayor diferenciaci&oacute;n celular y a una mayor expresi&oacute;n de los osteoblastos. Este efecto tiene como consecuencia una r&aacute;pida regeneraci&oacute;n y una mejor calidad del tejido  &oacute;seo.</P>      <P>Otras modificaciones de la superficie surgidas en los &uacute;ltimos a&ntilde;os est&aacute;n enfocadas a obtener un aumento del espesor y de la cristalinidad de la capa superficial de &oacute;xido de titanio, ya que algunos estudios sugieren una relaci&oacute;n entre el incremento del espesor y/o cristalinidad de la capa de &oacute;xido y mayor adsorci&oacute;n de prote&iacute;nas a la superficie (12, 13), mayor diferenciaci&oacute;n y crecimiento de los osteoblastos (14, 15) y mayor osteointegraci&oacute;n de implantes tratados (16, 17).</P>      <P>Se ha desarrollado un nuevo tratamiento de superficie, Avantblast&reg; (Impladent, Sentmenat, Espa&ntilde;a), que une las mejoras en la respuesta osteobl&aacute;stica obtenidas con un incremento de la rugosidad con las obtenidas con un mayor espesor y cristalinidad de la capa superficial de &oacute;xido de titanio. El incremento de rugosidad se consigue mediante homogeneizaci&oacute;n previa de tensiones superficiales y un ataque qu&iacute;mico de la superficie, mientras que el incremento de espesor y de la cristalinidad de la capa de &oacute;xido de titanio se logra mediante tratamiento t&eacute;rmico (14, 18, 19). En este art&iacute;culo se estudia la superficie de implantes dentales mecanizados sin tratar, con grabado &aacute;cido y con el nuevo tratamiento Avantblast&reg;. Se ha examinado la morfolog&iacute;a, la composici&oacute;n qu&iacute;mica superficial y la rugosidad creada por los diferentes tratamientos, as&iacute; como el espesor de la capa de &oacute;xido de titanio.</P>        <P><b>MATERIALES Y MÉTODOS</b></P>      <P>El estudio se realiz&oacute; sobre 9 implantes modelo Defcon<sup>TM</sup> TSA<sup>&reg;</sup> (Impladent, Sentmenat, Espa&ntilde;a), mecanizados en titanio grado 2. Tras un lavado posterior se prepararon 3 lotes de 3 implantes. </P>      <P>El primer lote de 3 implantes (denominado &#147;mecanizado&#148;) no recibi&oacute; ning&uacute;n tratamiento superficial. El segundo lote (denominado &#147;grabado&#148;) fue sometido a grabado &aacute;cido, consistente en un ataque qu&iacute;mico de la superficie del titanio con una disoluci&oacute;n de &aacute;cido fluorh&iacute;drico, seguido de pasivado con una disoluci&oacute;n de &aacute;cido fluorh&iacute;drico y n&iacute;trico seg&uacute;n el est&aacute;ndar ASTM (<i>American Standard for Testing of Materials</i>) F86. El tercer lote (denominado &#147;Avantblast&#148;) fue sometido a un tratamiento superficial en dos fases. En la primera fase, tras un proceso de homogeneizaci&oacute;n de tensiones, se aplic&oacute; un ataque qu&iacute;mico a la superficie del implante con una disoluci&oacute;n de &aacute;cido sulf&uacute;rico y fluorh&iacute;drico a elevada temperatura. En la segunda fase, se procedi&oacute; a someter el implante a un tratamiento t&eacute;rmico en horno.</P>      <P>Las muestras fueron introducidas en envases estancos y se irradiaron para su esterilizaci&oacute;n con una dosis m&iacute;nima de rayos gamma de 25kGy, procedentes de una fuente de cobalto-60 (Aragogamma S.A., Granollers, Espa&ntilde;a). Despu&eacute;s las muestras fueron analizadas en la zona del implante dise&ntilde;ada para entrar en contacto con el hueso sin ning&uacute;n otro tipo de preparaci&oacute;n. </P>      ]]></body>
<body><![CDATA[<P>El acabado superficial de los tratamientos fue estudiado con un microscopio electr&oacute;nico de barrido Jeol JSM-840 (Serveis Cient&iacute;fico-T&egrave;cnics, Universitat de Barcelona). El potencial del ca&ntilde;&oacute;n de electrones fue fijado a 15kV, con magnificaci&oacute;n de 14 a 10.000 aumentos.</P>      <P>La composici&oacute;n qu&iacute;mica superficial fue estudiada con dos t&eacute;cnicas complementarias en una zona fresada plana del extremo apical (un implante por lote). Se analiz&oacute; la composici&oacute;n qu&iacute;mica superficial mediante la t&eacute;cnica de energ&iacute;a dispersiva de rayos X (EDS) con un equipo EDS Link-Inca conectado a un microscopio electr&oacute;nico de barrido Leica Electroscan 360 (Serveis Cient&iacute;fico-T&egrave;cnics, Universitat de Barcelona). Paralelamente, tambi&eacute;n se analiz&oacute; mediante espectrometr&iacute;a de fotoelectrones (XPS) con un equipo Physical Electronics 5500 (Serveis Cient&iacute;fico-T&egrave;cnics, Universitat de Barcelona). Esta t&eacute;cnica permite determinar la composici&oacute;n qu&iacute;mica superficial de una muestra en un espesor nanom&eacute;trico. El equipo trabaj&oacute; con una fuente de emisi&oacute;n con monocromador de rayos X en la banda K&#945; del aluminio, en un vac&iacute;o ultra-alto de 0,6&#183;10<sup>-6</sup> Pa. El &aacute;ngulo de detecci&oacute;n fue de 90&#186;. La calibraci&oacute;n del espectr&oacute;metro se realiz&oacute; con el pico Ag3d5/2 (367,8eV) y con 0,44eV de amplitud a media altura del pico con la fuente de aluminio como fuente de excitaci&oacute;n.  Se utiliz&oacute; un ca&ntilde;&oacute;n de iones de arg&oacute;n para el decapado de la muestra dentro de la c&aacute;mara y la medida del espesor de la capa de &oacute;xido de titanio, con una velocidad promedio de decapado de 6nm/min. </P>      <P>La rugosidad se midi&oacute;, tanto en superficie como sobre una l&iacute;nea o perfil, en tres zonas de la rosca y en la zona fresada plana del extremo apical (un implante por lote) con un equipo Sensofar<sup>&reg;</sup>  PLµ de microscop&iacute;a confocal con luz blanca (Sensofar, Terrassa, Espa&ntilde;a). Este equipo consiste en un microscopio Nikon L150 con objetivo SLWD20x y un programa de reconstrucci&oacute;n y an&aacute;lisis. Este equipo consigue una reproducibilidad vertical inferior a 20nm y una resoluci&oacute;n lateral de 0,91µm. </P>      <P>En cada zona se recogi&oacute;, como par&aacute;metros de rugosidad en &aacute;rea, la rugosidad media (S<sub>a</sub>), la media de la ra&iacute;z cuadr&aacute;tica de la rugosidad (S<sub>q</sub>), la altura m&aacute;xima (S<sub>p</sub>), el volumen vac&iacute;o por unidad de superficie (S<sub>v</sub>) y la m&aacute;xima distancia pico-valle (S<sub>t</sub>). En perfil, tras aplicar un filtro gaussiano y un <i> cut-off</i> de 800 µm a los perfiles medidos seg&uacute;n el est&aacute;ndar DIN 4768, se recogi&oacute; la rugosidad media (R<sub>a</sub>), la media de la ra&iacute;z cuadr&aacute;tica de la rugosidad (R<sub>q</sub>), la altura m&aacute;xima (R<sub>p</sub>), la profundidad m&aacute;xima (R<sub>v</sub>), la m&aacute;xima distancia pico-valle (R<sub>t</sub>) y el espaciado medio de los picos (S<sub>m</sub>). Se aplic&oacute; un an&aacute;lisis de variancia (ANOVA) y el comparativo posthoc de Tukey al par&aacute;metro S<sub>a</sub> para estudiar las variaciones entre lotes.</P>        <P><b>RESULTADOS</b></P>      <P>El an&aacute;lisis de los tres lotes de implantes mostr&oacute; la existencia de diferencias sustanciales en las propiedades superficiales tras la aplicaci&oacute;n de los tratamientos. </P>      <P>La <a href="/img/medicor/v10n1/09/image04.gif" target="_blank"> figura 1</a> presenta las im&aacute;genes de las diferentes superficies estudiadas. A bajos aumentos, todos los implantes presentaron una geometr&iacute;a homog&eacute;nea y definida. Sin embargo, a 2.000 aumentos se hicieron evidentes importantes diferencias en la topograf&iacute;a. Los implantes del lote &#147;mecanizado&#148; mostraron una superficie con marcas del mecanizado de la superficie en forma de valles paralelos (<a href="/img/medicor/v10n1/09/image04.gif" target="_blank">figura 1a</a>). Los implantes del lote &#147;grabado&#148;, con mayor rugosidad, presentaron un acabado superficial en forma de bloques, debido al ataque preferencial del &aacute;cido fluorh&iacute;drico (<a href="/img/medicor/v10n1/09/image04.gif" target="_blank">figura 1b</a>), mientras que en el lote &#147;Avantblast&#148; se observ&oacute; una rugosidad en forma de concavidades con bordes externos agudos y una porosidad acentuada distribuida de forma homog&eacute;nea, debida a la acci&oacute;n del reactivo (<a href="/img/medicor/v10n1/09/image04.gif" target="_blank">figura 1c</a>).</P>      <P>Las mediciones de la composici&oacute;n qu&iacute;mica en superficie mediante EDS no permitieron discriminar los tratamientos analizados, ya que en los tres lotes detect&oacute; &uacute;nicamente la presencia de titanio y de ox&iacute;geno. Por el contrario, el an&aacute;lisis con XPS permiti&oacute; detectar diferencias entre los tres tratamientos (tabla 1). Los resultados muestra una menor presencia de carbono y otras impurezas en el lote &#147;Avantblast&#148; respecto a otros tratamientos superficiales de implantes (20, 21).</P>      <P>La determinaci&oacute;n del espesor de la capa de &oacute;xido de titanio mostr&oacute; que los implantes del lote &#147;Avantblast&#148; tienen una capa que triplica el espesor obtenido con los otros tratamientos de superficie (<a href="#T1">tabla 1</a>). </P>      <P align="center"><a name="T1"><img border="0" src="/img/medicor/v10n1/09/image01.gif" width="729" height="503"></a> </P>      ]]></body>
<body><![CDATA[<P>Los par&aacute;metros de rugosidad de los implantes se muestran en las <a href="#T2"> tablas 2</a> y <a href="#t3"> 3</a> (media y desviaci&oacute;n tipo de las cuatro medidas tomadas por lote). Los lotes &#147;grabado&#148; y &#147;Avantblast&#148; mostraron unos valores de rugosidad estad&iacute;sticamente mayores (p-valor: 0,000) respecto al lote &#147;mecanizado&#148;. En este lote, la reducida rugosidad existente se debe a las ondulaciones producidas por el paso de la herramienta de mecanizado (<a href="/img/medicor/v10n1/09/image05.gif" target="_blank">figura 2a</a>). </P>      <P align="center"><a name="T2"><img border="0" src="/img/medicor/v10n1/09/image02.gif" width="481" height="293"></a> </P>      <P align="center"><a name="t3"><img border="0" src="/img/medicor/v10n1/09/image03.gif"></a> </P>      <P align="center">&nbsp; </P>      <P>En el implante del lote &#147;grabado&#148;, el ataque qu&iacute;mico incrementa la rugosidad hasta valores superiores al micr&oacute;metro (<a href="/img/medicor/v10n1/09/image05.gif" target="_blank">figura 2b</a>). Un componente importante de la rugosidad de la superficie con grabado &aacute;cido son picos y valles de valores destacados (caracterizados por los elevados valores de los par&aacute;metros S<sub>p</sub> y R<sub>p</sub>), que incrementan de forma notable el valor medio de rugosidad.</P>      <P>El implante del lote &#147;Avantblast&#148; (<a href="/img/medicor/v10n1/09/image05.gif" target="_blank">figura 2c</a>) present&oacute; valores de rugosidad estad&iacute;sticamente superiores a la superficie mecanizada y al grabado &aacute;cido seg&uacute;n el estad&iacute;stico comparativo de Tukey (p-valor &lt; 0,05). La rugosidad se debe al ataque qu&iacute;mico, si bien es m&aacute;s homog&eacute;nea que en el caso del grabado &aacute;cido, como mostr&oacute; la comparativa de los par&aacute;metros de distancia pico-valle en superficie y en perfil (S<sub>p </sub> y R<sub>p</sub>). </P>        <P><b>DISCUSIÓN</b></P>      <P>Diversos estudios (5, 22) han mostrado que un bajo valor de rugosidad superficial, como el medido en el implante del lote &#147;mecanizado&#148;, promueve la formaci&oacute;n de c&aacute;psula fibrosa alrededor del implante, produce una menor &aacute;rea de contacto hueso-implante y resulta en un torque de desinserci&oacute;n inferior al de superficies m&aacute;s rugosas. Por el contrario, rugosidades con Ra de un micr&oacute;metro o mayores, como los que presentan los implantes de los lotes &#147;grabado&#148; y &#147;Avantblast&#148;, mejoran la uni&oacute;n del hueso a la superficie del implante (5, 10).</P>      <P>La superficie Avantblast&reg; cumple los requerimientos relativos a la necesidad de que el implante presente una rugosidad tal que permita un buen anclaje de las c&eacute;lulas &oacute;seas (5-11, 23), adem&aacute;s de presentar una mayor homogeneidad que la superficie grabada. Adem&aacute;s, la morfolog&iacute;a se asemeja notablemente al ideal te&oacute;rico para la retenci&oacute;n del implante, deducido a partir de principios biomec&aacute;nicos, consistente en una superficie con pocillos redondeados (24).</P>      <P>El an&aacute;lisis qu&iacute;mico por XPS ha permitido detectar elementos presentes en la superficie no detectados con el EDS, ya que es una t&eacute;cnica m&aacute;s sensible. La presencia de contaminaci&oacute;n org&aacute;nica (carbono) en todas las superficies es inevitable, ya que los hidrocarburos presentes en la atm&oacute;sfera se adsorben de forma casi instant&aacute;nea en la superficie de titanio expuesta al aire. Ahora bien, un valor muy elevado de carbono puede ser indicativo de restos de refrigerante u otros contaminantes del proceso de mecanizado. La presencia de elementos no relacionados con el tratamiento de superficie, como sodio, cloro o silicio, tambi&eacute;n es indicativa de impurezas no eliminadas por el proceso de limpieza.</P>      ]]></body>
<body><![CDATA[<P>El incremento de espesor de la capa de &oacute;xido de titanio en el tratamiento Avantblast&reg; se consigue mediante la fase de tratamiento t&eacute;rmico por la mayor difusi&oacute;n de ox&iacute;geno en el titanio. El mayor espesor reduce la liberaci&oacute;n de iones al medio, ya que el &oacute;xido de titanio hace de barrera a la difusi&oacute;n de iones (25), y un mayor espesor de la capa de &oacute;xido reduce la liberaci&oacute;n de iones de forma exponencial (26, 27). </P>      <P>Tambi&eacute;n se ha relacionado el mayor espesor y/o cristalinidad del &oacute;xido de titanio con una mayor adsorci&oacute;n de ciertas prote&iacute;nas en la superficie (12, 15), lo que afecta a la respuesta celular. En concreto, los condrocitos son sensibles al grado de cristalinidad del TiO2 y su respuesta mejora con el espesor y/o cristalinidad (15). La respuesta in vivo al incremento de espesor de la capa de &oacute;xido de titanio tambi&eacute;n es positiva, ya que al duplicar el espesor de la capa de &oacute;xido mediante tratamiento t&eacute;rmico se dobl&oacute; la fuerza de uni&oacute;n del implante al hueso (14). </P>      <P>Por ello, se espera que la uni&oacute;n de estas dos modificaciones de la superficie del implante tenga como consecuencia un incremento de la osteointegraci&oacute;n y una mayor formaci&oacute;n de hueso en contacto con la superficie de los implantes tratados con Avantblast&reg; respecto a otras superficies.</P>        <P><b>CONCLUSIONES</b></P>      <P>La rugosidad superficial de los implantes dentales de titanio se puede incrementar mediante tratamientos superficiales de ataque qu&iacute;mico. El tratamiento de superficie Avantblast&reg;, adem&aacute;s de producir una rugosidad superficial de rango microm&eacute;trico, triplica el espesor de la capa de &oacute;xido de titanio respecto a la capa natural de &oacute;xido, reduciendo la presencia de impurezas en la superficie.</P>        <P><b>BIBLIOGRAFÍA</b></P>      <!-- ref --><P>1. Cooper LF, Masuda T, Whitson SW, Yliheikkila P, Felton DA. Formation of mineralizing osteoblast cultures on machined, titanium oxide grit-blasted, and plasma-sprayed titanium surfaces. Int J Oral Maxillofac Implants 1999;14:37-47.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950727&pid=S1698-4447200500010000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>2. Wilke HJ, Claes L, Steinemann S. The influence of various titanium surfaces on the interface shear strength between implants and bone. En: Heimke G, Solt&eacute;sz U, Lee AJC, eds. Advances in Biomaterials, v9. Amsterdam: Ed. Elsevier; 1990. p. 309-14.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950728&pid=S1698-4447200500010000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>3. Khang W, Feldman S, Hawley CE, Gunsolley J. A multi-center study comparing dual acid-etched and machined-surfaced implants in various bone qualities. J Periodontol 2001;72:1384-90.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950729&pid=S1698-4447200500010000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>4. Hall J, Lausmaa J. Properties of a new porous oxide surface on titanium implants. Applied Osseointegration Research 2000;1:5-8.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950730&pid=S1698-4447200500010000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>5. Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950731&pid=S1698-4447200500010000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>6. Wennerberg A, Albrektsson T, Lausmaa J. Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-um-sized particles of Al2O3. J Biomed Mater Res 1996;30:251-60.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950732&pid=S1698-4447200500010000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>7. Buser D, Nydegger T, Hirt HP, Cochran DL, Nolte LP. Removal torque value of titanium implants in the maxilla of miniature pigs. Int J Oral Maxillofac Implants 1998;13:611-9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950733&pid=S1698-4447200500010000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>8. Lazzara RJ. Bone response to dual acid-etched and machined titanium implant surfaces. En: Davies JE, ed. Bone Engineering. Toronto: Em Squared Incorporated; 2000. p. 381-90.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950734&pid=S1698-4447200500010000900008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>9. Cochran DL, Simpson J, Weber HP, Buser D. Attachment and growth of periodontal cells on smooth and rough titanium. Int. J Oral Maxillofac Implants 1994;9:289-97.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950735&pid=S1698-4447200500010000900009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>10. Martin JY, Schwartz Z, Hummert TW, Schraub DM, Simpson J, Lankford J et al. Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63). J Biomed Mater Res 1995; 29:389-401.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950736&pid=S1698-4447200500010000900010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>11. Orsini G, Assenza B, Scarano A, Piattelli M, Piattelli A. Surface analysis of machined versus sandblasted and acid-etched titanium implants. Int J Oral Maxillofac Implants 2000;15:779-84.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950737&pid=S1698-4447200500010000900011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>12. McAlarney ME, Oshiro MA, McAlarney CV. Effects of titanium dioxide passive film crystal structure, thickness, and crystallinity on C3 adsorption. Int J Oral Maxillofac Implants 1996; 11:73-80.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950738&pid=S1698-4447200500010000900012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>13. Sunny MC, Sharma CP. Titanium-protein interaction: changes with oxide layer thickness. J Biomater Appl 1991;6:89-98.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950739&pid=S1698-4447200500010000900013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>14. Hazan R, Brener R, Oron U. Bone growth to metal implants is regulated by their surface chemical properties. Biomaterials 1993;14:570-4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950740&pid=S1698-4447200500010000900014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>15. Boyan BD, Hummert TW, Kieswetter K, Schraub DM, Dean DD, Schwartz Z. Effect of titanium surface characteristics on chondrocytes and osteoblasts in vitro. Cell Mater 1995;5:323-35.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950741&pid=S1698-4447200500010000900015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>16. Larsson C, Thomsen P, Lausmaa J, Rodahl M, Kasemo B, Ericson LE. Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology. Biomaterials 1994;15:1062-74.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950742&pid=S1698-4447200500010000900016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>17. Sul YT, Johansson CB, Jeong Y, R&ouml;ser K, Wennerberg A, Albrektsson T. Oxidized implants and their influence on the bone response. J Mat Sci: Mater in Med 2002;12:1025-31.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950743&pid=S1698-4447200500010000900017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>18. Radegran J, Lausmaa J, Mattsson L, Rolander U, Kasemo B. Preparation of ultra-thin oxide windows on titanium for TEM analysis. J Electron Microsc Tech 1991;19:99-106.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950744&pid=S1698-4447200500010000900018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>19. Kilpadi DV, Lemons JE, Liu J, Raikar GN, Weimer JJ, Vohra Y. Cleaning and heat-treatment effects of unalloyed titanium implant surfaces. Int J Oral Maxillofac Implants 2000;15:219-30.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950745&pid=S1698-4447200500010000900019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>20. Wieland M, Sittig C, Brunette DM, Textor M, Spencer ND. Measurement and evaluation of the chemical composition and topography of titanium implant surfaces. En: Davies JE, ed. Bone Engineering. Toronto: Em Squared Incorporated; 2000. p. 163-82.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950746&pid=S1698-4447200500010000900020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>21. Massaro C, Rotolo P, de Riccardis F, Milella E, Napoli A, Wieland M et al. Comparative investigation of the surface properties of commercial titanium dental implants. Part I: chemical composition. J Mat Sci: Mater in Med 2002; 13:536-48.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950747&pid=S1698-4447200500010000900021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>22. Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Implan Res 1995;6:24-30.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950748&pid=S1698-4447200500010000900022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>23. Wennerberg A, Ektessabi A, Albrektsson T, Johansson C, Andersson B. A 1-year follow-up of implants of differing surface roughness placed in rabbit bone. Int J Oral Maxillofac Implants 1997;12:486-94.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950749&pid=S1698-4447200500010000900023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>24. Hansson S, Norton M. The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model. J Biomech 1999;32:829-36.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950750&pid=S1698-4447200500010000900024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>25. Li J. Behaviour of titanium and titania-based ceramics in vitro and in vivo. Biomaterials 1993;14:229-32.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950751&pid=S1698-4447200500010000900025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>26. Chang E, Lee TM. Effect of surface chemistries and characteristics of Ti6Al4V on the Ca and P adsorption and ion dissolution in Hank&#146;s ethylene diamine tetra-acetic acid solution. Biomaterials 2002;23:2917-25.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950752&pid=S1698-4447200500010000900026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P>27. Chen G, Wen X, Zhang N. Corrosion resistance and ion dissolution of titanium with different surface microroughness. Biomed Mater Eng 1998;8:61-74.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2950753&pid=S1698-4447200500010000900027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[Masuda]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Whitson]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
<name>
<surname><![CDATA[Yliheikkila]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Felton]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Formation of mineralizing osteoblast cultures on machined, titanium oxide grit-blasted, and plasma-sprayed titanium surfaces]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1999</year>
<volume>14</volume>
<page-range>37-47</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wilke]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Claes]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Steinemann]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of various titanium surfaces on the interface shear strength between implants and bone]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Heimke]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Soltész]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[AJC]]></given-names>
</name>
</person-group>
<source><![CDATA[Advances in Biomaterials]]></source>
<year>1990</year>
<volume>9</volume>
<page-range>309-14</page-range><publisher-loc><![CDATA[Amsterdam ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khang]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Feldman]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hawley]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
<name>
<surname><![CDATA[Gunsolley]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A multi-center study comparing dual acid-etched and machined-surfaced implants in various bone qualities]]></article-title>
<source><![CDATA[J Periodontol]]></source>
<year>2001</year>
<volume>72</volume>
<page-range>1384-90</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hall]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lausmaa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Properties of a new porous oxide surface on titanium implants]]></article-title>
<source><![CDATA[Applied Osseointegration Research]]></source>
<year>2000</year>
<volume>1</volume>
<page-range>5-8</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buser]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Schenk]]></surname>
<given-names><![CDATA[RK]]></given-names>
</name>
<name>
<surname><![CDATA[Steinemann]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fiorellini]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Fox]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Stich]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of surface characteristics on bone integration of titanium implants: A histomorphometric study in miniature pigs]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1991</year>
<volume>25</volume>
<page-range>889-902</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wennerberg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Albrektsson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Lausmaa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-um-sized particles of Al2O3]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1996</year>
<volume>30</volume>
<page-range>251-60</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buser]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Nydegger]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hirt]]></surname>
<given-names><![CDATA[HP]]></given-names>
</name>
<name>
<surname><![CDATA[Cochran]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Nolte]]></surname>
<given-names><![CDATA[LP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal torque value of titanium implants in the maxilla of miniature pigs]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1998</year>
<volume>13</volume>
<page-range>611-9</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lazzara]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bone response to dual acid-etched and machined titanium implant surfaces]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<source><![CDATA[Bone Engineering]]></source>
<year>2000</year>
<page-range>381-90</page-range><publisher-loc><![CDATA[Toronto ]]></publisher-loc>
<publisher-name><![CDATA[Em Squared Incorporated]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cochran]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Simpson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Weber]]></surname>
<given-names><![CDATA[HP]]></given-names>
</name>
<name>
<surname><![CDATA[Buser]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Attachment and growth of periodontal cells on smooth and rough titanium]]></article-title>
<source><![CDATA[Int. J Oral Maxillofac Implants]]></source>
<year>1994</year>
<volume>9</volume>
<page-range>289-97</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martin]]></surname>
<given-names><![CDATA[JY]]></given-names>
</name>
<name>
<surname><![CDATA[Schwartz]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Hummert]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Schraub]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Simpson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lankford]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63)]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1995</year>
<volume>29</volume>
<page-range>389-401</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orsini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Assenza]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Scarano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Piattelli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Piattelli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Surface analysis of machined versus sandblasted and acid-etched titanium implants]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2000</year>
<volume>15</volume>
<page-range>779-84</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McAlarney]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
<name>
<surname><![CDATA[Oshiro]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[McAlarney]]></surname>
<given-names><![CDATA[CV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of titanium dioxide passive film crystal structure, thickness, and crystallinity on C3 adsorption]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1996</year>
<volume>11</volume>
<page-range>73-80</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sunny]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Sharma]]></surname>
<given-names><![CDATA[CP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Titanium-protein interaction: changes with oxide layer thickness]]></article-title>
<source><![CDATA[J Biomater Appl]]></source>
<year>1991</year>
<volume>6</volume>
<page-range>89-98</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hazan]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Brener]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Oron]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bone growth to metal implants is regulated by their surface chemical properties]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1993</year>
<volume>14</volume>
<page-range>570-4</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boyan]]></surname>
<given-names><![CDATA[BD]]></given-names>
</name>
<name>
<surname><![CDATA[Hummert]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Kieswetter]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Schraub]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Dean]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
<name>
<surname><![CDATA[Schwartz]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of titanium surface characteristics on chondrocytes and osteoblasts in vitro]]></article-title>
<source><![CDATA[Cell Mater]]></source>
<year>1995</year>
<volume>5</volume>
<page-range>323-35</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Larsson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Thomsen]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lausmaa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rodahl]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kasemo]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Ericson]]></surname>
<given-names><![CDATA[LE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1994</year>
<volume>15</volume>
<page-range>1062-74</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sul]]></surname>
<given-names><![CDATA[YT]]></given-names>
</name>
<name>
<surname><![CDATA[Johansson]]></surname>
<given-names><![CDATA[CB]]></given-names>
</name>
<name>
<surname><![CDATA[Jeong]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Röser]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Wennerberg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Albrektsson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oxidized implants and their influence on the bone response]]></article-title>
<source><![CDATA[J Mat Sci: Mater in Med]]></source>
<year>2002</year>
<volume>12</volume>
<page-range>1025-31</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Radegran]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lausmaa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mattsson]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Rolander]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Kasemo]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preparation of ultra-thin oxide windows on titanium for TEM analysis]]></article-title>
<source><![CDATA[J Electron Microsc Tech]]></source>
<year>1991</year>
<volume>19</volume>
<page-range>99-106</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kilpadi]]></surname>
<given-names><![CDATA[DV]]></given-names>
</name>
<name>
<surname><![CDATA[Lemons]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Raikar]]></surname>
<given-names><![CDATA[GN]]></given-names>
</name>
<name>
<surname><![CDATA[Weimer]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Vohra]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cleaning and heat-treatment effects of unalloyed titanium implant surfaces]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2000</year>
<volume>15</volume>
<page-range>219-30</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wieland]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sittig]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Brunette]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Textor]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Spencer]]></surname>
<given-names><![CDATA[ND]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measurement and evaluation of the chemical composition and topography of titanium implant surfaces]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<source><![CDATA[Bone Engineering]]></source>
<year>2000</year>
<page-range>163-82</page-range><publisher-loc><![CDATA[Toronto ]]></publisher-loc>
<publisher-name><![CDATA[Em Squared Incorporated]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Massaro]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rotolo]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[de Riccardis]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Milella]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Napoli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wieland]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative investigation of the surface properties of commercial titanium dental implants: Part I: chemical composition]]></article-title>
<source><![CDATA[J Mat Sci: Mater in Med]]></source>
<year>2002</year>
<volume>13</volume>
<page-range>536-48</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wennerberg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Albrektsson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Andersson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Krol]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies]]></article-title>
<source><![CDATA[Clin Oral Implan Res]]></source>
<year>1995</year>
<volume>6</volume>
<page-range>24-30</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wennerberg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ektessabi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Albrektsson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Johansson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Andersson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A 1-year follow-up of implants of differing surface roughness placed in rabbit bone]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1997</year>
<volume>12</volume>
<page-range>486-94</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hansson]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The relation between surface roughness and interfacial shear strength for bone-anchored implants: A mathematical model]]></article-title>
<source><![CDATA[J Biomech]]></source>
<year>1999</year>
<volume>32</volume>
<page-range>829-36</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Behaviour of titanium and titania-based ceramics in vitro and in vivo]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1993</year>
<volume>14</volume>
<page-range>229-32</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of surface chemistries and characteristics of Ti6Al4V on the Ca and P adsorption and ion dissolution in Hank’s ethylene diamine tetra-acetic acid solution]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2002</year>
<volume>23</volume>
<page-range>2917-25</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Wen]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion resistance and ion dissolution of titanium with different surface microroughness]]></article-title>
<source><![CDATA[Biomed Mater Eng]]></source>
<year>1998</year>
<volume>8</volume>
<page-range>61-74</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>