<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1888-7546</journal-id>
<journal-title><![CDATA[Revista Andaluza de Medicina del Deporte]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Andal Med Deporte]]></abbrev-journal-title>
<issn>1888-7546</issn>
<publisher>
<publisher-name><![CDATA[Centro Andaluz de Medicina del Deporte]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1888-75462015000400004</article-id>
<article-id pub-id-type="doi">10.1016/j.ramd.2015.05.004</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Posicionamiento de la National Strength and Conditioning Association-Spain: entrenamiento con electroestimulación de cuerpo completo]]></article-title>
<article-title xml:lang="pt"><![CDATA[Posicionamento da National Strength and Conditioning Association-Spain: treinamento com eletroestimulação do corpo completo]]></article-title>
<article-title xml:lang="en"><![CDATA[National Strength and Conditioning Association-Spain position stand: whole-body electromyostimulation training]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Herrero]]></surname>
<given-names><![CDATA[A.J.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martín]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Benito]]></surname>
<given-names><![CDATA[P.J.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gonzalo-Martínez]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
<xref ref-type="aff" rid="A04"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Chulvi-Medrano]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<xref ref-type="aff" rid="A05"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García-López]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Europea Miguel de Cervantes Departamento de Ciencias de la Salud ]]></institution>
<addr-line><![CDATA[Valladolid ]]></addr-line>
<country>España</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Fundación Asociación de Parapléjicos y Grandes Minusválidos (Fundación ASPAYM) Castilla y León Centro de Investigación en Discapacidad Física ]]></institution>
<addr-line><![CDATA[Valladolid ]]></addr-line>
<country>España</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Politécnica de Madrid Facultad de Ciencias de la Actividad Física y del Deporte ]]></institution>
<addr-line><![CDATA[Madrid ]]></addr-line>
<country>España</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Asociación Profesional de Entrenamiento Personal Elements Research Group ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>España</country>
</aff>
<aff id="A05">
<institution><![CDATA[,Instituto Internacional del Deporte y las Ciencias Aplicadas  ]]></institution>
<addr-line><![CDATA[Valencia ]]></addr-line>
<country>España</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2015</year>
</pub-date>
<volume>8</volume>
<numero>4</numero>
<fpage>155</fpage>
<lpage>162</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_arttext&amp;pid=S1888-75462015000400004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_abstract&amp;pid=S1888-75462015000400004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.isciii.es/scielo.php?script=sci_pdf&amp;pid=S1888-75462015000400004&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El objetivo de este artículo fue establecer, a partir de una revisión sistemática sobre la metodología del entrenamiento y los efectos sobre el organismo de la electroestimulación de cuerpo completo (en inglés, whole body electromyostimulation [WB-EMS]), el posicionamiento de la National Strength and Conditioning Association (NSCA)-Spain al respecto. Se buscaron en PubMed, Web of Science, Physiotherapy Evidence Database y Google Académico estudios que aplicasen WB-EMS en miembro superior e inferior, describiendo claramente el protocolo. Se analizaron 9 artículos. El protocolo habitual de entrenamiento con WB-EMS consistió en 3 sesiones de 20-30 min cada 2 semanas (85 Hz y ratio contracción-reposo de 4-4 o 6-4 s). La WB-EMS parece un medio poco eficaz para mejorar la fuerza máxima y no hay evidencias rigurosas que indiquen que disminuya la grasa corporal. La relación entre riesgo asumido y beneficio aportado hace que sean más recomendables otros medios de entrenamiento para la mejora de la fuerza muscular y para la modificación de la composición corporal.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The aim of this paper was to establish the position of the Spanish delegation of the National Strength and Conditioning Association (NSCA)-Spain about the methodology of training and the effects on the body of whole-body electromyostimulation (WB-EMS), from a systematic review. We searched PubMed, Web of Science, Physiotherapy Evidence Database and Google Scholar studies applying WB-EMS in the upper and lower limbs, which clearly described the protocols. Nine studies were analyzed. The usual WB-EMS training protocol consisted of 3 sessions every two weeks, lasting 20-30 min (85 Hz with a contraction-rest ratio of 4-4 or 6-4 s). The WB-EMS seems few effective to improve maximum strength and there is lack of evidence about its benefit to decrease body fat. The relationship between risk and profit makes other training methods more appropriate to improve muscle strength and body composition.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[O objetivo deste artigo foi estabelecer, a partir de uma revisão sistemática sobre a metodologia do treinamento e os efeitos sobre o organismo da eletroestimulação de corpo completo (WB-EMS), o posicionamento do National Strength and Conditioning Association (NSCA)-Spain, a respeito. Buscou-se no PubMed, Web of Science, Physiotherapy Evidence Database e Google Acadêmico estudos que aplicassem WB-SEM em membro superior e inferior, descrevendo claramente o protocolo. Se analisaram 9 artigos. O protocolo habitual de treinamento com WB-EMS consistiu em 3 sessões de 20-30 min cada 2 semanas (85 Hz e relação de contração-repouso de 4-4 ou 6-4 s) A WB-EMS parece ser um meio pouco eficaz para melhorar a força máxima e não há evidencias rigorosas que indiquem que diminua a gordura corporal. A relação entre o risco assumido e benefício apontado faz com que outros métodos de treinamento sejam mais adequados para melhorar a força muscular e composição corporal.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Electroestimulación integral]]></kwd>
<kwd lng="es"><![CDATA[Chalecos de electroestimulación]]></kwd>
<kwd lng="es"><![CDATA[Electroestimulación de cuerpo completo]]></kwd>
<kwd lng="es"><![CDATA[Composición corporal]]></kwd>
<kwd lng="es"><![CDATA[Fuerza muscular]]></kwd>
<kwd lng="en"><![CDATA[Integral electromyostimulation]]></kwd>
<kwd lng="en"><![CDATA[Electromyostimulation vest]]></kwd>
<kwd lng="en"><![CDATA[Whole body electromyostimulation]]></kwd>
<kwd lng="en"><![CDATA[body composition]]></kwd>
<kwd lng="en"><![CDATA[Muscle strength]]></kwd>
<kwd lng="pt"><![CDATA[Eletroestimulação integral]]></kwd>
<kwd lng="pt"><![CDATA[Vestimenta de eletroestimulação]]></kwd>
<kwd lng="pt"><![CDATA[Eletroestimulação de corpo inteiro]]></kwd>
<kwd lng="pt"><![CDATA[Composição corporal]]></kwd>
<kwd lng="pt"><![CDATA[Força muscular]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p><a name="top"></a><b><font face="Verdana" size="2">ART&Iacute;CULO ESPECIAL</font></b></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="4"><b>Posicionamiento de la <i>National Strength and Conditioning Association</i>-Spain. Entrenamiento con electroestimulaci&oacute;n de cuerpo completo</b></font></p>     <p><font face="Verdana" size="4"><b>Posicionamento da <i>National Strength and Conditioning Association</i>-Spain. Treinamento com eletroestimula&ccedil;&atilde;o do corpo completo</b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>A.J. Herrero<sup>a,b</sup>, J. Mart&iacute;n<sup>a</sup>, P.J. Benito<sup>c</sup>, I. Gonzalo-Mart&iacute;nez<sup>c,d</sup>, I. Chulvi-Medrano<sup>e</sup>, D. Garc&iacute;a-L&oacute;pez<sup>a</sup> y NSCA Spain</b></font></p>     <p><font face="Verdana" size="2"><sup>a</sup> Departamento de Ciencias de la Salud, Universidad Europea Miguel de Cervantes, Valladolid, Espa&ntilde;a    <br><sup>b</sup> Centro de Investigaci&oacute;n en Discapacidad F&iacute;sica, Fundaci&oacute;n ASPAYM Castilla y Le&oacute;n, Valladolid, Espa&ntilde;a    <br><sup>c</sup> Facultad de Ciencias de la Actividad F&iacute;sica y del Deporte, Universidad Polit&eacute;cnica de Madrid, Madrid, Espa&ntilde;a    ]]></body>
<body><![CDATA[<br><sup>d</sup> Elements Research Group, Asociaci&oacute;n Profesional de Entrenamiento Personal, Espa&ntilde;a    <br><sup>e</sup> Instituto Internacional del Deporte y las Ciencias Aplicadas, Valencia, Espa&ntilde;a</font></p>     <p><font face="Verdana" size="2"><a href="#bajo">Direcci&oacute;n para correspondencia</a></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p> <hr size="1">    <p><font face="Verdana" size="2"><b>RESUMEN</b></font></p>     <p><font face="Verdana" size="2">El objetivo de este art&iacute;culo fue establecer, a partir de una revisi&oacute;n sistem&aacute;tica sobre la metodolog&iacute;a del entrenamiento y los efectos sobre el organismo de la electroestimulaci&oacute;n de cuerpo completo (en ingl&eacute;s, <i>whole body electromyostimulation</i> &#091;WB-EMS&#093;), el posicionamiento de la <i>National Strength and Conditioning Association</i> (NSCA)-Spain al respecto. Se buscaron en <i>PubMed, Web of Science, Physiotherapy Evidence Database</i> y Google Acad&eacute;mico estudios que aplicasen WB-EMS en miembro superior e inferior, describiendo claramente el protocolo. Se analizaron 9 art&iacute;culos. El protocolo habitual de entrenamiento con WB-EMS consisti&oacute; en 3 sesiones de 20-30 min cada 2 semanas (85 Hz y ratio contracci&oacute;n-reposo de 4-4 o 6-4 s). La WB-EMS parece un medio poco eficaz para mejorar la fuerza m&aacute;xima y no hay evidencias rigurosas que indiquen que disminuya la grasa corporal. La relaci&oacute;n entre riesgo asumido y beneficio aportado hace que sean m&aacute;s recomendables otros medios de entrenamiento para la mejora de la fuerza muscular y para la modificaci&oacute;n de la composici&oacute;n corporal.</font></p>     <p><font face="Verdana" size="2"><b>Palabras clave:</b> Electroestimulaci&oacute;n integral. Chalecos de electroestimulaci&oacute;n. Electroestimulaci&oacute;n de cuerpo completo. Composici&oacute;n corporal. Fuerza muscular.</font></p> <hr size="1">    <p><font face="Verdana" size="2"><b>ABSTRACT</b></font></p>     <p><font face="Verdana" size="2">The aim of this paper was to establish the position of the Spanish delegation of the National Strength and Conditioning Association (NSCA)-Spain about the methodology of training and the effects on the body of whole-body electromyostimulation (WB-EMS), from a systematic review. We searched PubMed, Web of Science, Physiotherapy Evidence Database and Google Scholar studies applying WB-EMS in the upper and lower limbs, which clearly described the protocols. Nine studies were analyzed. The usual WB-EMS training protocol consisted of 3 sessions every two weeks, lasting 20-30 min (85 Hz with a contraction-rest ratio of 4-4 or 6-4 s). The WB-EMS seems few effective to improve maximum strength and there is lack of evidence about its benefit to decrease body fat. The relationship between risk and profit makes other training methods more appropriate to improve muscle strength and body composition.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2"><b>Key words:</b> Integral electromyostimulation. Electromyostimulation vest. Whole body electromyostimulation. body composition. Muscle strength.</font></p> <hr size="1">    <p><font face="Verdana" size="2"><b>RESUMO</b></font></p>     <p><font face="Verdana" size="2">O objetivo deste artigo foi estabelecer, a partir de uma revis&atilde;o sistem&aacute;tica sobre a metodologia do treinamento e os efeitos sobre o organismo da eletroestimula&ccedil;&atilde;o de corpo completo (WB-EMS), o posicionamento do <i>National Strength and Conditioning Association</i> (NSCA)-Spain, a respeito. Buscou-se no <i>PubMed, Web of Science, Physiotherapy Evidence Database</i> e Google Acad&ecirc;mico estudos que aplicassem WB-SEM em membro superior e inferior, descrevendo claramente o protocolo. Se analisaram 9 artigos. O protocolo habitual de treinamento com WB-EMS consistiu em 3 sess&otilde;es de 20-30 min cada 2 semanas (85 Hz e rela&ccedil;&atilde;o de contra&ccedil;&atilde;o-repouso de 4-4 ou 6-4 s) A WB-EMS parece ser um meio pouco eficaz para melhorar a for&ccedil;a m&aacute;xima e n&atilde;o h&aacute; evidencias rigorosas que indiquem que diminua a gordura corporal. A rela&ccedil;&atilde;o entre o risco assumido e benef&iacute;cio apontado faz com que outros m&eacute;todos de treinamento sejam mais adequados para melhorar a for&ccedil;a muscular e composi&ccedil;&atilde;o corporal.</font></p>     <p><font face="Verdana" size="2"><b>Palavras-chave:</b> Eletroestimula&ccedil;&atilde;o integral. Vestimenta de eletroestimula&ccedil;&atilde;o. Eletroestimula&ccedil;&atilde;o de corpo inteiro. Composi&ccedil;&atilde;o corporal. For&ccedil;a muscular.</font></p> <hr size="1">     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p><font face="Verdana" size="2">La electroestimulaci&oacute;n es una t&eacute;cnica utilizada desde hace d&eacute;cadas en los &aacute;mbitos de la rehabilitaci&oacute;n y del entrenamiento. Esta t&eacute;cnica puede ser aplicada de forma invasiva, por medio de agujas (p. ej., electroacupuntura), o de forma no invasiva por medio de electrodos de superficie (p. ej., TENS). Cuando se aplica por medio de electrodos, puede contraer directamente la musculatura (electroestimulaci&oacute;n muscular) o contraerla indirectamente mediante la activaci&oacute;n de las ramas terminales de los axones neurales (electroestimulaci&oacute;n neuromuscular &#091;EMS&#093;). La EMS se suele aplicar de forma local mediante la colocaci&oacute;n de electrodos en el vientre muscular, lo m&aacute;s cercanos posible al punto motor. Diferentes art&iacute;culos de revisi&oacute;n han mostrado la eficacia de la EMS local para mejorar la fuerza muscular y producir adaptaciones neurales en sujetos sanos<sup>1-6</sup>, en pacientes tras una intervenci&oacute;n quir&uacute;rgica<sup>7-9</sup> y en pacientes con enfermedades cr&oacute;nicas<sup>10,11</sup>. La EMS tambi&eacute;n puede aplicarse de forma no local, mediante la utilizaci&oacute;n de trajes o chalecos, lo que se conoce como electroestimulaci&oacute;n de cuerpo completo (en ingl&eacute;s, <i>whole body electromyostimulation</i> &#091;WB-EMS&#093;). Este tipo de entrenamiento<sup>12</sup> permite estimular simult&aacute;neamente hasta 14-18 regiones corporales (ambos muslos, ambos brazos, nalgas, abdomen, pecho, zonas baja de la espalda, zona alta de la espalda, dorsal ancho y 4 opciones libres) con un &aacute;rea total de electrodos de 2800 cm<sup>2</sup>.</font></p>     <p><font face="Verdana" size="2">En los &uacute;ltimos 5 a&ntilde;os se han creado en Espa&ntilde;a m&aacute;s de 500 centros de entrenamiento que aplican WB-EMS a sus clientes, y la demanda de esta tecnolog&iacute;a va en aumento. Las casas que comercializan estos aparatos aseguran en sus p&aacute;ginas web que con este medio de entrenamiento "se consigue activar musculatura profunda", "10 minutos equivalen a 4 horas de pesas", "adelgaza", "quema grasas hasta 72 horas despu&eacute;s de un entrenamiento", "mejora la fuerza, el salto vertical, la resistencia y tonifica", "es el primer sistema que mejora la velocidad en atletas de &eacute;lite" y "comprobado cient&iacute;ficamente"<sup>13-15</sup>. Sin embargo, en estos sitios web no se cita ning&uacute;n art&iacute;culo cient&iacute;fico serio que respalde estos mensajes. Como instituci&oacute;n comprometida con el entrenamiento basado en la evidencia, la <i>National Strength and Conditioning Association</i> &#091;NSCA&#093;-Spain publica este posicionamiento, cuyo prop&oacute;sito es revisar el estado del conocimiento sobre la metodolog&iacute;a del entrenamiento con WB-EMS sobre los efectos que tiene en el organismo y establecer si puede considerarse una forma de entrenamiento eficaz y segura.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Metodolog&iacute;a</b></font></p>     ]]></body>
<body><![CDATA[<p><i><font face="Verdana" size="2">B&uacute;squeda electr&oacute;nica y criterios de inclusi&oacute;n</font></i></p>     <p><font face="Verdana" size="2">Este art&iacute;culo se trata de una revisi&oacute;n sistem&aacute;tica, para la cual se ha realizado una b&uacute;squeda en las siguientes bases de datos: <i>PubMed</i> (desde 1951 hasta el presente), <i>Web of Science</i> (desde 1970 hasta el presente), <i>Physiotherapy Evidence Database</i> (PEDro) (desde 1929 hasta el presente) y Google acad&eacute;mico. Las combinaciones de t&eacute;rminos utilizadas en estas bases de datos fueron &#091;<i>Whole body</i> AND (<i>electrostimulation</i> OR <i>electromyostimulation</i>) OR <i>miha bodytec</i>&#093; en las 3 primeras bases de datos mencionadas, y &#091;<i>Whole body electrostimulation</i> OR <i>Whole body electromyostimulation</i> OR electroestimulaci&oacute;n de cuerpo completo OR electroestimulaci&oacute;n integral OR <i>miha bodytec</i>&#093; en Google acad&eacute;mico. La &uacute;ltima b&uacute;squeda electr&oacute;nica se realiz&oacute; el 23 de febrero de 2015. Las referencias citadas en los art&iacute;culos encontrados tambi&eacute;n fueron revisadas para localizar m&aacute;s estudios.</font></p>     <p><font face="Verdana" size="2">La lista de t&iacute;tulos y res&uacute;menes arrojada por la b&uacute;squeda fue analizada minuciosamente para seleccionar art&iacute;culos que cumpliesen los siguientes criterios de inclusi&oacute;n: a) aplicaci&oacute;n de WB-EMS de forma simult&aacute;nea en miembro superior y miembro inferior; b) proporcionar informaci&oacute;n sobre el protocolo de EMS aplicado, al menos para el grupo de intervenci&oacute;n, y c) incluir mediciones de la condici&oacute;n f&iacute;sica o de la composici&oacute;n corporal.</font></p>     <p><i><font face="Verdana" size="2">Extracci&oacute;n de datos</font></i></p>     <p><font face="Verdana" size="2">Los datos extra&iacute;dos fueron: tipo de art&iacute;culo, caracter&iacute;sticas de la muestra (tama&ntilde;o, sexo, edad, nivel de entrenamiento), protocolo de entrenamiento (duraci&oacute;n del estudio, sesiones totales, sesiones por semana, contracciones por sesi&oacute;n, duraci&oacute;n de la sesi&oacute;n, n&uacute;mero de grupos musculares entrenados), par&aacute;metros de la corriente (electroestimulador, tipo de corriente, ancho de impulso, frecuencia, tiempo de contracci&oacute;n, tiempo de reposo, <i>duty cyle</i>, intensidad) y principales resultados.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Resultados</b></font></p>     <p><i><font face="Verdana" size="2">Selecci&oacute;n de estudios</font></i></p>     <p><font face="Verdana" size="2">Los diferentes pasos de la b&uacute;squeda electr&oacute;nica se resumen en la <a href="#f1">figura 1</a>. Se identificaron un total de 96 art&iacute;culos con los par&aacute;metros de b&uacute;squeda anteriormente indicados. Tras eliminar los art&iacute;culos que aparec&iacute;an por duplicado, quedaron 54. Se leyeron detalladamente el t&iacute;tulo y el resumen para eliminar aquellos que no cumpl&iacute;an los criterios de inclusi&oacute;n. Finalmente, 2 res&uacute;menes<sup>16,17</sup> y 2 estudios de caso<sup>18,19</sup> fueron excluidos por no aportar datos suficientes sobre los protocolos de entrenamiento aplicados, y otros 2 no se incluyeron por tratarse de revisiones sistem&aacute;ticas<sup>3,20</sup>. Tambi&eacute;n se excluyeron 4 observaciones no publicadas<sup>21-24</sup>, una contribuci&oacute;n a un congreso<sup>25</sup> y una publicaci&oacute;n de divulgaci&oacute;n cient&iacute;fica<sup>26</sup>. De los 9 estudios originales que se incluyen en esta revisi&oacute;n, 8 eval&uacute;an efectos cr&oacute;nicos y uno, efectos agudos.</font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="center"><font face="Verdana" size="2"><a name="f1"><img src="/img/revistas/ramd/v8n4/articulo_especial_f1.jpg"></a>    <br><b>Figura 1.</b> Diagrama de flujo de la estrategia de b&uacute;squeda de art&iacute;culos.</font></p>     <p>&nbsp;</p>     <p><i><font face="Verdana" size="2">Estudios incluidos</font></i></p>     <p><font face="Verdana" size="2">En la <a target="_blank" href="/img/revistas/ramd/v8n4/articulo_especial_t1.jpg">tabla 1</a> se resumen las caracter&iacute;sticas de los 8 estudios que evaluaron los efectos cr&oacute;nicos de la aplicaci&oacute;n de WB-EMS, as&iacute; como del estudio que evalu&oacute; efectos agudos<sup>27</sup>. Pese a que en la <a target="_blank" href="/img/revistas/ramd/v8n4/articulo_especial_t1.jpg">tabla 1</a> se muestran 9 estudios, todos los datos corresponden &uacute;nicamente a 4 fases experimentales diferentes. Tres de estas fases experimentales son llamadas por los autores TEST-I, TEST-II y TEST-III, correspondiendo a fases de efectos cr&oacute;nicos. La cuarta fase corresponde al estudio de efectos agudos. Se aprecian diferentes publicaciones duales, puesto que 3 art&iacute;culos publicados en alem&aacute;n<sup>28-30</sup> est&aacute;n publicados en ingl&eacute;s con exactamente los mismos datos<sup>12,31,32</sup>. Adem&aacute;s, 2 estudios de Kemmler et al.<sup>31,33</sup> son id&eacute;nticos, con la diferencia de que en el primero de ellos solamente se analizaron los datos de los sujetos cuya circunferencia de cintura era superior a 80 cm en el pretest. Respecto a los participantes, los estudios de efectos cr&oacute;nicos han sido llevados a cabo en personas de m&aacute;s de 60 a&ntilde;os, generalmente en mujeres posmenop&aacute;usicas con osteopenia y osteoporosis (TEST-I y TEST-III). En 2 fases experimentales participaron sujetos sedentarios (TEST-II y TEST-III), mientras que en otras 2 participaron sujetos acostumbrados a entrenar (TEST-I y el estudio de Kemmler et al.<sup>27</sup>).</font></p>     <p><i><font face="Verdana" size="2">Protocolos de entrenamiento</font></i></p>     <p><font face="Verdana" size="2">Puesto que todos los estudios publicados sobre efectos cr&oacute;nicos se basan en 3 fases experimentales (TEST-I, TEST-II y TEST-III), la <a target="_blank" href="/img/revistas/ramd/v8n4/articulo_especial_t2.jpg">tabla 2</a> resume las principales caracter&iacute;sticas de los protocolos de entrenamiento con WB-EMS aplicados en ellas. En el TEST-I todos los sujetos realizaron 2 sesiones de entrenamiento en grupo supervisadas (60-65 min) y 2 sesiones de entrenamiento en casa (20-25 min) por semana<sup>34</sup>. Estas sesiones incluyeron ejercicio aer&oacute;bico, saltos multilaterales y ejercicios de fuerza (1-3 series, 6-12 repeticiones, 70-85% 1RM). Adem&aacute;s de esto, el grupo experimental realiz&oacute; un entrenamiento con WB-EMS en el que se ejecutaron 15 ejercicios din&aacute;micos con peque&ntilde;os rangos de movimiento<sup>34</sup>. En el TEST-II el grupo experimental llev&oacute; a cabo un entrenamiento de fuerza consistente en 5-7 ejercicios (2 series, 8-10 repeticiones) con WB-EMS superpuesta<sup>28</sup>. En este estudio el grupo control ejecut&oacute; ejercicios de estiramiento (6 ejercicios, 2 series, 40-60 s por repetici&oacute;n) sobre plataformas vibratorias en sesiones de 18 min con una frecuencia de 30 Hz, una amplitud de 1.7 mm y una aceleraci&oacute;n de 1.3 a 2.2 g<sup>28</sup>.</font></p>     <p><font face="Verdana" size="2">Finalmente, en el TEST-III el grupo experimental realiz&oacute; en cada sesi&oacute;n 10-14 ejercicios din&aacute;micos sin carga adicional (1-2 series de 8 repeticiones); la velocidad y la intensidad de estos ejercicios fueron consideradas bajas<sup>31</sup>. El grupo control entren&oacute; durante 2 periodos de 10 semanas, separados por otras 10 semanas entre medias, a raz&oacute;n de una sesi&oacute;n de 60 min por semana. Este grupo realiz&oacute; los mismos ejercicios de fuerza que el grupo experimental (8-10 ejercicios, 2 series, 8 repeticiones)<sup>31</sup>.</font></p>     <p><i><font face="Verdana" size="2">Par&aacute;metros de la electroestimulaci&oacute;n de cuerpo completo</font></i></p>     <p><font face="Verdana" size="2">En todos los estudios consultados se utiliz&oacute; el mismo aparato de entrenamiento (MIHA bodytec<sup>&reg;</sup>, Augsburgo, Alemania), que administra una onda bipolar. El ancho de impulso utilizado fue siempre 350 &#x3BC;s. Dos estudios aplicaron 2 corrientes distintas durante la misma fase experimental<sup>28,34</sup>, mientras que otros 2 estudios aplicaron una &uacute;nica corriente<sup>27,31</sup>. En el TEST-I se aplicaron 2 corrientes diferentes: una de 85 Hz y otra de 7 Hz durante 10 min cada una<sup>34</sup>. En el resto de estudios se aplic&oacute; una corriente de 85 Hz. Los tiempos de contracci&oacute;n oscilaron entre 4 y 6 s, mientras que los tiempos de reposo fueron siempre de 4 s. El tiempo de rampa en todos los estudios fue cero. El <i>duty cycle</i>, que es la relaci&oacute;n entre el tiempo de contracci&oacute;n y el tiempo de un ciclo contracci&oacute;n-reposo, oscil&oacute; entre el 50 y el 60%. Finalmente, para expresar la intensidad del entrenamiento varios estudios utilizaron una escala de esfuerzo percibido (RPE), solicitando a los sujetos que alcanzasen una intensidad entre "algo duro" y "duro"<sup>28,29,31,34</sup>. En el estudio de efectos agudos, la intensidad administrada fue la m&aacute;xima tolerada por los sujetos<sup>27</sup>.</font></p>     ]]></body>
<body><![CDATA[<p><i><font face="Verdana" size="2">Principales resultados</font></i></p>     <p><i><font face="Verdana" size="2">Gasto cal&oacute;rico</font></i></p>     <p><font face="Verdana" size="2">A nivel agudo, una sesi&oacute;n de entrenamiento con WB-EMS en varones j&oacute;venes (26.3 a&ntilde;os), en comparaci&oacute;n con la misma sesi&oacute;n de entrenamiento con el traje de WB-EMS puesto pero sin administrar corriente, supuso un gasto cal&oacute;rico un 17% mayor (412 &plusmn; 60 kcal&middot;h<sup>-1</sup> respecto a 352 &plusmn; 70 kcal&middot;h<sup>-1</sup>, p &lt; 0,01)<sup>27</sup>. Sin embargo, tras un periodo de entrenamiento de 14 semanas con WB-EMS el gasto cal&oacute;rico en reposo no se modific&oacute;, aconteciendo lo mismo en el grupo control (GE: -0.2%, GC: -5.3%)<sup>34</sup>.</font></p>     <p><i><font face="Verdana" size="2">Composici&oacute;n corporal</font></i></p>     <p><font face="Verdana" size="2">Tras un programa de entrenamiento con WB-EMS la masa muscular aument&oacute; en las 3 fases experimentales (TEST-I, TEST-II y TEST-III) respecto al grupo control<sup>28,31-34</sup>. En el TEST-I la masa muscular fue evaluada indirectamente mediante el consumo metab&oacute;lico en reposo determinado por calorimetr&iacute;a indirecta<sup>34</sup>. En el TEST-II y en el TEST-III la masa muscular se evalu&oacute; mediante absorciometr&iacute;a dual de rayos X<sup>28,31</sup>. La circunferencia de cintura disminuy&oacute;, no as&iacute; la circunferencia de cadera<sup>34</sup>. La suma de pliegues cut&aacute;neos<sup>34</sup> y la masa grasa total<sup>28</sup> disminuyeron en 2 fases experimentales (TEST-I y TEST-II), no as&iacute; en el TEST-III, en donde tampoco se modific&oacute; la masa grasa abdominal<sup>31</sup>. Sin embargo, si en el TEST-III se analizan &uacute;nicamente los datos de las personas que ten&iacute;an una circunferencia de cintura inicial superior a 80 cm, la masa grasa abdominal y del muslo disminuyeron<sup>33</sup>. La densidad mineral &oacute;sea tampoco se modific&oacute; respecto al grupo control tras 54 semanas de entrenamiento<sup>12</sup>.</font></p>     <p><i><font face="Verdana" size="2">Fuerza m&aacute;xima</font></i></p>     <p><font face="Verdana" size="2">El entrenamiento con WB-EMS fue capaz de mejorar la fuerza m&aacute;xima de los extensores del tronco, de los extensores de la rodilla y de prensi&oacute;n manual, respecto a los grupos control (<a target="_blank" href="/img/revistas/ramd/v8n4/articulo_especial_t4.jpg">tabla 4</a>).</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Discusi&oacute;n</b></font></p>     <p><font face="Verdana" size="2">Esta revisi&oacute;n muestra que actualmente hay un n&uacute;mero de estudios muy reducido sobre el entrenamiento con WB-EMS. La primera referencia a la WB-EMS data de 2002<sup>23</sup>, si bien el primer art&iacute;culo publicado en una revista indexada en ISI-JCR apareci&oacute; en 2010<sup>34</sup>. Por tanto, la WB-EMS es un medio de entrenamiento muy reciente cuya pr&aacute;ctica se ha extendido enormemente antes de que existan evidencias cient&iacute;ficas sobre sus efectos, ya sean favorables o adversos.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">Los participantes de la mayor&iacute;a de los estudios revisados fueron personas mayores con osteopenia, osteoporosis<sup>31,34</sup> o s&iacute;ndrome metab&oacute;lico<sup>28</sup>. La validez externa de los estudios analizados es, por tanto, reducida y no deber&iacute;an generalizarse los resultados a otras poblaciones. Por otro lado, la validez interna de los estudios analizados hay que valorarla con cierta cautela. En el TEST-I<sup>34</sup> el grupo experimental realiza el mismo programa de ejercicio que el grupo control m&aacute;s las sesiones de entrenamiento con WB-EMS, por lo que la carga de entrenamiento es desigual en ambos grupos. En el TEST-II<sup>28</sup> el grupo experimental realiza un programa de ejercicios de fuerza con WB-EMS superpuesta, mientras que el grupo control realiza ejercicios de estiramiento sobre una plataforma vibratoria. En el TEST-III<sup>31</sup> el grupo experimental entrena durante 54 semanas en sesiones de 19 min, mientras que el grupo control hace 2 bloques de entrenamiento de 10 semanas en sesiones de 60 min. Por tanto, ninguno de los estudios tiene un grupo control que permita discernir si es el programa de ejercicios realizado durante las sesiones de WB-EMS o la propia corriente lo que produce las adaptaciones observadas. Tambi&eacute;n llama la atenci&oacute;n que, trat&aacute;ndose de personas sedentarias no acostumbradas a entrenar<sup>28,31</sup>, no se mencione en los art&iacute;culos que los sujetos realizasen sesiones de familiarizaci&oacute;n con las pruebas de valoraci&oacute;n de la fuerza muscular. Se ha descrito que en hombres y mujeres sedentarios con una media de edad de 63 a&ntilde;os es necesario llevar a cabo al menos 3 sesiones de familiarizaci&oacute;n para tener una medida fiable de la fuerza muscular<sup>35</sup>.</font></p>     <p><font face="Verdana" size="2">En los estudios analizados el protocolo de WB-EMS habitual consisti&oacute; en 3 sesiones cada 2 semanas, con una duraci&oacute;n de entre 20-30 min en las que se aplic&oacute; una corriente de 85 Hz con una ratio contracci&oacute;n-reposo de 4-4 o 6-4 s (tablas <a target="_blank" href="/img/revistas/ramd/v8n4/articulo_especial_t2.jpg">2</a> y <a target="_blank" href="/img/revistas/ramd/v8n4/articulo_especial_t3.jpg">3</a>). La corriente se aplica en 8-10 regiones corporales de forma simult&aacute;nea, mientras los sujetos realizan ejercicios din&aacute;micos de fortalecimiento. En la revisi&oacute;n sistem&aacute;tica de Filipovic et al.<sup>3</sup> se indica que la EMS local ha sido capaz de aumentar la fuerza m&aacute;xima isom&eacute;trica desde un 22% hasta un 58% y la fuerza m&aacute;xima din&aacute;mica desde un 3% hasta un 79%. Respecto a la WB-EMS, los mayores incrementos constatados de fuerza m&aacute;xima isom&eacute;trica son del 9%<sup>3</sup> o del 15%<sup>28</sup>, y los de fuerza m&aacute;xima din&aacute;mica, del 14%<sup>3</sup>. Las razones por las cuales la WB-EMS es menos efectiva para mejorar la fuerza m&aacute;xima que la EMS local podr&iacute;an ser:</font></p>     <blockquote>     <p><font face="Verdana" size="2">a) La EMS local se suele aplicar de forma isom&eacute;trica, por lo que la fuerza muscular evocada por la corriente es mucho mayor (59% de la m&aacute;xima contracci&oacute;n voluntaria de media en los 35 art&iacute;culos analizados en Filipovic et al.<sup>20</sup>); con WB-EMS, al entrenarse de forma din&aacute;mica, no hay posibilidad de cuantificar la intensidad de la contracci&oacute;n.</font></p>     <p><font face="Verdana" size="2">b) La fuerza de la contracci&oacute;n depende de la intensidad de corriente tolerada y las adaptaciones al entrenamiento dependen, a su vez, de la fuerza de la contracci&oacute;n<sup>4</sup>; cuando un m&uacute;sculo est&aacute; acortado, por ejemplo cuando se entrena de forma din&aacute;mica con WB-EMS, la intensidad tolerada no es muy elevada, ya que el dolor percibido aumenta considerablemente, limit&aacute;ndose el reclutamiento de unidades motrices<sup>36</sup>.</font></p>     <p><font face="Verdana" size="2">c) En la EMS local el <i>duty cycle</i> habitual suele ser del 16.7 o del 23.8%, mientras que en la WB-EMS suele ser del 50 o del 60%; cuanto mayor es el <i>duty cycle</i>, mayor es la fatiga muscular y, en consecuencia, la fuerza generada por la corriente decae r&aacute;pidamente<sup>37</sup>; en el entrenamiento con EMS isom&eacute;trica se ha establecido un <i>duty cycle</i> &oacute;ptimo en torno al 20%<sup>37,38</sup>.</font></p>     <p><font face="Verdana" size="2">d) Cuanto mayor es la frecuencia utilizada, mayor es la fatiga muscular producida<sup>39</sup>; por encima de 70 Hz la fuerza muscular no incrementa sustancialmente, pero s&iacute; lo hace la fatiga<sup>39</sup>; por tanto, los 85 Hz habituales que se utilizan con WB-EMS, teniendo en cuenta el elevado <i>duty cycle</i>, quiz&aacute; sean demasiado elevados y podr&iacute;a resultar m&aacute;s interesante aplicar corrientes de 50 Hz, tambi&eacute;n utilizadas para mejorar la fuerza con EMS<sup>1,20</sup>.</font></p>     <p><font face="Verdana" size="2">e) Con EMS local la colocaci&oacute;n de los electrodos es m&aacute;s precisa, pues estos se ubican sobre los puntos motores de la musculatura a entrenar. Esta colocaci&oacute;n de electrodos hace que la corriente sea m&aacute;s c&oacute;moda de tolerar y maximiza el reclutamiento espacial de unidades motrices, haciendo que la fuerza generada por la contracci&oacute;n sea mayor<sup>40</sup>.</font></p> </blockquote>     <p><font face="Verdana" size="2">Si a todo lo expuesto se a&ntilde;ade que diferentes revisiones llegan a la conclusi&oacute;n de que el entrenamiento tradicional es m&aacute;s efectivo para incrementar la fuerza muscular en sujetos sanos que la electroestimulaci&oacute;n<sup>1,2</sup>, se puede intuir que la WB-EMS es un medio poco eficaz para la mejora de la fuerza muscular.</font></p>     <p><font face="Verdana" size="2">El estudio de Kemmler et al.<sup>27</sup> sobre el gasto cal&oacute;rico tiene un dise&ntilde;o experimental muy robusto. Adem&aacute;s de ser un dise&ntilde;o cruzado aleatorio, en la situaci&oacute;n control los participantes realizaban los mismos ejercicios que en la situaci&oacute;n experimental, con el chaleco puesto pero sin administrarse corriente para equiparar el nivel de sudoraci&oacute;n. Este estudio muestra que una sesi&oacute;n de 16 min con WB-EMS genera un gasto cal&oacute;rico de 412 &plusmn; 60 kcal&middot;h<sup>-1</sup>, lo que supone un mayor consumo que la situaci&oacute;n control (352 &plusmn; 70 kcal&middot;h<sup>-1</sup>, p &lt; 0,01). El autor expresa el gasto cal&oacute;rico por hora; teniendo en cuenta que la sesi&oacute;n dura 16 min, podemos calcular que el gasto cal&oacute;rico de una sesi&oacute;n de entrenamiento con WB-EMS es de 110 kcal, respecto a las 94 kcal de la misma sesi&oacute;n sin electroestimulaci&oacute;n. La diferencia en el n&uacute;mero de calor&iacute;as por sesi&oacute;n parece reducida, y aun as&iacute; surge la duda de si esta diferencia pudiera deberse a un incremento del metabolismo glucol&iacute;tico o lip&iacute;dico, pues la WB-EMS se oferta en los centros de entrenamiento como un sistema que adelgaza. En los estudios revisados encontramos casos en los que la WB-EMS fue efectiva para disminuir el porcentaje de grasa<sup>28,33,34</sup> y casos en los que no lo fue<sup>31</sup>. Como se ha comentado previamente, los dise&ntilde;os experimentales utilizados en estos estudios no permiten esclarecer si es la WB-EMS la causante de esta p&eacute;rdida de grasa. Adem&aacute;s, ninguno de los estudios revisados indica que se controlase la dieta de los participantes. Respecto a la EMS local, los niveles de ATP durante una sesi&oacute;n de entrenamiento de 45 min se mantienen constantes, principalmente por la depleci&oacute;n del gluc&oacute;geno muscular por v&iacute;a anaer&oacute;bica (primeros 15 min, aproximadamente) y por v&iacute;a aer&oacute;bica (del min 15 al 45, aproximadamente), contribuyendo de forma muy reducida a la producci&oacute;n de ATP los &aacute;cidos grasos libres<sup>41</sup>. Cuando se ha analizado la influencia de un programa de entrenamiento con EMS local sobre la grasa abdominal no se han observado modificaciones en los pliegues cut&aacute;neos valorados mediante t&eacute;cnicas cineantropom&eacute;tricas<sup>42,43</sup> o mediante ultrasonidos y rayos X<sup>44</sup>, ni en el porcentaje de grasa corporal<sup>42,45</sup>. En los estudios que han aplicado WB-EMS, en el mejor de los casos el porcentaje de grasa corporal total y abdominal disminuyeron un 6.3 y un 6.8%, respectivamente, tras 14 semanas de entrenamiento<sup>31</sup>, cuando una combinaci&oacute;n de ejercicio aer&oacute;bico y dieta durante 8 semanas en mujeres con sobrepeso es capaz de disminuir el porcentaje de grasa corporal un 11% y el tejido adiposo abdominal subcut&aacute;neo superficial un 32%<sup>46</sup>. Por lo tanto, no existen evidencias cient&iacute;ficas consistentes que indiquen que la WB-EMS disminuya la grasa corporal, y las evidencias que existen respecto a la EMS local demuestran que no la reduce.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">El principal autor de los trabajos revisados sobre WB-EMS se&ntilde;ala como limitaciones de este medio<sup>32</sup>: a) el elevado coste de la tecnolog&iacute;a subyacente (&#x7E; 10 000 &#x20ac; el sistema, m&aacute;s &#x7E; 1000 &#x20ac; anuales en concepto de mantenimiento de chalecos y electrodos); b) necesidad de un supervisor de manera continua, y c) est&aacute; contraindicado para personas con epilepsia, marcapasos cardiaco, trastornos circulatorios graves, hernia de abdomen o inguinal, tuberculosis, c&aacute;ncer, perturbaciones neurol&oacute;gicas graves, enfermedades inflamatorias, tendencia a sangrados, piel irritada, heridas, quemaduras y enfermedades que afecten al metabolismo muscular (p. ej., diabetes). Adem&aacute;s de estas limitaciones, bajo nuestro punto de vista existen otras, que describimos a continuaci&oacute;n.</font></p>     <p><font face="Verdana" size="2">En la EMS local la corriente circula a trav&eacute;s del m&uacute;sculo que se desea entrenar, coloc&aacute;ndose los electrodos sobre &eacute;l. Sin embargo, los chalecos de WB-EMS tienen los polos positivo y negativo de un mismo cable en diferentes lados de la l&iacute;nea media del cuerpo<sup>47</sup>. Esto implica que la corriente va de la zona pectoral, abdominal, dorsal y lumbar derecha a la respectiva zona izquierda. En el caso de los brazos y de las piernas, el polo positivo est&aacute; en un brazo y el negativo en el otro, por lo que la corriente va de un brazo y de una pierna al miembro contralateral. Cuando la corriente viaja a trav&eacute;s de nuestro organismo se propaga por los tejidos que menos resistencia ofrecen y, teniendo en cuenta que se est&aacute; estimulando la zona pectoral y dorsal a la vez, se crea un campo el&eacute;ctrico a trav&eacute;s de la caja tor&aacute;cica que podr&iacute;a interferir con la funci&oacute;n de &oacute;rganos vitales como el coraz&oacute;n<sup>48</sup>. Curiosamente, varias empresas tradicionales del &aacute;mbito de la fisioterapia indican textualmente en los manuales de sus aparatos "no utilizar los 2 polos de un mismo canal a ambos lados de la l&iacute;nea media del cuerpo"<sup>49</sup>, o "no deben colocarse los electrodos de manera que apliquen corriente a trav&eacute;s del t&oacute;rax, podr&iacute;a causar arritmias cardiacas"<sup>50</sup>. Por lo tanto, se recomienda prudencia a la hora de aplicar este tipo de corrientes hasta que se esclarezcan sus efectos org&aacute;nicos.</font></p>     <p><font face="Verdana" size="2">Respecto a sus efectos sobre el sistema musculoesquel&eacute;tico, se han publicado 2 estudios de caso en los que se diagnostic&oacute; rabdomiolisis tras una sesi&oacute;n de 15-20 min con WB-EMS<sup>18,19</sup>. En el primero de ellos, un jugador de f&uacute;tbol de 19 a&ntilde;os alcanz&oacute; unos valores de concentraci&oacute;n plasm&aacute;tica de creatincinasa (CK) de 240 000 U/l, y otro jugador de f&uacute;tbol, de 17 a&ntilde;os, alcanz&oacute; valores de 30 170 U/l<sup>19</sup>. En el segundo estudio se registr&oacute; una CK de 99 477 en una mujer sedentaria de 32 a&ntilde;os<sup>18</sup>. La elevaci&oacute;n de la CK por encima de 5000 U/l (valores normales &lt; 370 U/l) est&aacute; asociada, aunque no necesariamente, al s&iacute;ndrome compartimental, insuficiencia renal aguda, arritmias y paro cardiaco<sup>51,52</sup>, requiri&eacute;ndose una hospitalizaci&oacute;n inmediata del sujeto. En la literatura cient&iacute;fica solo hemos encontrado un caso de rabdomi&oacute;lisis con EMS local, en el cual un var&oacute;n de 26 a&ntilde;os present&oacute; unos valores de CK de 2917 U/l tras utilizar un aparato de EMS en la musculatura abdominal<sup>53</sup>. La primera raz&oacute;n por la cual la WB-EMS genera tal da&ntilde;o muscular puede estar relacionada con la aplicaci&oacute;n de intensidades de corriente elevadas (umbral del m&aacute;ximo dolor) a m&uacute;sculos que se est&aacute;n elongando, lo que podr&iacute;a causar da&ntilde;os mec&aacute;nicos en los tejidos. La segunda raz&oacute;n podr&iacute;a estar relacionada con la combinaci&oacute;n del patr&oacute;n de reclutamiento de las unidades motrices (espacialmente constante y temporalmente sincr&oacute;nico)<sup>54</sup> y la elevada superficie de los electrodos (2800 cm<sup>2</sup>)<sup>12</sup>. La WB-EMS tambi&eacute;n podr&iacute;a generar da&ntilde;o muscular en el caso de que la corriente presentase componente galv&aacute;nico; es decir, que la onda de corriente no sea perfectamente bif&aacute;sica y compensada, aunque en teor&iacute;a en los aparatos de WB-EMS lo es. La &uacute;ltima raz&oacute;n podr&iacute;a estar relacionada con la aplicaci&oacute;n de corrientes sin tiempo de reposo. En este sentido, el sobreesfuerzo y los nuevos est&iacute;mulos de ejercicio se han identificado como 2 de las causas predisponentes a la rabdomiolisis<sup>52</sup>. La aplicaci&oacute;n de corrientes de cuerpo completo sin tiempos de reposo cumple con ambos preceptos. Pese a que no se indica detalladamente c&oacute;mo entrenaron estas 3 personas<sup>18,19</sup>, se han descrito en la literatura aplicaciones de corrientes de 85 Hz de manera continua durante 15 min<sup>28</sup>, algo que se replica hoy en d&iacute;a en determinados centros de entrenamiento con WB-EMS. Adem&aacute;s, mediante EMS local se ha demostrado que al aplicar una corriente de 50 Hz durante 15 o 10 s al cu&aacute;driceps femoral, la fuerza producida por la musculatura deca&iacute;a dr&aacute;sticamente pasados 12.5 y 8.2 s, respectivamente<sup>55,56</sup>. En el caso del b&iacute;ceps braquial, aplicar una corriente de 50 Hz durante 10 s manten&iacute;a los niveles de fuerza al m&aacute;ximo durante 2 s, disminuyendo progresivamente la fuerza durante los siguientes 8 s<sup>57</sup>. De cara a buscar cierta funcionalidad en el est&iacute;mulo aplicado, tener durante 15 min 8 regiones corporales contra&iacute;das de forma simult&aacute;nea, adem&aacute;s de generar una tensi&oacute;n m&iacute;nima en la musculatura debido a la fatiga, no parece que tenga ninguna transferencia a alguna actividad de la vida diaria o actividad deportiva.</font></p>     <p><font face="Verdana" size="2">Otras limitaciones de la WB-EMS son: a) la imposibilidad de controlar la intensidad de la EMS; no se puede evaluar la fuerza ejercida por la musculatura ni ser&iacute;a adecuado hablar de umbral del m&aacute;ximo dolor, pues la tolerancia depende del grado de elongaci&oacute;n de la musculatura, y puesto que se entrena de forma din&aacute;mica, habr&iacute;a que estandarizar la posici&oacute;n de estimulaci&oacute;n inicial, y b) es un medio de entrenamiento que puede resultar doloroso, pues la estimulaci&oacute;n de nervios perif&eacute;ricos mediante corriente implica dolor, por lo que el cliente deber&iacute;a estar dispuesto a tolerarlo para entrenar.</font></p>     <p><font face="Verdana" size="2">En base a la revisi&oacute;n y al an&aacute;lisis realizados en el presente estudio, las conclusiones y recomendaciones que NSCA-Spain hace sobre la WB-EMS son:</font></p>     <blockquote>     <p><font face="Verdana" size="2">1. Es un medio de entrenamiento sobre el que se han realizado muy pocas investigaciones. Estas parecen indicar que es un medio poco eficaz para la mejora de la fuerza m&aacute;xima. El entrenamiento tradicional como primera opci&oacute;n, o la EMS local como segunda opci&oacute;n, son m&aacute;s eficaces para este prop&oacute;sito.</font></p>     <p><font face="Verdana" size="2">2. No hay evidencias suficientemente rigurosas que indiquen que disminuya la grasa corporal.</font></p>     <p><font face="Verdana" size="2">3. Se trata de un medio de entrenamiento muy reciente cuyos efectos colaterales sobre la salud se desconocen.</font></p>     <p><font face="Verdana" size="2">4. La relaci&oacute;n entre riesgo asumido y beneficio aportado hace que sean m&aacute;s recomendables otros medios de entrenamiento para la mejora de la fuerza muscular y para la modificaci&oacute;n de la composici&oacute;n corporal.</font></p> </blockquote>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Conflicto de intereses</b></font></p>     <p><font face="Verdana" size="2">Los autores declaran no tener ning&uacute;n conflicto de intereses.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Bibliograf&iacute;a</b></font></p>     <!-- ref --><p><font face="Verdana" size="2">1. Bax L, Staes F, Verhagen A. Does neuromuscular electrical stimulation strengthen the quadriceps femoris? A systematic review of randomised controlled trials. Sports Med. 2005;35:191-212.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444675&pid=S1888-7546201500040000400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">2. Dehail P, Duclos C, Barat M. Electrical stimulation and muscle strengthening. Ann Readapt Med Phys. 2008;51:441-51.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444677&pid=S1888-7546201500040000400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">3. Filipovic A, Kleinoder H, Dormann U, Mester J. Electromyostimulation: A systematic review of the effects of different electromyostimulation methods on selected strength parameters in trained and elite athletes. J Strength Cond Res. 2012;26:2600-14.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444679&pid=S1888-7546201500040000400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">4. Maffiuletti NA. Physiological and methodological considerations for the use of neuromuscular electrical stimulation. Eur J Appl Physiol. 2010;110:223-34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444681&pid=S1888-7546201500040000400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">5. Hortobagyi T, Maffiuletti NA. Neural adaptations to electrical stimulation strength training. Eur J Appl Physiol. 2011;111:2439-49.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444683&pid=S1888-7546201500040000400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">6. Vanderthommen M, Duchateau J. Electrical stimulation as a modality to improve performance of the neuromuscular system. Exerc Sport Sci Rev. 2007;35:180-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444685&pid=S1888-7546201500040000400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">7. Imoto AM, Peccin S, Almeida GJM, Saconato H, Atallah AN. Effectiveness of electrical stimulation on rehabilitation after ligament and meniscal injuries: A systematic review. Sao Paulo Med J. 2011;129:414-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444687&pid=S1888-7546201500040000400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">8. Kim KM, Croy T, Hertel J, Saliba S. Effects of neuromuscular electrical stimulation after anterior cruciate ligament reconstruction on quadriceps strength, function, and patient-oriented outcomes: A systematic review. J Orthop Sports Phys Ther. 2010;40:383-91.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444689&pid=S1888-7546201500040000400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">9. Kittelson AJ, Stackhouse SK, Stevens-Lapsley JE. Neuromuscular electrical stimulation after total joint arthroplasty: A critical review of recent controlled studies. Eur J Phys Rehabil Med. 2013;49:909-20.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444691&pid=S1888-7546201500040000400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">10. Maddocks M, Gao W, Higginson IJ, Wilcock A. Neuromuscular electrical stimulation for muscle weakness in adults with advanced disease. Cochrane Database Syst Rev. 2013;1:CD009419.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444693&pid=S1888-7546201500040000400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">11. Maffiuletti NA, Roig M, Karatzanos E, Nanas S. Neuromuscular electrical stimulation for preventing skeletal-muscle weakness and wasting in critically ill patients: A systematic review. BMC Med. 2013;11:137.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444695&pid=S1888-7546201500040000400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">12. Stengel S, Bebenek M, Engelke K, Kemmler W. Wholebody electromyostimulation to fight osteopenia in elderly females: The randomized controlled Training and Electrostimulation Trial (TEST-III). J Osteoporos. 2015;2015:643520.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444697&pid=S1888-7546201500040000400012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">13. Efit Spain (sede Web) (consultado 24 Feb 2015). Disponible en: <a target="_blank" href="http://www.efitspain.es">http://www.efitspain.es</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444699&pid=S1888-7546201500040000400013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">14. Mihabodytec (sede Web) (consultado 24 Feb 2015). Disponible en: <a target="_blank" href="http://mihabodytec.org/index.html">http://mihabodytec.org/index.html</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444701&pid=S1888-7546201500040000400014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">15. X-body (sede Web) (consultado 24 Feb 2015). Disponible en: <a target="_blank" href="http://www.xbodyworld.com/esp/">http://www.xbodyworld.com/esp/</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444703&pid=S1888-7546201500040000400015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">16. Kemmler W, von Stengel S, Mayhew J. Effects of whole-body-electromyostimulation on resting metabolic rate, anthropometric and neuromuscular parameters in the elderly. J Strength Cond Res. 2010;24:1880-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444705&pid=S1888-7546201500040000400016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">17. Schenk S, Fritzsche D, Buuren F. Electromyostimulation of skeletal muscles improves physical capacity of patients with chronic congestive heart failure. Thorac Cardiovasc Surg. 2011;59 Suppl 01:V218.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444707&pid=S1888-7546201500040000400017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">18. Finsterer J, Stollberger C. Severe rhabdomyolysis after MIHA-bodytec<sup>&reg;</sup> electrostimulation with previous mild hyper-CK-emia and noncompaction. Int J Cardiol. 2015;180:100-2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444709&pid=S1888-7546201500040000400018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">19. Kastner A, Braun M, Meyer T. Two cases of rhabdomyolysis after training with electromyostimulation by 2 young male professional soccer players. Clin J Sport Med. 2014, <a target="_blank" href="http://dx.doi.org/10.1097/JSM.0000000000000153">http://dx.doi.org/10.1097/JSM.0000000000000153</a> (Epub ahead of print).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444711&pid=S1888-7546201500040000400019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">20. Filipovic A, Kleinoder H, Dormann U, Mester J. Electromyostimulation: A systematic review of the influence of training regimens and stimulation parameters on effectiveness in electromyostimulation training of selected strength parameters. J Strength Cond Res. 2011;25:3218-38.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444713&pid=S1888-7546201500040000400020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">21. Boeckh-Behrens WU, Bengel M. Krafttraining durch elektromyostimulation? Empirische untersuchung zu den krafteffekten bei einem elektromyostimulationstraining am bodyTransformer mit variation der belastungsdichte (monograf&iacute;a en Internet). 2005 (consultado 23 Feb 2015). Disponible en: <a target="_blank" href="http://www.reizstrom-training.de/pdf/studie/Siebente-wissenschaftliche-Studie-mit-dem-BT.pdf">http://www.reizstrom-training.de/pdf/studie/Siebente-wissenschaftliche-Studie-mit-dem-BT.pdf</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444715&pid=S1888-7546201500040000400021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">22. Boeckh-Behrens WU, Mainka D. Krafttraining durch elektromyostimulation? Empirische untersuchung zu den krafteffekten bei einem elektomyostimulationstraining am bodyTransformer mit variation der trainingsdauer (monograf&iacute;a en Internet). 2006 (consultado 23 Feb 2015). Disponible en: <a target="_blank" href="http://www.reizstromtraining.de/pdf/studie/Neunte-wissenschaftliche-Studie-mit-dem-BT.pdf">http://www.reizstromtraining.de/pdf/studie/Neunte-wissenschaftliche-Studie-mit-dem-BT.pdf</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444717&pid=S1888-7546201500040000400022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">23. Boeckh-Behrens WU, Treu S. Vergleich der trainingseffekte von konventionellem krafttraining, maxxF und EMS-Training in den bereichen Kör-perzusammensetzung, Körperformung, Kraftentwicklung, Psyche und Befinden (monograf&iacute;a en Internet). 2002 (consultado 23 Feb 2015). Disponible en: <a target="_blank" href="http://www.reizstrom-training.de/pdf/studie/Dritte-wissentschaftliche-Studie-mit-dem-BT.pdf">http://www.reizstrom-training.de/pdf/studie/Dritte-wissentschaftliche-Studie-mit-dem-BT.pdf</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444719&pid=S1888-7546201500040000400023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">24. Boeckh-Behrens WU, Niewöhner F, Walz T. Ermittlung der trainingseffekte eines kombination trainings von konventionellem krafttraining und elektromyostimulationstraining. Universitat Bayreuth; 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444721&pid=S1888-7546201500040000400024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">25. Kreuzer S, Kleinöder H, Mester J. Effects of whole body electro stimulation training and traditional strength training on various strength and blood parameter in juvenile elite water polo players. Paper presented at: 11th annual Congress of the European College of Sport Science. Lausanne, Switzerland: ECSS; 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444723&pid=S1888-7546201500040000400025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">26. Speicher U, Kleinöder H. Effektivitätsprüfung klassischer und moderner krafttrainingsverfahren: differentielle kraftdiagnostik und moderne trainingsregulation. Wissenschaftsmagazin der Deutschen Sporthochschule Köln. 2009;14:20-2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444725&pid=S1888-7546201500040000400026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">27. Kemmler W, von Stengel S, Schwarz J, Mayhew JL. Effect of whole-body electromyostimulation on energy expenditure during exercise. J Strength Cond Res. 2012;26:240-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444727&pid=S1888-7546201500040000400027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">28. Kemmler W, Birlauf A, von Stengel S. Effects of whole-body-electromyostimulation on body composition and cardiac risk factors in elderly men with the metabolic syndrome. The TEST-II Study. Dtsch Z Sportmed. 2010; 61:117-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444729&pid=S1888-7546201500040000400028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">29. Kemmler W, Engelke K, von Stengel S. Effects of whole-body-electromyostimulation on sarcopenia in lean, elderly sedentary women. The TEST-III Study. Dtsch Z Sportmed. 2012;63:343.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444731&pid=S1888-7546201500040000400029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">30. Kemmler W, Bebenek M, von Stengel S. Effects of whole-body-electromyostimulation on bone mineral density in lean, sedentary elderly women with osteopenia. The randomized controlled TEST-III Study. Osteologie. 2013;22:121-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444733&pid=S1888-7546201500040000400030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">31. Kemmler W, Bebenek M, Engelke K, von Stengel S. Impact of whole-body electromyostimulation on body composition in elderly women at risk for sarcopenia: The Training and ElectroStimulation Trial (TEST-III). Age (Dordr). 2014;36:395-406.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444735&pid=S1888-7546201500040000400031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">32. Kemmler W, von Stengel S. Alternative exercise technologies to fight against sarcopenia at old age: A series of studies and review. J Aging Res. 2012;2012:109013.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444737&pid=S1888-7546201500040000400032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">33. Kemmler W, von Stengel S. Whole-body electromyostimulation as a means to impact muscle mass and abdominal body fat in lean, sedentary, older female adults: Subanalysis of the TEST-III trial. Clin Interv Aging. 2013;8:1353-64.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444739&pid=S1888-7546201500040000400033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">34. Kemmler W, Schliffka R, Mayhew JL, von Stengel S. Effects of whole-body electromyostimulation on resting metabolic rate, body composition, and maximum strength in postmenopausal women: The Training and ElectroStimulation Trial. J Strength Cond Res. 2010;24:1880-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444741&pid=S1888-7546201500040000400034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">35. Wallerstein LF, Barroso R, Tricoli V, Mello MT, Ugrinowitsch C. The influence of familiarization sessions on the stability of ramp and ballistic isometric torque in older adults. J Aging Phys Act. 2010;18:390-400.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444743&pid=S1888-7546201500040000400035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">36. Basas A. T&eacute;cnicas fisioter&aacute;picas aplicadas en el tratamiento de la patolog&iacute;a de la rodilla: Electroestimulaci&oacute;n neuromuscular. En: Basas A, Fern&aacute;ndez-Peñas C, Mart&iacute;n-Urrialde JA, editores. Tratamiento fisioter&aacute;pico de la rodilla. Madrid: McGraw-Hill/Interamericana; 2003. p. 64-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444745&pid=S1888-7546201500040000400036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">37. Ward AR, Robertson VJ, Ioannou H. The effect of duty cycle and frequency on muscle torque production using kilohertz frequency range alternating current. Med Engin Physics. 2004;26:569-79.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444747&pid=S1888-7546201500040000400037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">38. Liebano RE, Waszczuk S, Correa JB. The effect of burst-duty-cycle parameters of medium-frequency alternating current on maximum electrically induced torque of the quadriceps femoris, discomfort, and tolerated current amplitude in professional soccer players. J Orthop Sports Phys Ther. 2013;43:920-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444749&pid=S1888-7546201500040000400038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">39. Gregory CM, Dixon W, Bickel CS. Impact of varying pulse frequency and duration on muscle torque production and fatigue. Muscle Nerve. 2007;35:504-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444751&pid=S1888-7546201500040000400039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">40. Gobbo M, Maffiuletti NA, Orizio C, Minetto MA. Muscle motor point identification is essential for optimizing neuromuscular electrical stimulation use. J Neuroeng Rehabil. 2014;11:17.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444753&pid=S1888-7546201500040000400040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">41. Hultman E, Spriet LL. Skeletal-muscle metabolism, contraction force and glycogen utilization during prolonged electrical-stimulation in humans. J Physiol. 1986;374:493-501.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444755&pid=S1888-7546201500040000400041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">42. Porcari JP, McLean KP, Foster C, Kernozek T, Crenshaw B, Swenson C. Effects of electrical muscle stimulation on body composition, muscle strength, and physical appearance. J Strength Cond Res. 2002;16:165-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444757&pid=S1888-7546201500040000400042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">43. Porcari JP, Miller J, Cornwell K, Foster C, Gibson M, McLean K, et al. The effects of neuromuscular electrical stimulation training on abdominal strength, endurance, and selected anthropometric measures. J Sports Sci Med. 2005;4: 66-75.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444759&pid=S1888-7546201500040000400043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">44. Keller BA, Katch FI. Transcutaneous electrical muscle stimulation does not alter regional arm adiposity and muscularity. Am J Hum Biol. 1998;10: 317-26.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444761&pid=S1888-7546201500040000400044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">45. Anderson AG, Murphy MH, Murtagh E, Nevill A. An 8-week randomized controlled trial on the effects of brisk walking, and brisk walking with abdominal electrical muscle stimulation on anthropometric, body composition, and self-perception measures in sedentary adult women. Psychol Sport Exerc. 2006;7:437-51.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444763&pid=S1888-7546201500040000400045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">46. Fisher G, Hunter GR, Hyatt TC, Oster RA, Desmond RA, Gower BA. Effect of diet with and without exercise training on inflammation and fat distribution in overweight women. J Gen Intern Med. 2012;27:674-84.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444765&pid=S1888-7546201500040000400046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">47. miha bodytech GmbH. Miha bodytec User Manual. Augsburg (Alemania); 2011:9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444767&pid=S1888-7546201500040000400047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">48. Reed B. The physiology of neuromuscular electrical stimulation. Pediatr Phys Ther. 1997;9:96-102.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444769&pid=S1888-7546201500040000400048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">49. Compex Medical. Manual de utilizaci&oacute;n Compex 3. Ecublens (Suiza): Compex Medical SA; 2007:9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444771&pid=S1888-7546201500040000400049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">50. Enraf-Nonius. Serie 6. Manual de uso; 2014 (consultado 5 Mar 2015). Disponible en: http://www.enraf-nonius.com/docman-downloads/cat view/24-01-operating-manuals?limit=100&order=name&dir=DESC&start=115.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444773&pid=S1888-7546201500040000400050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">51. Khan FY. Rhabdomyolysis: A review of the literature. Neth J Med. 2009;67:272-83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444775&pid=S1888-7546201500040000400051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">52. Ramos DA, Dorgo S. Rhabdomyolysis: Considerations for recognition and prevention for practitioners. Strength Cond J. 2014;36:56-61.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444777&pid=S1888-7546201500040000400052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">53. Guarascio P, Lusi EA, Soccorsi F. Electronic muscular stimulators: A novel unsuspected cause of rhabdomyolysis. Br J Sports Med. 2004;38:505.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444779&pid=S1888-7546201500040000400053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">54. Bickel CS, Gregory CM, Dean JC. Motor unit recruitment during neuro-muscular electrical stimulation: A critical appraisal. Eur J Appl Physiol. 2011;111:2399-407.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444781&pid=S1888-7546201500040000400054&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">55. Selkowitz DM. Improvement in isometric strength of the quadriceps femoris muscle after training with electrical-stimulation. Phys Ther. 1985;65:186-96.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444783&pid=S1888-7546201500040000400055&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">56. Ward AR, Shkuratova N. Russian electrical stimulation: The early experiments. Phys Ther. 2002;82:1019-30.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444785&pid=S1888-7546201500040000400056&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>    <!-- ref --><p><font face="Verdana" size="2">57. Rich C, Cafarelli E. Submaximal motor unit firing rates after 8 wk of isometric resistance training. Med Sci Sports Exerc. 2000;32:190-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4444787&pid=S1888-7546201500040000400057&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="Verdana" size="2"><a href="#top"><img border="0" src="/img/revistas/ramd/v8n4/seta.gif" width="15" height="17"></a><a name="bajo"></a><b>Direcci&oacute;n para correspondencia:</b>    <br>Correo electr&oacute;nico: <a href="mailto:jaherrero@uemc.es">jaherrero@uemc.es</a>    <br>(A.J. Herrero).</font></p>     <p><font face="Verdana" size="2">Recibido el 18 de marzo de 2015    <br>Aceptado el 21 de mayo de 2015</font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bax]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Staes]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Verhagen]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Does neuromuscular electrical stimulation strengthen the quadriceps femoris?: A systematic review of randomised controlled trials]]></article-title>
<source><![CDATA[Sports Med.]]></source>
<year>2005</year>
<volume>35</volume>
<page-range>191-212</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dehail]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Duclos]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Barat]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical stimulation and muscle strengthening]]></article-title>
<source><![CDATA[Ann Readapt Med Phys.]]></source>
<year>2008</year>
<volume>51</volume>
<page-range>441-51</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Filipovic]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kleinoder]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Dormann]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Mester]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electromyostimulation: A systematic review of the effects of different electromyostimulation methods on selected strength parameters in trained and elite athletes]]></article-title>
<source><![CDATA[J Strength Cond Res.]]></source>
<year>2012</year>
<volume>26</volume>
<page-range>2600-14</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maffiuletti]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Physiological and methodological considerations for the use of neuromuscular electrical stimulation]]></article-title>
<source><![CDATA[Eur J Appl Physiol.]]></source>
<year>2010</year>
<volume>110</volume>
<page-range>223-34</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hortobagyi]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Maffiuletti]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neural adaptations to electrical stimulation strength training]]></article-title>
<source><![CDATA[Eur J Appl Physiol.]]></source>
<year>2011</year>
<volume>111</volume>
<page-range>2439-49</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vanderthommen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Duchateau]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical stimulation as a modality to improve performance of the neuromuscular system]]></article-title>
<source><![CDATA[Exerc Sport Sci Rev.]]></source>
<year>2007</year>
<volume>35</volume>
<page-range>180-5</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Imoto]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Peccin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Almeida]]></surname>
<given-names><![CDATA[GJM]]></given-names>
</name>
<name>
<surname><![CDATA[Saconato]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Atallah]]></surname>
<given-names><![CDATA[AN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effectiveness of electrical stimulation on rehabilitation after ligament and meniscal injuries: A systematic review]]></article-title>
<source><![CDATA[Sao Paulo Med J.]]></source>
<year>2011</year>
<volume>129</volume>
<page-range>414-23</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Croy]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hertel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Saliba]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of neuromuscular electrical stimulation after anterior cruciate ligament reconstruction on quadriceps strength, function, and patient-oriented outcomes: A systematic review]]></article-title>
<source><![CDATA[J Orthop Sports Phys Ther.]]></source>
<year>2010</year>
<volume>40</volume>
<page-range>383-91</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kittelson]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Stackhouse]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Stevens-Lapsley]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neuromuscular electrical stimulation after total joint arthroplasty: A critical review of recent controlled studies]]></article-title>
<source><![CDATA[Eur J Phys Rehabil Med.]]></source>
<year>2013</year>
<volume>49</volume>
<page-range>909-20</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maddocks]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gao]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Higginson]]></surname>
<given-names><![CDATA[IJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wilcock]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neuromuscular electrical stimulation for muscle weakness in adults with advanced disease]]></article-title>
<source><![CDATA[Cochrane Database Syst Rev.]]></source>
<year>2013</year>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maffiuletti]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Roig]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Karatzanos]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Nanas]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neuromuscular electrical stimulation for preventing skeletal-muscle weakness and wasting in critically ill patients: A systematic review]]></article-title>
<source><![CDATA[BMC Med.]]></source>
<year>2013</year>
<volume>11</volume>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bebenek]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Engelke]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wholebody electromyostimulation to fight osteopenia in elderly females: The randomized controlled Training and Electrostimulation Trial (TEST-III)]]></article-title>
<source><![CDATA[J Osteoporos.]]></source>
<year>2015</year>
<volume>2015</volume>
</nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="">
<collab>Efit Spain</collab>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="">
<collab>Mihabodytec</collab>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="">
<collab>X-body</collab>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mayhew]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of whole-body-electromyostimulation on resting metabolic rate, anthropometric and neuromuscular parameters in the elderly]]></article-title>
<source><![CDATA[J Strength Cond Res.]]></source>
<year>2010</year>
<volume>24</volume>
<page-range>1880-7</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schenk]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fritzsche]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Buuren]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electromyostimulation of skeletal muscles improves physical capacity of patients with chronic congestive heart failure]]></article-title>
<source><![CDATA[Thorac Cardiovasc Surg.]]></source>
<year>2011</year>
<volume>59</volume>
<numero>^s01</numero>
<issue>^s01</issue>
<supplement>01</supplement>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Finsterer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Stollberger]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Severe rhabdomyolysis after MIHA-bodytec® electrostimulation with previous mild hyper-CK-emia and noncompaction]]></article-title>
<source><![CDATA[Int J Cardiol.]]></source>
<year>2015</year>
<volume>180</volume>
<page-range>100-2</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kastner]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Braun]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Meyer]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Two cases of rhabdomyolysis after training with electromyostimulation by 2 young male professional soccer players]]></article-title>
<source><![CDATA[Clin J Sport Med.]]></source>
<year>2014</year>
</nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Filipovic]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kleinoder]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Dormann]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Mester]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electromyostimulation: A systematic review of the influence of training regimens and stimulation parameters on effectiveness in electromyostimulation training of selected strength parameters]]></article-title>
<source><![CDATA[J Strength Cond Res.]]></source>
<year>2011</year>
<volume>25</volume>
<page-range>3218-38</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boeckh-Behrens]]></surname>
<given-names><![CDATA[WU]]></given-names>
</name>
<name>
<surname><![CDATA[Bengel]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Krafttraining durch elektromyostimulation?: Empirische untersuchung zu den krafteffekten bei einem elektromyostimulationstraining am bodyTransformer mit variation der belastungsdichte]]></source>
<year>2005</year>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boeckh-Behrens]]></surname>
<given-names><![CDATA[WU]]></given-names>
</name>
<name>
<surname><![CDATA[Mainka]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Krafttraining durch elektromyostimulation?: Empirische untersuchung zu den krafteffekten bei einem elektomyostimulationstraining am bodyTransformer mit variation der trainingsdauer]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boeckh-Behrens]]></surname>
<given-names><![CDATA[WU]]></given-names>
</name>
<name>
<surname><![CDATA[Treu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Vergleich der trainingseffekte von konventionellem krafttraining, maxxF und EMS-Training in den bereichen Kör-perzusammensetzung, Körperformung, Kraftentwicklung, Psyche und Befinden]]></source>
<year>2002</year>
</nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boeckh-Behrens]]></surname>
<given-names><![CDATA[WU]]></given-names>
</name>
<name>
<surname><![CDATA[Niewöhner]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Walz]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[Ermittlung der trainingseffekte eines kombination trainings von konventionellem krafttraining und elektromyostimulationstraining]]></source>
<year>2003</year>
<publisher-name><![CDATA[Universitat Bayreuth]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kreuzer]]></surname>
</name>
<name>
<surname><![CDATA[Kleinöder]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Mester]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Effects of whole body electro stimulation training and traditional strength training on various strength and blood parameter in juvenile elite water polo players]]></source>
<year></year>
<conf-name><![CDATA[11 annual Congress of the European College of Sport Science]]></conf-name>
<conf-date>2006</conf-date>
<conf-loc>Lausanne </conf-loc>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Speicher]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Kleinöder]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="de"><![CDATA[Effektivitätsprüfung klassischer und moderner krafttrainingsverfahren: differentielle kraftdiagnostik und moderne trainingsregulation]]></article-title>
<source><![CDATA[Wissenschaftsmagazin der Deutschen Sporthochschule Köln]]></source>
<year>2009</year>
<volume>14</volume>
<page-range>20-2</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Schwarz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mayhew]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of whole-body electromyostimulation on energy expenditure during exercise]]></article-title>
<source><![CDATA[J Strength Cond Res.]]></source>
<year>2012</year>
<volume>26</volume>
<page-range>240-5</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Birlauf]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of whole-body-electromyostimulation on body composition and cardiac risk factors in elderly men with the metabolic syndrome: The TEST-II Study]]></article-title>
<source><![CDATA[Dtsch Z Sportmed.]]></source>
<year>2010</year>
<volume>61</volume>
<page-range>117-23</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Engelke]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of whole-body-electromyostimulation on sarcopenia in lean, elderly sedentary women: The TEST-III Study]]></article-title>
<source><![CDATA[Dtsch Z Sportmed.]]></source>
<year>2012</year>
<volume>63</volume>
<page-range>343</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Bebenek]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of whole-body-electromyostimulation on bone mineral density in lean, sedentary elderly women with osteopenia: The randomized controlled TEST-III Study]]></article-title>
<source><![CDATA[Osteologie]]></source>
<year>2013</year>
<volume>22</volume>
<page-range>121-8</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Bebenek]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Engelke]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impact of whole-body electromyostimulation on body composition in elderly women at risk for sarcopenia: The Training and ElectroStimulation Trial (TEST-III)]]></article-title>
<source><![CDATA[Age (Dordr)]]></source>
<year>2014</year>
<volume>36</volume>
<page-range>395-406</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alternative exercise technologies to fight against sarcopenia at old age: A series of studies and review]]></article-title>
<source><![CDATA[J Aging Res.]]></source>
<year>2012</year>
<volume>2012</volume>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Whole-body electromyostimulation as a means to impact muscle mass and abdominal body fat in lean, sedentary, older female adults: Subanalysis of the TEST-III trial]]></article-title>
<source><![CDATA[Clin Interv Aging]]></source>
<year>2013</year>
<volume>8</volume>
<page-range>1353-64</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemmler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Schliffka]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Mayhew]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[von Stengel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of whole-body electromyostimulation on resting metabolic rate, body composition, and maximum strength in postmenopausal women: The Training and ElectroStimulation Trial]]></article-title>
<source><![CDATA[J Strength Cond Res.]]></source>
<year>2010</year>
<volume>24</volume>
<page-range>1880-7</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wallerstein]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[Barroso]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Tricoli]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Mello]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
<name>
<surname><![CDATA[Ugrinowitsch]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of familiarization sessions on the stability of ramp and ballistic isometric torque in older adults]]></article-title>
<source><![CDATA[J Aging Phys Act.]]></source>
<year>2010</year>
<volume>18</volume>
<page-range>390-400</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Basas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Técnicas fisioterápicas aplicadas en el tratamiento de la patología de la rodilla: Electroestimulación neuromuscular]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Basas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández-Peñas]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Martín-Urrialde]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<source><![CDATA[Tratamiento fisioterápico de la rodilla]]></source>
<year>2003</year>
<page-range>64-5</page-range><publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill/Interamericana]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ward]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Robertson]]></surname>
<given-names><![CDATA[VJ]]></given-names>
</name>
<name>
<surname><![CDATA[Ioannou]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of duty cycle and frequency on muscle torque production using kilohertz frequency range alternating current]]></article-title>
<source><![CDATA[Med Engin Physics]]></source>
<year>2004</year>
<volume>26</volume>
<page-range>569-79</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liebano]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Waszczuk]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of burst-duty-cycle parameters of medium-frequency alternating current on maximum electrically induced torque of the quadriceps femoris, discomfort, and tolerated current amplitude in professional soccer players]]></article-title>
<source><![CDATA[J Orthop Sports Phys Ther.]]></source>
<year>2013</year>
<volume>43</volume>
<page-range>920-6</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gregory]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Dixon]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Bickel]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impact of varying pulse frequency and duration on muscle torque production and fatigue]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>2007</year>
<volume>35</volume>
<page-range>504-9</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gobbo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Maffiuletti]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Orizio]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Minetto]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Muscle motor point identification is essential for optimizing neuromuscular electrical stimulation use]]></article-title>
<source><![CDATA[J Neuroeng Rehabil.]]></source>
<year>2014</year>
<volume>11</volume>
<page-range>17</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hultman]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Spriet]]></surname>
<given-names><![CDATA[LL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Skeletal-muscle metabolism, contraction force and glycogen utilization during prolonged electrical-stimulation in humans]]></article-title>
<source><![CDATA[J Physiol.]]></source>
<year>1986</year>
<volume>374</volume>
<page-range>493-501</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Porcari]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[McLean]]></surname>
<given-names><![CDATA[KP]]></given-names>
</name>
<name>
<surname><![CDATA[Foster]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kernozek]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Crenshaw]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Swenson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of electrical muscle stimulation on body composition, muscle strength, and physical appearance]]></article-title>
<source><![CDATA[J Strength Cond Res.]]></source>
<year>2002</year>
<volume>16</volume>
<page-range>165-72</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Porcari]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cornwell]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Foster]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Gibson]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[McLean]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effects of neuromuscular electrical stimulation training on abdominal strength, endurance, and selected anthropometric measures]]></article-title>
<source><![CDATA[J Sports Sci Med.]]></source>
<year>2005</year>
<volume>4</volume>
<page-range>66-75</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Keller]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
<name>
<surname><![CDATA[Katch]]></surname>
<given-names><![CDATA[FI]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Transcutaneous electrical muscle stimulation does not alter regional arm adiposity and muscularity]]></article-title>
<source><![CDATA[Am J Hum Biol.]]></source>
<year>1998</year>
<volume>10</volume>
<page-range>317-26</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
<name>
<surname><![CDATA[Murphy]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Murtagh]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Nevill]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An 8-week randomized controlled trial on the effects of brisk walking, and brisk walking with abdominal electrical muscle stimulation on anthropometric, body composition, and self-perception measures in sedentary adult women]]></article-title>
<source><![CDATA[Psychol Sport Exerc.]]></source>
<year>2006</year>
<volume>7</volume>
<page-range>437-51</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fisher]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hunter]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Hyatt]]></surname>
<given-names><![CDATA[TC]]></given-names>
</name>
<name>
<surname><![CDATA[Oster]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Desmond]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Gower]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of diet with and without exercise training on inflammation and fat distribution in overweight women]]></article-title>
<source><![CDATA[J Gen Intern Med.]]></source>
<year>2012</year>
<volume>27</volume>
<page-range>674-84</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="">
<collab>miha bodytech</collab>
<source><![CDATA[Miha bodytec User Manual]]></source>
<year>2011</year>
<page-range>9</page-range><publisher-loc><![CDATA[Augsburg ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reed]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The physiology of neuromuscular electrical stimulation]]></article-title>
<source><![CDATA[Pediatr Phys Ther.]]></source>
<year>1997</year>
<volume>9</volume>
<page-range>96-102</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="book">
<collab>Compex Medical</collab>
<source><![CDATA[Manual de utilización Compex 3]]></source>
<year>2007</year>
<page-range>9</page-range><publisher-loc><![CDATA[Ecublens ]]></publisher-loc>
<publisher-name><![CDATA[Compex Medical]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="">
<collab>Enraf-Nonius</collab>
<source><![CDATA[Serie 6. Manual de uso]]></source>
<year>2014</year>
</nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[FY]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Rhabdomyolysis: A review of the literature]]></article-title>
<source><![CDATA[Neth J Med.]]></source>
<year>2009</year>
<volume>67</volume>
<page-range>272-83</page-range></nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramos]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Dorgo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Rhabdomyolysis: Considerations for recognition and prevention for practitioners]]></article-title>
<source><![CDATA[Strength Cond J.]]></source>
<year>2014</year>
<volume>36</volume>
<page-range>56-61</page-range></nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guarascio]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lusi]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Soccorsi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electronic muscular stimulators: A novel unsuspected cause of rhabdomyolysis]]></article-title>
<source><![CDATA[Br J Sports Med.]]></source>
<year>2004</year>
<volume>38</volume>
</nlm-citation>
</ref>
<ref id="B54">
<label>54</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bickel]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Gregory]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Dean]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Motor unit recruitment during neuro-muscular electrical stimulation: A critical appraisal]]></article-title>
<source><![CDATA[Eur J Appl Physiol.]]></source>
<year>2011</year>
<volume>111</volume>
<page-range>2399-407</page-range></nlm-citation>
</ref>
<ref id="B55">
<label>55</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Selkowitz]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improvement in isometric strength of the quadriceps femoris muscle after training with electrical-stimulation]]></article-title>
<source><![CDATA[Phys Ther.]]></source>
<year>1985</year>
<volume>65</volume>
<page-range>186-96</page-range></nlm-citation>
</ref>
<ref id="B56">
<label>56</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ward]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Shkuratova]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Russian electrical stimulation: The early experiments]]></article-title>
<source><![CDATA[Phys Ther.]]></source>
<year>2002</year>
<volume>82</volume>
<page-range>1019-30</page-range></nlm-citation>
</ref>
<ref id="B57">
<label>57</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rich]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Cafarelli]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Submaximal motor unit firing rates after 8 wk of isometric resistance training]]></article-title>
<source><![CDATA[Med Sci Sports Exerc.]]></source>
<year>2000</year>
<volume>32</volume>
<page-range>190-6</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
