SciELO - Scientific Electronic Library Online

 
vol.5 número2Masa auricular como complicación después de intervención coronaria percutánea compleja índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


REC: Interventional Cardiology

versión On-line ISSN 2604-7276versión impresa ISSN 2604-7306

REC Interv Cardiol ES vol.5 no.2 Madrid abr./jun. 2023  Epub 18-Mar-2024

https://dx.doi.org/10.24875/recic.m22000346 

IMAGES IN CARDIOLOGY

Implante percutáneo de válvula aórtica mediante co-registro FEops HEARTguide

Transcatheter aortic valve implantation using FEops HEARTguide co-registration

Transcatheter aortic valve implantation using FEops HEARTguide co-registration

Pablo J Antúnez-Muiñosa  b  *  , Sergio López-Tejeroa  b  , Jesús Herrero Garibia  b  , Elena Díaz Peláeza  b  c  , Pedro Luis Sánchez Fernándeza  b  c  , Ignacio Cruz-Gonzáleza  b  c 

aServicio de Cardiología, Hospital Universitario de Salamanca, Salamanca, España

bInstituto de Investigación Biomédica de Salamanca (IBSAL), Salamanca, España

cCentro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), España

Transcatheter aortic valve implantation (TAVI) success rate is very high and has a low rate of complications. Therefore, the number of TAVIs has been increasing worldwide. However, complications such as paravalvular leak (PVL) or permanent pacemaker implantation (PPMI) need still to be resolved, particularly in younger patients.

At this point, new technologies may help solve these problems. The FEops HEARTguide is a software that simulates the interaction between the device and patient’s anatomy (figure 1A,B). FEops provides the operator with different options and device sizes in a higher or deeper position (EVOLUT no. 26 and no. 29, Medtronic, United States), predicts the theoretical membranous septum, and the device contact pressure by analyzing the tissue characteristics of patient´s anatomy in the computed tomography (CT) images or risk of residual PVL or PPMI (figure 1C-H). Therefore, preoperative planning with FEops can be used to choose the most suitable size and device position for each patient.

Figure 1. 

On the other hand, synchronized co-registration CT-fluoro has proven useful during TAVI. This is the first case ever performed worldwide using FEops image co-registration with live fluoroscopy in a TAVI procedure (figure 2, video 1 of the supplementary data; red circle: marks the membranous septum). However, no live correlation with heart and lung movements is its main limitation.

Figure 2. 

In conclusion, FEops is potentially useful in TAVI not only for preoperative planning but also co-registration with fluoroscopy imaging during the procedure may reduce the complications associated with TAVI, especially in complex anatomies. Also, it can reduce the contrast used and the learning curve regarding difficult anatomies.

Written and oral informed consent were obtained before performing the procedure and for publication purposes.

AUTHORS’ CONTRIBUTIONS

All the authors participated in this manuscript, reviewed, and fully agreed on its content.

SUPPLEMENTARY DATA

Supplementary data associated with this article can be found in the online version available at https://doi.org/10.24875/RECICE.M22000349.

FUNDINGNone whatsoever.

Received: August 18, 2022; Accepted: October 10, 2022

Creative Commons License Sociedad Española de Cardiología. Publicado por Permanyer Publications. Este es un artículo open access bajo la licencia CC BY-NC-ND 4.0